16943-5-0806 Page 1 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL UNVENTED ROOM HEA TER MODELS BF-10-2 BF-20-2 BF-30-2 EFFECTIVE DA TE AUGUST 2006 W ARNING: If not installed, operated and ma in .
Page 2 16943-5-0806 SECTION P AGE Important Safety Information ......................................................................................................................3 Safety Information for Users of LP Gas .............................
16943-5-0806 Page 3 THIS IS A HEA TING APPLIANCE DO NOT OPERA TE THIS APPLIANCE WITHOUT FRONT P ANEL INST ALLED. • An unvented r oom heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom.
Page 4 16943-5-0806 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can af fect your sensitivity or ability to detect that odor .
16943-5-0806 Page 5 Qualified Installing Agency Installation and replacement of gas piping, gas utilization equip - ment or accessories and repair and servicing of equipment shall be performed only by a qualified agency .
Page 6 16943-5-0806 W ater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 Btu (.3KW's) of gas input per hour . Unvented room heaters must be used as supplemental heat (a room) rather than a primary heat source (an entire house).
16943-5-0806 Page 7 The gas line can be routed either through the floor or wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing.
Page 8 16943-5-0806 SRS-18* and SRS-30 Floor Stand Installation 1. Align clearance holes on floor stand with screw holes on bottom of heater , as shown in Figure 5. 2. Attach floor stand to heater with (4) screws provided with floor stand. 3. Connect the gas line.
16943-5-0806 Page 9 On Sheet Rock W all 1. After locating mounting holes, drill (4) 5/16" (8mm) diameter holes into the wall. 2. Insert (4) plastic expansion anchors provided into the holes. 3. T ighten (4) #10 x 1" (25mm) screws provided into the plastic expansion anchors.
Page 10 16943-5-0806 T O TURN OFF GAS T O APPLIANCE 1. STOP! Read the safety information above. 2. Set thermostat (gas control knob) to lowest setting. 3. T urn off all electric power to the appliance (if applicable). 4. Push in gas control knob slightly and turn clockwise to "OFF".
16943-5-0806 Page 1 1 Piezo Pilot Ignitor Instructions Depressing the ignitor button completely causes a spark to occur at the pilot. T o light the pilot, it is important that the electrode be 1/8" (3mm) from the pilot. The spark must occur at the point the pilot flame hits the thermocouple.
Page 12 16943-5-0806 The correct flame will be blue and will extend beyond the thermo- couple. The flame will surround the thermocouple just below the tip.
16943-5-0806 Page 13 Glass Removal, Cleaning and Glass Replacement 1. Remove chrome grill from reflector . 2. Slide glass upward to remove glass from chrome grill. 3. Clean glass with a non-abrasive household glass cleaner and warm water . Gas fireplace glass cleaner can also be used.
Page 14 16943-5-0806 1. Spark electrode does not pr oduce spark. a. Spark electrode broken - replace. b. Ignitor wire ma y not be attache d to spa rk elect rode - attach. c. Ignitor wire damaged - replace. d. Piezo ignitor defective - replace. 2. Spark electrode pr oduces spark but pilot does not light.
16943-5-0806 Page 15 INDEX P ART NO. NO. DESCRIPTION INDEX P ART NO. NO. DESCRIPTION 01 13347 C A S I N G S I D E AS S E M B L Y - L E F T (B F - 1 0 ) 01 13348 CASING SIDE ASSEMBL Y - LEFT (B F - 2 0.
Page 16 16943-5-0806 P AR TS VIEW.
16943-5-0806 Page 17 INST ALLING OPTIONAL BLOWER SRB-18T OR SRB-30T If heater is installed onto the wall, in order to install the optional blower, the heater must be removed from the wall. If heater is installed on SRS-18 or SRS-30 optional floor stand there is adequate access area available to install the optional blower .
Page 18 16943-5-0806 . . . . P AR TS LIST Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or , in the absence of local codes, with the National Electri- cal Code, ANSI/NFP A 70, if an external electrical source is utilized.
16943-5-0806 Page 19 SER VICE NOTES.
Page 20 16943-5-0806 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.
Een belangrijk punt na aankoop van elk apparaat Empire Comfort Systems BF-10-2 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Empire Comfort Systems BF-10-2 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Empire Comfort Systems BF-10-2 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Empire Comfort Systems BF-10-2 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Empire Comfort Systems BF-10-2 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Empire Comfort Systems BF-10-2 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Empire Comfort Systems BF-10-2 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Empire Comfort Systems BF-10-2 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.