Gebruiksaanwijzing /service van het product KF240PRZ00 van de fabrikant Emerson
Ga naar pagina of 20
Net Weight: 27.0 Lbs. Part No. F40BP73080000 Form No. BP7308 READ AND SA VE THESE INSTRUCTIONS KF240PRZ00 Parisian Bronze with Dar k Cher r y/Walnut Blades LORRAINE Ceiling Fan Owner's Manual Eme.
W ARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’s manual carefully and keep it for future reference.
3 This Manual Is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan Do not install or use fan if any part is damaged or missing.
4 p. One loose parts bag containing: 1. T wo 8-32 x 1-1/4” threaded studs 2. T wo knurled knobs 3. T wo lockwashers 4. Seven wire connectors 5. One clevis pin/hairpin clip assembly 6. Eleven 1/4-20 x 13mm oval head screws 7. Sixteen 10-24 x 8mm truss head screws 8.
5 Y our new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
4. Remove and retain one of the three pan head screw/lockwashers from the motor flange (Figure 2); loosen the other two pan head screws three or four turns. 5. Position the light fitter adapter on the motor flange so that the two screws mate with the two keyhole slots in the light fitter adapter (Figure 3).
8. Remove and retain the three outer screw/lockwashers from the light fitter adapter (Figure 4). 9. Position the light fitter assembly on the light fitter adapter . Line up the three holes on the light fitter with the threaded holes in the adapter and reinstall three screw/lockwashers (previously removed) (Figure 5).
8 12. Unscrew the two upper setscrews (Figure 8) until they clear the inside of the motor coupling. Then separate, untwist and unkink the three 80” motor leads. Route the motor lead wires through the downrod. Align the clevis pin holes in the downrod with the holes in the motor coupling.
9 16. Place the ceiling cover over the downrod. Then reinstall the hanger ball (Figure 10) on the downrod as follows. Route the three 80” motor leads through the hanger ball and slide the hanger ball over the downrod.
10 2. Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 13). Be sure the groove in the ball is lined up with the tab on the hanger bracket (Figure 12). Hanger bracket must seat firmly against outlet box.
1. Position the supply wires to the left side of the outlet box (Figure 14); position the fan wires to the right side. Partially insert the remote control receiver (flat side up) until one end rests on the hanger ball as shown in Figure 14. NOTE: Make all wiring connections using wire connectors (supplied).
12 7. Screw in three 40-watt (maximum) candelabra bulbs in the light fitter sockets (Figure 17). Carefully place the lower glass over the light fitter threaded nipple. Be sure the glass is firmly seated on the fitter , then secure in place using a rubber washer , metal washer , and 1/8-27 nut (washers and nut are supplied).
Installation of W all Control SINGLE-POLE INST ALLA TION (Figure 19) 1. Disconnect power at circuit breaker or remove fuse. 2. Remove faceplate and screws from existing wall control. Pull control out from the wall box. Determine the “hot” wire and the “load” wire and disconnect these wires from control.
3. Before installing wall control, place wall control in “OFF” mode by pushing “ON/OFF” switch to the “OFF” position. 4. Install a wall control in the wall box containing the “hot” wire first. Connect the black wire of the wall control to the “hot” wire.
9. Place the second wall control into the wall box. Screw in place and install decorator style faceplate (included). Leave switch in “OFF” mode until fan installation is completed.
16 Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock. ! W ARNING The use of any other control not specifically approved for this fan could result in fire, shock and personal injury .
17 T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. W ARNING: Make sure main power is turned off. 2. Loose power line 2. Check line power connections connections to the fan.
Repair Parts 1 17 18 22 29 30 20 9 8 21 12 11 10 15 14 13 26 27 19 23 28 24 25 31 HI MED LOW FAN OFF LIGHT ON OFF EMERSON 1 2 3 4 ON 2 3 5 4 16 6 7 Before discarding packaging material, be certain all parts have been removed.
Part Numbers Key Model No. N o . Description KF240PRZ00 * Hanger Pack, Consisting of: 761655-53 1 Hanger Bracket — 2 Hanger Ball — 3 Downrod (16”) — * Parts Bag, Containing: 763046 4 Wire Conn.
LIMITED WARRANTY What The War ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson Electric Co. ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered.
Een belangrijk punt na aankoop van elk apparaat Emerson KF240PRZ00 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Emerson KF240PRZ00 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Emerson KF240PRZ00 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Emerson KF240PRZ00 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Emerson KF240PRZ00 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Emerson KF240PRZ00 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Emerson KF240PRZ00 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Emerson KF240PRZ00 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.