Page 1 16938-3-0806 INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL CAST IRON UNVENTED ROOM HEA TER MODEL CIVF-25-21 EFFECTIVE DA TE AUGUST 2006 W A TER V APOR: A BY -PRODUCT OF UNVENT - ED ROOM HEA TERS W ater vapor is a by-product of gas combustion.
Page 2 16938-3-0806 SECTION P AGE Important Safety Information ................................................................................................. 3 Safety Information for Users of LP Gas .................................................
Page 3 16938-3-0806 IMPOR T ANT SAFETY INFORMA TION • An unve nted room heater h aving an inp ut rat ing of mor e than 6,000 Btu per hour shall not be installed in a bathroom. • An unvented room heater having an input rating of more than 10,000 Btu per hour shall not be installed in a bedroom or bathr oom.
Page 4 16938-3-0806 SOME POINTS T O REMEMBER NO ODOR DETECTED - ODOR F ADE LP-GAS W ARNING ODOR If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas.
Page 5 16938-3-0806 Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of an unvented room heater . This appliance may be installed in an aftermarket* permanently located, manufactured (mobile) home, where not prohibited by state or local codes.
Page 6 16938-3-0806 W A TER V APOR: A BY -PRODUCT OF UNVENTED ROOM HEA TERS PROVISIONS FOR ADEQUA TE COMBUSTION & VENTILA TION AIR W ater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.
Page 7 16938-3-0806 Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Inside Diameter T ubing, T ype L Outside Diameter Nat. L.P . Nat. L.P . 0-10 feet 0-3 meters 1/2” 12.7mm 3/8” 9.5mm 1/2” 12.7mm 3/8” 9.5mm 10-40 feet 4-12 meters 1/2” 12.
Page 8 16938-3-0806 CLEARANCES Clearances (Figures 2, 3 and 4) When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.
Page 9 16938-3-0806 APPLIANCE HARDW ARE P ACKAGE Figure 5 Appliance Hardware Package Parts List Part Description Part Number Quantity Supplied 1/4-20 x 1" Phillips Head Bolt R-3188 4 1/4-20 x 3/8" Phillips Head Bolt R-3646 16 1/4-20 x 1/2" Leveling Bolt R-3747 4 No.
Page 10 16938-3-0806 ASSEMBL Y OF STOVE CASTING Figure 6 Assembly of Stove Casting (Figures 6, 7, 8, 9, 10, 1 1 and 12) Attention: Included in the hardware package are (8) 1/4" inside diameter washers. A 1/4" washer may be used with a 1/4-20 x 3/8" bolt when assembling the stove casting parts.
Page 1 1 16938-3-0806 Figure 8 7. Refer to Figure 7, the rear cover has (4) keyholes for attachment to the casting sides. Stand the casting sides on the floor with the (2) bolts attached half-way into the edges of the rear cover positioned at the rear .
Page 12 16938-3-0806 ASSEMBL Y OF STOVE CASTING (continued) Figure 10 Figure 1 1 1 1. Refer to Figure 9, attach casting front to casting by using the (4) retaining tabs on the casting front. The (2) top, retaining tabs on the casting front will be placed behind the (2) top, locator tabs on the front of the casting sides.
Page 13 16938-3-0806 OPTIONAL STONE INLA Y INST ALLA TION WIRE CHANNEL INST ALLA TION The ON/OFF/REMOTE switch with harness is factory installed into the switch box. After the firebox is installed into the casting the wire channel can be installed. 1.
Page 14 16938-3-0806 Before operating this heater , please review the safety warnings pages at the beginning of this manual and those precautions and warnings listed below . 1. Know what type of ignition system this model has (standing pilot) and follow the applicable SAFETY and LIGHTING instructions.
Page 15 16938-3-0806 LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPER TY DAMAGE, PERSONAL INJUR Y OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted by hand.
Page 16 16938-3-0806 PILOT FLAME CHARACTERISTICS Figure 15 shows a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple and ther- mopile. The flame will surround the thermocouple and thermopile just below the tip.
Page 17 16938-3-0806 MAIN BURNER FLAME CHARACTERISTICS Figure 18 shows a correct main burner flame pattern. Figure 19 shows an incorrect main burner flame pattern. If main burner flame pattern is incorrect, as shown in Figure 19 • See Troubleshooting, pages 20-21.
Page 18 16938-3-0806 CIVF-25 ON/OFF/REMOTE Switch CIVF-25 is equipped with an ON/OFF/ REMOTE switch which is located on the wire channel. A wire harness is attached to the ON/OFF/ REMOTE switch. The red, black an d green (wi res) fema le push-ons attach to the ON/OFF/REMOTE switch.
Page 19 16938-3-0806 Wiring Diagram (Figur e 21) Figure 21 MAINTENANCE IMPOR T ANT : T urn off gas before servicing appliance. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season.
Page 20 16938-3-0806 SYMPTOMS - POSSIBLE CAUSES AND CORRECTIONS IMPOR T ANT : Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover , cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes.
Page 21 16938-3-0806 9. Slight smoke or odor during initial operation. a. Residues from manufacturing processes and logs curing - Problem will stop after a few hours of operation.
Page 22 16938-3-0806 Index Part No. Number Description Index Part No. Number Description 1 *CI-006 WINDOW RET AINING T AB 2 R-3948 WINDOW (BLACK P AINT) 2 R-3688 WINDOW (BLACK ENAMEL) 2 R-3696 WINDOW .
Page 23 16938-3-0806 P AR TS VIEW FOR ST OVE CASTING Models: CIFB-1, CIPB-1, CIPG-1, CIPS-1, CIPN-1, CIPR-1.
Page 24 16938-3-0806 P AR TS VIEW FOR CIVF-25-21.
Page 25 16938-3-0806 Installing Optional CIB-2 Blower 1. Loosen, but do not remove, (4) hex-head screws located on the exterior , bottom of the appliance. 2. Position the blower assembly at the rear of the appliance. The blower assembly has (4) keyholes for attachment to the exterior , bottom of the appliance.
Page 26 16938-3-0806 Cleaning The blower wheel will collect lint and could require cleaning once a year . If the air output decreases or the noise level increases, it indicates a dirty wheel. Blower Motor The blower motor does not have oiling holes. Do not attempt to oil blower motor .
Page 27 16938-3-0806 SER VICE NOTES.
Page 28 16938-3-0806 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.
Een belangrijk punt na aankoop van elk apparaat Empire Comfort Systems CIVF-25-21 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Empire Comfort Systems CIVF-25-21 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Empire Comfort Systems CIVF-25-21 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Empire Comfort Systems CIVF-25-21 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Empire Comfort Systems CIVF-25-21 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Empire Comfort Systems CIVF-25-21 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Empire Comfort Systems CIVF-25-21 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Empire Comfort Systems CIVF-25-21 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.