Gebruiksaanwijzing /service van het product EG 40 B van de fabrikant Enviro
Ga naar pagina of 20
SHERWOOD INDUSTRIES IS AN ENVI RONMENTALLY RESPO NSIBLE COMPANY THIS MANUAL IS PRINTED ON RECYCLED PAPER EG 40 B Vented By SHERWOOD INDUSTRIES LTD. OWNERS MANUAL WHAT TO DO IF YOU SMELL GAS • Open windows • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
SAFETY PRECAUTIONS FOR SAFE INSTALLATION AND OPERATION OF YOUR "ENVIROGAS" STOVE, PLEASE, CAREFULLY READ THE FOLLOWING INFORMATION: GENERAL • Installation and repair should be do ne by a qualified service person. The appliance should be inspected before u se and at once least annually by a qualified service person.
3 TABLE OF CONTENTS Safety Precautions 2 Code Approvals 3 Deciding where to locate y our stove 4 Venting 6 Installation of Log Sets and Embers 8 Operating Instructions 9 Maintenance and Technica l 10 .
DECIDING WHERE TO LOCATE YOUR STOVE DIMENSIONS: FIG. 1 Front Width: 25"/ 63 cm Rear Width: 25"/ 63 cm Height: 29"/ 74 cm* Depth 21"/ 53 cm ( *not including vent coupling ) Shipping Weight: 256 lbs/116 kg CLEARANCES: A. Side wall to stove 12"/ 30cm B.
VENT TERMINAL CLEARANCES A= Clearance above grade, verandah, porch, deck, or [balcony (*12 inches (30cm ) minimum] B= Clearance to window or door that ma y be opened [*12 inches (30cm) minimu m] C= Cl.
VENTING This model must have a vent opening in the r ear of the unit. C onfirm this and als o check that the label on the right side pa nel door states "Vented Room Heater". WARNING: THIS APPLIANCE HAS BEEN DESIGNED TO OPERATE BY DRAWING COMBUSTION AIR AND DILUTION AI R FROM THE ROOM.
A. USING AN EXISTING CHIMNEY • Measure the height of the chimney beforehand and purchase the appropriate kit. Never attempt to over stretch a flexible liner to accommodate the height of the chimney. • Any flue damper must be removed or locked perman ently in the open position.
INSTALLATION OF LOG SET and EMBERS INSTALLING THE GLOWING EMBE RS A bag of ceramic fiber embers is provide d for use on the front burner ember tray. CAUTION: Use only the type of ember material supp lied wi th this appliance. Due to the irregular size of the ember material there may be more than requi red.
OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATIN G WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCT IONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE , PERSONAL INJURY OR LOSS OF LIFE. A) This applianc e is equipped with a pilot, which must be lit by hand by following these instructions exactly.
MAINTENANCE AND TECHNICAL Annually check to ensure that your Vent system is clear. Periodically check the pilot and burner. Che ck to see that all the burner port s are clean and clear. Check the pilot head for blockag e. Check to ensure the pilot flame is blue with small yellow tips.
TROUBLE SHOOTING Problem Possible Cause Solution Spark will not light the pilot after repeated pressing of sp ark igniter Defective piezo igniter Check connection s to igniter -If igniter connections .
GAS LINE CONNECTION ORIFICE SIZES, PRESSURE AND BTU’S NATURAL GAS PROPANE GAS FRONT BURNER #48 (1.93mm) #55 (1.32mm) REAR BURNER #41 (2.49 mm) #54 (1.40 mm) Manifold pressure. 3.8” wc (.95 kPa) 11” wc (2.74 kPa) Min. Manifold pressure. 1.1” wc (.
ELECTRICAL The ENVIROGAS EG 40.FS.BV. will operate with no external po wer supply. These models have a Milli volt gas control which uses the pilot flame to generate enoug h electricity to operate the main burner.
PARTS AND ACCESSORIES Service Parts available from your local Envirogas Dealer Burner Control Assembly Natural Gas Pilot Assembly Propane Pilot Assembly Door Bolt Relief Door Gasket Regulating Valve P.
• There is a separate air shutter for each burner. • Remove one screw from the cover pl ate located below the ash shelf. Loosen the other scre w (do not remove) swing the cover plate out of the way and tighten screw do wn to hold it in place. • With along screwdriver rotate spring clips to open or close the shutter to the desired setting.
16 WARRANTY Sherwood Industries Ltd. offers a *Lifetime Wa rranty on this gas produc t. The lifetime warranty covers the appliance for a period of seven years fro m the date of installation.
17 PARTS LIST EC-001 120 ° F CERAMIC TEMP SENSOR EG40-081 UPPER GOLD BARS (SET of 2) EC-003 300 ° F CERAMIC SPILL SWITCH EG40-084 FS LOWER GOLD BAR EC-006 S.
18 EG 40 DOOR AND BURNER ASSEMBLIES EXPLODED Page 1 of 2 JULY 2001 GLASS EXTRUSIONS DOOR LATCH STRIP HINGE SET OF 2 EG40-302 PAINTED DOOR ASSEMBLY WITH GLASS (A + B) EG40-073 GOLD DOOR ASSEMBLY WITH G.
19 FS UPPER BAR SET EG40-081 EG 40 FREESTANDING BODY (chassis) EXPLODED. Page 2 of 2 JULY 2001 EG 40 EMBLEM FS PEDESTAL DOOR EG40-135 FS ASH SILL EG40-213 FS LOWER BAR EG40-084 CONVECTION AIR DEFLECTO.
INSTALLATION DATA SHEET The following information must be recorded by the in staller for wa rranty purposes and future reference. Model: EG 40 20 Name of Dealer: _______________ ____________ _________.
Een belangrijk punt na aankoop van elk apparaat Enviro EG 40 B (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Enviro EG 40 B heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Enviro EG 40 B vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Enviro EG 40 B leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Enviro EG 40 B krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Enviro EG 40 B bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Enviro EG 40 B kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Enviro EG 40 B . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.