Gebruiksaanwijzing /service van het product EF3 van de fabrikant Enviro
Ga naar pagina of 38
PLEA SE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER.
T able of Contents 2 Introduction...................................................................................................................................3 P ellet Quality .....................................................................
3 Introduction P ELLET Q UALITY : Pellet quality is important, please read the following: Your enviro pellet stove has been designed to burn wood pellets only.
4 Introduction I MPORTANT S AFETY D ATA : Please read this entire Owner’s Manual before installing or operating your ENVIRO Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death.
5 Introduction ASHES: Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be on a non-combustible floor on the ground, well away from all combustible materials pending final disposal.
6 Oper a ting Instructions A UTOMATIC S AFETY F EATURES : Y our pellet Stove has the following saf ety featur es: A. The stove will shut off when the fire goes out and the exhaust temperature drops below 120°F (49°C). B. The stove has a high temper ature safety switch.
7 Oper a ting Instructions O PERATING Y OUR P ELLET S TOVE : Figure 3: Dial-A-Fire control panel. 1. Check and fill hopper with pellets. 2. Make sure unit is plugged into a working outlet. 3. Switch the power “ON” by pushing the start -up switch once only .
8 R outine Cleaning and Maintenance NOTE: Do not use abrasiv e cleaners to clean the surface or any part of the sto ve. The following should be inspected periodical ly to ensure that the appliance is .
9 ASH PAN (2-3 days) Monitor the ash level every week. Remember that different pellet fuels will have different ash contents. Ash content is a good indication of fuel efficiency and quality . Refer to “Warnings and Recommendations” for disposal of ashes.
10 Installation of firebox backing: • Install the side panels in place. Insert center panel, hold the panels in place • Install the top rod by sliding it into one side panel then across into the other panel. Screw rod in place. • Re-install steel brick liner and screw in place.
11 Inst alla tion D ECIDING W HERE TO L OCATE YOUR P ELLET A PPLIANCE : 1. Check clearances to combustibles. 2. Do not obtain combustion air from an attic, garage or any unventilated space. Combustion air may be obtained from a v entilated cra wlspace.
Inst alla tion D IMENSIONS - F REESTANDING : .
13 Inst alla tion C LEARANCES TO C OMBUSTIBLES - F REESTANDING : When installing this unit on a combustible floor (for example linoleum, hardwood flooring) a non- combustible hearth pad must be under the unit.
14 Inst alla tion C LEARANCES TO C OMBUSTIBLES - B UILT -I N H EATER : Ref er to Figures 11 and 12. Side wall to unit - 8 inches (20.3 cm) Mantel projection - 10 inches (25.4 cm) Mantel to top of unit - 8 inches (20.3 cm) T op facing to unit - 8 inches (20.
15 become hot enough to cause burns if touched by children. Non-combustible shielding or guards ma y be required. 3. T ermination must exhaust above the inlet elevation.
Outside fresh air is mandatory when installing this unit in airtight homes and mobile homes. When connecting to an outside fresh air source, do not use plastic or combustible pipe. A 1” minimum (42 mm) ID (inside diameter) steel, aluminum or copper pipe should be used.
17 Figure 21: Corner Installation. Inst alla tion M OBILE H OME I NSTALLATION - F REESTANDING : 1" (2.5cm) 1" (2.5cm) 6" (15 cm) Floor Protection Fresh Air Intake W all thimble manufactured by pellet vent manufacturer .
Inst alla tion H ORIZONTAL E XHAUST T HROUGH W ALL I NSTALLATION - F REESTANDING : Vent installation: install vent at clearances specified by the vent manufacturer. A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces, or a floor , or ceiling.
19 Inst alla tion 10. The pipe must extend at least 12” (30 cm) awa y from the building. If necessary , bring another length of pipe (PL type) to the outside of the home to connect to the first section. Do not forget to place high temperatur e silicone around the pipe that passes through the thimble.
