Part No. F40BP72650000 Form No. BP7265 READ AND SA VE THESE INSTRUCTIONS Model No. CF945WB 00 CF945HTW 00 CF945AB 00 CF945PW 00 CHA TEAU ROY ALE Series Ceiling Fan Owner's Manual ® Net Weight: 33.
2 W ARNING ! WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference.
1. Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration. a. Fan motor assembly b. One switch housing c. Five fan blades d. One ceiling cover e. Five blade flanges f.
IMPORTANT This Owner’s Manual is divided into two sections. The first section, REMOTE CONTROL PROCEDURES, describes how to install the 9-volt alkaline battery (not included) in the remote control transmitter, and how to set the operating frequency of the transmitter and receiver.
Setting Operating Fr equency of T ransmitter and Receiver Your remote control transmitter and receiver have code switches which must be set on one of 16 possible code combinations. The four levers (numbered 1, 2, 3, and 4) on the switches are factory- set in the ON (up) position.
5. Reinstall the hanger ball (Figure 5) on the downrod as follows. Route the two 80” motor leads through the hanger ball. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball.
7 If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. 10. Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation).
8 17. The blade flanges have an interlocking feature that must be fully engaged before tightening the screws. Make sure all the flanges are properly engaged and then tighten the flange screws.
9 Installation of the Decorative Suppor t Rods Assembly NOTE: The following procedures are to be performed only if you have installed the 18” (or longer) downrod. 1. Loosen the setscrew in the collar of the rod support assembly using the 5/64” hex wrench (supplied) and slide the support assembly over the downrod (Figure 16).
10 Operation IMPORTANT Fan installation must be completed, including the installation of the fan blades, before testing of the remote control. Your remote control has full control of your fan and lights. NOTE: Prior to operation of the down light from the remote control, make sure the switch on the light is ON.
T r ouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan 2. Check line wire connections to fan in the in the ceiling cover.
Model No. Key N o. Description CF945WB00 CF945HTW00 CF945AB00 CF945PW00 Hanger Ball Assembly, 761655-20 761655-12 761655-3 761655-22 Consisting of: 1 Hanger Bracket — — — — 2 Hanger Ball — .
Een belangrijk punt na aankoop van elk apparaat Emerson CF945PW (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Emerson CF945PW heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Emerson CF945PW vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Emerson CF945PW leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Emerson CF945PW krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Emerson CF945PW bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Emerson CF945PW kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Emerson CF945PW . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.