Mobrey MSP900SH Series Level Transmitter Page 1 MSP900SH Installation, Operation & Maintenance Manual IP2040/IM, Rev. AA May 2007 Software version 2.
Page 2 MSP900SH Installation, Operation & Maintenance Manual IP2040/IM, Rev. AA May 2007 CONTENTS Page 1. Introduction 3 2. The MSP900SH ultrasonic level transmitter 3 2.1 Type numbering system 3 2.2 Safety data 4 2.3 Pressure Equipment Directive 4 2.
Page 3 MSP900SH Installation, Operation & Maintenance Manual IP2040/IM, Rev. AA May 2007 1.0 Introduction The MSP900 ultrasonic level transmitter is d esig ned to b e m ounted above a liquid and will measure the distance to the liquid surface.
Page 4 MSP900SH Installation, Operation & Maintenance Manual IP2040/IM, Rev. AA May 2007 2.2 Safety Data Type numbers MSP900SH-A/** MSP900SH-U/** Certificate numbers ATEX BAS 01ATEX1061X FM 302119.
Page 5 MSP900SH Installation, Operation & Maintenance Manual IP2040/IM, Rev. AA May 2007 3.0 Installation The MSP900SH may be mounted in a hazar dous ar ea provided it is suppli ed throu gh or from a suitably protected power supply (such as the Mobrey Measure ment MCU900 Series).
Page 6 MSP900SH Installation, Operation & Maintenance Manual IP2040/IM, Rev. AA May 2007 3.1.1 General considerations • The MSP900SH transmitter complies with the European Dir ective for Elect ro Magnetic Compatibilit y (EMC) Class B.
Page 7 MSP900SH Installation, Operation & Maintenance Manual IP2040/IM, Rev. AA May 2007 It is important to note that the bottom refe rence of the transmitter should be related to the centre of the invert of the prima ry device, NOT the distance to the channel bottom directly bel o w the transmitter.
Page 8 MSP900SH Installation, Operation & Maintenance Manual IP2040/IM, Rev. AA May 2007 • In many installations, the us e of a calibr ation device is mandatory.
Page 9 MSP900SH Installation, Operation & Maintenance Manual IP2040/IM, Rev. AA May 2007 3.4 Additional compone nts in the t wo wire loop 3.4.1 Safety barriers – installa tion of the transmitter.
Page 10 MSP900SH Installation, Operation & Maintenance Manual IP2040/IM, Rev. AA May 2007 3.6.1 Wiring When connecting the MSP900SH transmitter to an MSP90 Series co nt rol unit, different terminals are used in the cont rol un it. If connected, disconnect the existing MSP90 type transducer.
Page 11 MSP900SH Installation, Operation & Maintenance Manual IP2040/IM, Rev. AA May 2007 5.0 Commissioning / Programming 5.1. Current Output This section gives a very brief overvie w to allow checking of the installation. For full programming details, refer to the Operating Manual IP2040/OM.
Page 12 MSP900SH Installation, Operation & Maintenance Manual IP2040/IM, Rev. AA May 2007 6.0 Accessories 6.1 Submersion shield The MSP-SUB2 is a tubular shield which slip s over the black transmitter front housing. This is usually fitted in wet well installations where the liqui d level coul d ri se faster than the pumps can pump out.
Page 13 MSP900SH Installation, Operation & Maintenance Manual IP2040/IM, Rev. AA May 2007 Appendix I : MSP900SH programming para mete rs.
Page 14 MSP900SH Installation, Operation & Maintenance Manual IP2040/IM, Rev. AA May 2007 Appendix 2 - Use with Mobre y Measu r ement MSP90 Series controllers – exa mple Programming example when using the new MSP900SH transmi tter with an old style MS P90 Seri es controller.
Page 15 MSP900SH Installation, Operation & Maintenance Manual IP2040/IM, Rev. AA May 2007 Appendix 3 - Intrinsically safe control drawing.
Page 16 MSP900SH Installation, Operation & Maintenance Manual IP2040/IM, Rev. AA May 2007 The Emerson logo is a trade mark and serv ice mark of Emerson Ele ctric Co. Rosemount is a registe red tr ademark of Rosemoun t Inc. Mobrey is a registe red trademark of M obrey Ltd.
Een belangrijk punt na aankoop van elk apparaat Emerson Process Management MSP900SH (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Emerson Process Management MSP900SH heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Emerson Process Management MSP900SH vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Emerson Process Management MSP900SH leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Emerson Process Management MSP900SH krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Emerson Process Management MSP900SH bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Emerson Process Management MSP900SH kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Emerson Process Management MSP900SH . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.