Inst alla tion I NSIDE V ERTICAL I NSTALLATIONS - F REESTANDING : 1. Choose a sto ve location that is ideal. See the section “ D ECIDING W HERE TO L OCATE Y OUR P ELLET A PPLIANCE . ” Non-combustible floor protection. Existing floor (combustible) 6" (15 cm) 3" (7.
21 Inst alla tion Non-combustible floor protection. Existing floor (combustible) 6" (15cm) Rain cap Flashing 24" (61cm) 1" (2.5cm) T ee with cleanout Fresh air intake 3" (7.5cm) Clearance Support bracket T ype "L" vent Figure 27: Outside V ertical Installation.
Inst alla tion .
23 .
Non-combustible floor protection. Existing floor (combustible) 6" (15 cm) 3" (7.5 cm) Pedestal W all thimble Fresh air intake Rodent mesh cap 45° elbow 12" (30.
Inst alla tion 25 Figure 34: Corner brackets for trim. Figure 35: T wo pieces of corner bracket. 4. Plug the wiring harness into the contr ol panel (see Figure 33). 5. Loosen the front hopper lid screws and center the top surround panel under the hopper lid.
Inst alla tion S LIDER /D AMPER I NSTALLATION : This is used to regulate the airflow through the pellet stov e. 1. Remov e the slider rod (short rod with knob and nuts) from their package and open the left side panel. 2. R emove the knob and outer nut from the knob.
27 T roubleshooting DO NOT: ● Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly . Only qualified technicians should deal with possible internal electrical f ailures. ● Remove an y screws in the firebox without first lubricating them with penetr ating oil.
T roubleshooting ● Check V acuum levels in the exhaust channel by bypassing the V acuum Switch, then remove the V acuum hose from V acuum Switch. Check exhaust vacuum readings by placing the open end of the V acuum Hose on a Magnehelic Gauge (readings must be above 0.
29 T roubleshooting 6. The auger motor will not function normally. ● If the Auger gear box does not turn but the motor’s armature does try to spin then the auger is jammed.
8. The 200°F (93°C) high limit temperature sensor has tripped. ● Reset the sensor and determine the cause - was it convection blower or 160°F (71°C) temperature sensor failure? Bypass the 160°F (71°C) sensor . Does the convection blower come on high? If no, replace the blower .
31 W iring Diagr am T IMER C ONTROL : Yellow Yellow Purple Purple Orange Power Cord Brown Brown Red Ignitor 120 o F (49 o C) Ignitor Temperature Sensor 160 o F (71 o C) Convection Temperature Sensor C.
P ar ts List Reference Number Description Part Number Freestanding Fan Controller Knob EC-040 Power Cord - 1 15V EC-042 1 Auger Motor - 1 15V EF-001 2 Convection Blower - 1 15V EF-002 Convection Blowe.
33 Reference Number Description Part Number Firebox Liner T op Plate EF-066 Dial-a-Fire Knob EF-067 ” ID Auger Collar with Set Screw EF-069 Knob 1 Inch Round EF-070 Wiring Harness [T imer Control.
P ar ts List Reference Number Description Part Number 43 Control Panel T ouch Latch 50-323 44 Combustion Blower Exhaust T ube 50-327 45 Stainless Steel Burn Pot Liner - Domestic 50-474 45 Stainless St.
35 P ar ts Diagr am - Components EF3 - Components (115V) September 200.
P ar ts Diagr am - Steel .
37 W arr anty Sherwood Industries Ltd. gives a five year limited warrant y on all steel manufactured parts. A one-y ear warr anty is pr ovided on all electrical components.
38 The following information must be recorded by the installer for w arrant y purposes and future r eference. NAME OF OWNER: _________________________________________ ADDRESS: ________________________.
Een belangrijk punt na aankoop van elk apparaat Enviro EF3 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Enviro EF3 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Enviro EF3 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Enviro EF3 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Enviro EF3 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Enviro EF3 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Enviro EF3 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Enviro EF3 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.