Part No. F40BP74320000 Form No. BP7432 U.L. Model No.: CF905 READ AND SA VE THESE INSTRUCTIONS Ceiling F an Owner's Manual CF905BS00 CF905CK00 CF905GES00 Model Number s PRIMA SNUGGER Net W eight: 18.
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally.
3 U.L. Model No.: CF905 EMERSON QUICK ST ART GUIDE The Quick Start Guide covers the installation instructions common for ceiling fan operations. If additional assistance with wiring, alternate hanging systems, or lighting options, proceed to the complete instructions of this Owner’s Manual.
4 U.L. Model No.: CF905 How to Put Y our Ceiling Fan T ogether (pages 9 & 10) 1. Remove the 10-24 x 3/8” pan head screw with lockwasher nearest the hook from the ceiling mounting plate and retain for later use. Loosen the remaining two 10-24 x 3/8” pan head screws several turns.
How to Put Y our Ceiling Fan T ogether (pages 10 & 1 1) EMERSON QUICK ST ART GUIDE NOTE: Electric connections should be in accordance with the National Electrical Codes and all Local Codes. Before starting, disconnect power to the circuit at the fuse box or circuit breaker panel.
Unpac king Instr uctions 1. Open carton containing fan. Remove top half of styrofoam unit. Remove parts and check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. a.
7 Electrical R equir ements Ho w to Hang Y our Ceiling F an If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
8 Ho w to W ir e Y our Ceiling F an FAN MOTOR ASSEMBL Y CEILING MOUNTING PLA TE HOOK RADIAL SLOT HOLE Figure 3 FAN MOTOR ASSEMBL Y SUPPL Y BLACK WIRE SUPPL Y WHITE WIRE SUPPL Y GREEN WIRE FAN MOTOR BLUE WIRE FAN MOTOR BLACK WIRE FAN MOTOR WHITE WIRE Figure 4 1.
9 U.L. Model No.: CF905 FAN MOTOR ASSEMBL Y KEY HOLE SLOT 10-24 x 3/8" PAN HEAD SCREW WITH LOCKWASHER (3) Figure 5 1. Remove the 10-24 x 3/8” pan head screw with lockwasher nearest the hook from the ceiling mounting plate and retain for later use.
10 U.L. Model No.: CF905 Ho w to Put Y our Ceiling F an T ogether (continued) CEILING TRIM RING FAN HOUSING COVER MOUNTING SCREW HEADS Figure 9 FAN BLADE 10-24 x 5/16" WASHER HEAD BLADE SCREW (3) BLADE FLANGE Figure 10 9.
11 U.L. Model No.: CF905 Ho w to Put Y our Ceiling F an T ogether (continued) SWITCH HOUSING ASSEMBL Y MOUNTING SCREWS (4) Figure 13 14. Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate.
W all Control Installation 12 U.L. Model No.: CF905 This control is designed to operate only one ceiling fan, and not an accessory light kit. This wall control is rated for 1.
13 U.L. Model No.: CF905 Ener gy Ef ficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan. Here are a few tips to ensure quality and product performance. Choosing the Appropriate Mounting Location.
14 U.L. Model No.: CF905 T r ouble Shooting WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan. TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1.
15 U.L. Model No.: CF905 R epair Par ts 3 8 13 15 2 1 10 4 9 5 12 6 7 14 4 0 3 2 1 11 Key Model Numbers No. Description CF905BS00 CF905CK00 CF905GES00 CF905ORB00 CF905VNB00 1 Ceiling Mounting Plate 76.
Part No. F40BP74320000 Printed in China 01/11 Form No. BP7432 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 U.
Een belangrijk punt na aankoop van elk apparaat Emerson CF905CK00 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Emerson CF905CK00 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Emerson CF905CK00 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Emerson CF905CK00 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Emerson CF905CK00 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Emerson CF905CK00 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Emerson CF905CK00 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Emerson CF905CK00 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.