Part No. F40BP73330000 Form No. BP7333 UL Model No.: CF750 READ AND SA VE THESE INSTRUCTIONS Net Weight: 28.6 Lbs. MA Y A ZEN ™ 54” Ceiling Fan Owner's Manual CF750ORB00 Model No.
W ARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’s manual carefully and keep it for future reference.
3 This Manual is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan Do not install or use fan if any part is damaged or missing.
4 2. Remove and discard the two cardboard shipping retainers securing the motor hub in the motor housing assembly . 3. Remove the fan motor assembly from the protective plastic bag. Place all carton contents on a protective surface. J. HANGER BRACKET HI MED LOW FAN OFF EMERSON D/L U/L LIGHT A.
5 Y our new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
F AN MOTOR ASSEMBL Y 6 - 8 INCHES STYROFOAM P ACKAGING FLA T EDGE OF LIGHT KIT PLA TE ASSEMBL Y STYROFOAM M4 x 10mm SERRA TED HEAD SCREW (3) KEY HOLE SLOT (2) MOUNTING HOLE (1) LIGHT KIT ASSEMBL Y F A.
10. Unscrew and remove one lockwasher and screw from each end of the upper light plate cover on the fan motor housing. Do not remove the screw closest to the light holes (Figure 9). NOTE: The screw closest to the light holes, holds the light socket to the light plate cover .
8 CEILING COVER PIN DOWNROD HANGER BALL SETSCREW Figure 14 It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
1. Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box (Figure 16). How to Hang Y our Ceiling Fan The fan must be hung with at least 7' of clearance from floor to blades (Figure 15). ! W ARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs.
OUTLET BOX BLACK SUPPL Y WIRE BLACK/WHITE RECEIVER WIRE BLACK F AN WIRE BLUE F AN WIRE BLUE RECEIVER WIRE YELLOW F AN WIRE YELLOW RECEIVER WIRE CEILING COVER WHITE RECEIVER WIRE WHITE F AN WIRE WIRE C.
11 Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place.
5. Unscrew the finial nut, hex jamnut, and rubber lockwasher from the light kit threaded nipple (Figure 22). Retain the lockwasher , hex jamnut and finial nut for future installation. 6. Position the glass shade over the threaded nipple in the light kit plate assembly (Figure 23).
ON 1 234 RECEIVER SWITCH LEVERS CODE SWITCH SW105 RECEIVER CODE SWITCH WALL CONTROL WALL CONTROL LEVERS ON 1 234 LIGHT HI HI MED MED LOW LOW FAN OFF T urning off wall switch is not sufficient. T o avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box.
4. T o turn the lights on and off, press and release the upper part of the LIGHT (U/L) button or the lower part of the LIGHT (D/L) button. The lights will turn on at the light level previously set (see Step 3). Red light turns on when any button is pressed.
15 1. Downrod Extension Kits (see store or catalog). 2. Ceiling Fan Controls (see store or catalog). 3. Blades (see store or catalog). Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.
16 Repair Parts 4 24 HI MED LOW FAN OFF EMERSON D/L U/L LIGHT 29 1 7 8 9 6 3 2 15 16 17 28 5 21 22 25 13 14 23 18 30 10 27 26 11 12 20 19 BP7333 CF750 MAYA ZEN 12/22/06 7:59 AM Page 16.
Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REP AIR P ARTS, AL WA YS GIVE THE FOLLOWING INFORMA TION: The model number of your Fan will be found on a label attached to the top housing.
18 T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. W ARNING: Make sure main power is turned off. 2. Loose power line 2. Check line power connections connections to the fan.
LIMITED WARRANTY What The War ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson Electric Co. ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered.
Part No. F40BP73330000 Printed in China 12/06 Form No. BP7333 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant ¥ St. Louis, MO 63136 BP7333 CF750 MAYA ZEN 12/22/06 7:59 AM Pag.
Een belangrijk punt na aankoop van elk apparaat Emerson CF750ORB00 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Emerson CF750ORB00 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Emerson CF750ORB00 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Emerson CF750ORB00 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Emerson CF750ORB00 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Emerson CF750ORB00 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Emerson CF750ORB00 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Emerson CF750ORB00 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.