Part No. F40BP74660000 Form No. BP7466 11/12 ETL Model No.: CF110 READ AND SA VE THESE INSTRUCTIONS CALLAN ™ 48” Ceiling F an Owner's Manual Model Numbers CF110BS00 - Br ushed Steel CF110ORB00 - Oil R ub bed Br onz e Net W eight: 23.
2 Safety Instructions TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a . Use this unit only in a manner intended by the manufacturer.
Unpacking Instructions 3 emersonfans.com Please contact 1-800-654-3545 for further assistance ETL Model No.: CF110 This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co.
Before assembly your ceiling fan, refer to section on proper method of wiring your fan (page 9). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.
5 emersonfans.com Please contact 1-800-654-3545 for further assistance ETL Model No.: CF110 1/4-20 x 1/2" FLANGE SCREWS WITH LOCKWASHERS PRE-ASSEMBLED (2) FLANGE/BLADE ASSEMBL Y MOTOR HUB Figure .
6 ETL Model No.: CF110 9. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 8). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in Step 14.
Electrical Requirements 7 emersonfans.com Please contact 1-800-654-3545 for further assistance ETL Model No.: CF110 Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
8 ETL Model No.: CF110 A T LEAST 7' FLOOR CEILING Figure 13 TWO SCREWS SUPPLIED WITH OUTLET BOX HANGER BRACKET TA B OUTLET BOX Figure 14 OUTLET BOX HANGER BRACKET HANGER BALL/ DOWNROD ASSEMBL Y NOTE: CEILING COVER, SUPPL Y WIRES AND F AN WIRES OMITTED FOR CLARITY .
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. 1. Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation).
10 ETL Model No.: CF110 This control is designed to operate only one ceiling fan, (Figure 18). This SW46 speed control is rated for 1.2 amps at 120 volts.. 1. Before disconnecting power, ensure that the fan is set at the highest speed. NOTE: Electric connections should be in accordance with the National Electrical Codes and all Local Codes.
11 emersonfans.com Please contact 1-800-654-3545 for further assistance ETL Model No.: CF110 8. Position the faceplate (provided) onto the SW46 speed control. Using the two 6-32 x 1/4” screws, screw the faceplate and speed control to the wall outlet box (Figure 21).
12 ETL Model No.: CF110 Repair Parts 4 9 8 1 5 2 3 6 14 15 16 17 7 22 4 0 3 2 1 13 18 19 11 21 20 12 10.
13 emersonfans.com Please contact 1-800-654-3545 for further assistance ETL Model No.: CF110 Repair Parts Listing Before discarding packaging material, be certain all parts have been removed.
14 ETL Model No.: CF110 Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock. WARNING ! IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed.
15 emersonfans.com Please contact 1-800-654-3545 for further assistance ETL Model No.: CF110 What The Limited Warranty Covers: This limited warranty is offered by Air Comfort Products division of Emerson Electric Co.
Questions, problems, missing parts: Before returning to the store call Emerson Electric Customer Service 8 a.m. - 6 p.m., EST , Monday-Friday 1-800-654-3545 www .emersonfans.com Retain this manual for future use. Air Comf or t Pr oducts DIVISION OF EMERSON ELECTRIC CO.
Een belangrijk punt na aankoop van elk apparaat Emerson CF110ORB00 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Emerson CF110ORB00 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Emerson CF110ORB00 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Emerson CF110ORB00 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Emerson CF110ORB00 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Emerson CF110ORB00 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Emerson CF110ORB00 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Emerson CF110ORB00 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.