Gebruiksaanwijzing /service van het product CF3600AP van de fabrikant Emerson
Ga naar pagina of 16
Part No. F40BP73840000 Form No. BP7384 Model No.: CF3600 READ AND SA VE THESE INSTRUCTIONS Net Weight: 15.9 Lbs. CAMDEN ™ 52” Damp Loca tion Ceiling F an Owner's Manual CF3600AP Antique P ewt.
WARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’ s manual carefully and keep it for future reference.
3 THIS F AN IS SUIT ABLE FOR DAMP LOCA TIONS SUCH AS COVERED PORCHES, COVERED P A TIOS, AND COVERED DECKS...ANYWHERE THERE IS A ROOF OVERHEAD. This Manual is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan Do not install or use fan if any part is damaged or missing.
4 2. Remove and discard the two cardboard shipping retainers securing the motor hub in the motor housing assembly . 3. Remove the fan motor assembly from the protective plastic bag. Place all carton contents on a protective surface. 4. Position the fan motor assembly , with the motor hub facing up, carefully on the styrofoam for blade assembly .
5 Y our new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
8. Carefully turn partially assembled fan over and place on top of the styrofoam, resting on switch cover assembly . 6 9. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 4). Remove the clevis pin from the downrod, then remove the hanger ball.
F AN MOTOR ASSEMBL Y DOWNROD MOTOR COVER #8-32 x 1/4" P AN HEAD SCREW (4) Figure 6 MOTOR COVER COUPLING COVER DOWNROD GROMMET CEILING COVER Figure 7 14. Make sure the grommet is properly installed in the coupling cover then slide the coupling cover over the downrod until it rests on the motor housing cover .
1. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 10). How to Hang Y our Ceiling F an The fan must be hung with at least 7' of clearance from floor to blades (Figure 9). ! WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs.
9 2. Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 1 1). Be sure the groove in the ball is lined up with the tab on the hanger bracket (Figure 10). Hanger bracket must seat firmly against outlet box.
3. Screw the two 1-1/4” threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 12). 4. Lift the ceiling cover up to the threaded studs and turn until the studs protrude through the holes in the ceiling cover (Figure 13).
11 Model No.: CF3600 1. Downrod Extension Kits (see store or catalog). 2. Blades (see store or catalog). Do not use water when cleaning your ceiling fan.
12 R epair Par ts 8 6 5 1 4 3 2 7 19 9 20 15 18 BLADE SETS SOLD SEP ARATEL Y 11 22 23 12 13 24 14 25 16 21 17 26 10 Before discarding packaging material, be certain all parts have been removed.
13 Part Numbers Key Model No. Model No. N o . Description CF3600AP00 CF3600ORH00 * Hanger Pack, Consisting of: 761655-80 761655-65 1 Hanger Bracket Assembly (1) — — 2 Hanger Ball (1) — — 3 Dow.
14 T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. WARNING: Make sure main power is turned off. 2. Loose power line 2. Check line power connections connections to the fan.
15 LIMITED WARRANTY What The W ar ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered.
Part No. F40BP73840000 Printed in China 01/09 Form No. BP7384 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W . Florissant • St. Louis, MO 63136 Model No.
Een belangrijk punt na aankoop van elk apparaat Emerson CF3600AP (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Emerson CF3600AP heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Emerson CF3600AP vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Emerson CF3600AP leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Emerson CF3600AP krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Emerson CF3600AP bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Emerson CF3600AP kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Emerson CF3600AP . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.