EMI AMERICA SERIES MUL TI-ZONE LIMITED RANGE HEA T PUMP CONDENSING UNITS P/N# 240006458 Rev . 1.1 [04/07] Enviromaster International LLC 5780 Success Dr .
.
www .enviromaster .com 3 Multi-zone Heat Pump Condensing Units INST ALLA TION, OPERA TION AND MAINTENANCE MANUAL EM I AM ER ICA S ER IE S MU L T I- ZON E HE A T P UM P CO ND EN SIN G UN IT S P/N 240006458, Rev .
www .enviromaster .com 4 Multi-zone Heat Pump Condensing Units EM I AM ER ICA SE RI ES MUL TI- ZO NE H EA T PU MP CO NDE NS ING UN IT S CON TROLS AND COMP ONEN TS (F ACT ORY INST ALLED OR S UPPLI ED) .
www .enviromaster .com 5 Multi-zone Heat Pump Condensing Units S2HA INST ALLA TION INSTRUCTIONS 1. Loosen the screws on left and right sides of the front panel. (Do not remove these screws.) 2. Remove the screws on the front of the panel. 3. T o remove front panel: 4.
www .enviromaster .com 6 Multi-zone Heat Pump Condensing Units S2HA ELECTRICAL WIRING INST ALLA TION SECTION 3. Use only HACR type breakers or time delay fuses. Select the wire size accord - ing to the ampacity rating. 4. T o access electrical connections and wiring diagram: a) Remove the screws on the side panel adjacent to the back panel.
www .enviromaster .com 7 Multi-zone Heat Pump Condensing Units 8. Check wiring diagram for the re- quired number of low voltage wires to be run between indoor and out- door sections.
www .enviromaster .com 8 Multi-zone Heat Pump Condensing Units T2HA INST ALLA TION INSTRUCTIONS N OT E: F or S 2H A i ns ta ll at i on re fe r to t he S 2H A I ns ta l la t io n In st ru ct io n i n t hi s ma nu al . 1. Remove the screw on the back panel.
www .enviromaster .com 9 Multi-zone Heat Pump Condensing Units 5. With a screw- driver punch out and re- m o v e t h e knock-outs in the low & high V olt electrical connection box. Note: Power should be run to a weather proof disconnect box usually within 3 feet of the unit.
www .enviromaster .com 10 Multi-zone Heat Pump Condensing Units The system will support refrigerant runs to the inside unit of up to 100' equivalent feet with a 35' rise included.
www .enviromaster .com 1 1 Multi-zone Heat Pump Condensing Units 8. Evacuate line to 500 microns or less to ensure all moisture has been removed and there are no leaks.
www .enviromaster .com 12 Multi-zone Heat Pump Condensing Units 9. Once ce rt ai n o f a go od ev ac ua ti on an d l ea k fr e e j oi nt s, ba ck -s ea t t he va lv es ( co un te r- cl oc kw is e ) t o op en an d al lo w f ac to ry ch ar g e to fi ll li ne s an d i nd oo r u ni t.
www .enviromaster .com 13 Multi-zone Heat Pump Condensing Units S2HA & T2HA REFRIGERANT PIPING INST ALLA TION SECTION Th e us e of th e su pe rhe at me tho d i s hi gh ly re co mm en ded f or fie ld ch ar gi ng or ch ec ki ng th e ex is ti ng ref ri ge ran t c har ge in a sys te m.
www .enviromaster .com 14 Multi-zone Heat Pump Condensing Units MUL TI-ZONE HEA T PUMP FIELD CHARGING .
www .enviromaster .com 15 Multi-zone Heat Pump Condensing Units .
www .enviromaster .com 16 Multi-zone Heat Pump Condensing Units .
www .enviromaster .com 17 Multi-zone Heat Pump Condensing Units MUL TI-ZONE HEA T PUMP FIELD CHARGING .
www .enviromaster .com 18 Multi-zone Heat Pump Condensing Units ST ARTING THE UNIT • Before starting the unit in cool weather , powe r the syst em 24 hour s b efore at- tempting to start. • Do a final system check using the super - heat/subcooling method.
www .enviromaster .com 19 Multi-zone Heat Pump Condensing Units ST ART -UP AND TROUBLESHOO TING TEST PROCEDURE The T est Unit Performance Data sheet below is provided for use by a qualified ser vice pro fess iona l.
www .enviromaster .com 20 Multi-zone Heat Pump Condensing Units MUL TI-ZONE CONDENSER SEQUENCE OF OPERA TION EMI Amer ica Series mult i-zo ne he at p ump con dense rs are desig ned to opera te with EMI Amer ica Ser ies ind oor air han dler s.
www .enviromaster .com 21 Multi-zone Heat Pump Condensing Units MUL TI-ZONE CONDENSER SEQUENCE OF OPERA TION When the outdoor temperature falls below 35°F , compressor operation will cease. At that point the unit will switch on the indoor units electric heater to assume the heating demand, (second stage of heat) .
www .enviromaster .com 22 Multi-zone Heat Pump Condensing Units S2HA DIMENSIONS AND SPECIFICA TIONS NOTE: All EMI products are subject to ongoing development programs so design and specifications may change without notice. S2HA ELECTRICAL SPECIFICA TIONS MODEL (1) VOL TS/HZ/PHASE F AN COMPRESSOR 1 COMPRESSOR 2 TOT AL AMPS MIN.
www .enviromaster .com 23 Multi-zone Heat Pump Condensing Units S2HA SYSTEM PERFORMANCE S2HA / WLHA SYSTEM PERFORMANCE MODEL COOLING HEA TING S2HA (Outdoor) Indoor Units Btuh SEER SHR EER Btuh C.O.P . 9900 WLHA09 + WLHA09 18,600 13.0 .80 12.2 16,000 3.
www .enviromaster .com 24 Multi-zone Heat Pump Condensing Units T2HA DIMENSIONS AND SPECIFICA TIONS NOTE: All EMI products are subject to ongoing development programs so design and specifications may change without notice. SOUND & WEIGHT DA T A Model Sound Weight dBA Lbs.
WLHA / T2HA SYSTEM PERFORMANCE DAT A Model Cooling Heating T2HA Outdoor Condenser Indoor Air Handler Btuh SEER SHR EER Btuh COP 8800 WLHA24 + WLHA24 36000 13 0.72 12.4 29000 3.3 8400 WLHA24 + WLHA24 42000 13 0.68 12.2 34800 3.2 4400 WLHA24 + WLHA24 48000 13 0.
Een belangrijk punt na aankoop van elk apparaat EMI S2HA (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen EMI S2HA heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens EMI S2HA vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding EMI S2HA leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over EMI S2HA krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van EMI S2HA bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de EMI S2HA kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met EMI S2HA . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.