BY: SHERWOOD INDUSTRIES LTD O WNER ’S MANU AL EG28-120 E G 2 8 D V SHERWOOD INDUSTRIES IS AN ENVIRONMENT ALL Y RESPONSIBLE COMP ANY . THIS MANUAL IS PRINTED ON RECYCLED P APER.
FOR SAFE INST ALLA TION AND OPERA TION OF Y OUR “ENVIRO” HEA TER, PLEASE CAREFULL Y READ THE FOLLO WING INFORMA TION: • All ENVIRO gas-red appliances must be installed in accor dance with their instructions. Carefully read all the instructions in this manual rst.
T able of Contents 3 Safety Precautions...............................................................................2 T able of Contents.................................................................................3 Codes And Approv als..........
DIRECT VENT: This type is identied by the sufx DV . This appliance draws all of its air for combustion from outside the dwelling, through a specially designed v ent pipe system. This appliance has been tested and approved for installations from 0 feet to 4500 feet (1372 m) above sea level.
5 Specific a tions D IMENSIONS : 22" (559 mm) 19" (483 mm) 1 1" (279 mm) 4" (102 mm) 27 1 / 2 " (699 mm) Shipping Weight 210 lbs (95 kg) Figure 1: EG28 Exterior Dimensions. R ATING L ABEL L OCATION : The rating label is f ound inside the right cabinet side panel.
6 Oper a ting Instructions FOR YOUR SAFETY READ COMPLETELY BEFORE OPERATING. L IGHTING I NSTRUCTIONS : Figure 2: Lighting Instructions. Repoussez le bouton et tenez. Après la veilleuse a été allumée tenez le bouton pour 30 secondes. Degagez le bouton; si la veilleuse a eteint, repetez les etapes 4 et 5.
Thermopile Thermocouple Figure 4: Gas Valve. Figure 3: Pilot Burning. tips, are not getting enough air . Open the venturi until the ames clean up. If the venturi is opened, or closed all the way , and the correct ames cannot be attained, turn off the gas and contact the dealer .
Maintenance and Ser vice P eriodically check to ensure that your direct v ent system is clean. P eriodically check the pilot and burner . Check to see that all the burner ports are clean and clear . Check the pilot head for blockage. Check to ensure the pilot ame is blue with no or v ery small yellow tips.
9 Maintenance and Ser vice C LEANING P LATED S URFACES : It is important to note that ngerprints and other marks can lea ve a permanent stain on plated nishes. T o avoid this, give the face a quick wipe with denatured alcohol on a soft cloth BEFORE lighting the replace.
Maintenance And Ser vice F UEL C ONVERSION : Figure 9: Removing valve cap. 5. Conv ert the burner orice(s): a) R emove the main burner orice with a inch deep sock et. b) Put a bead of pipe-thread sealant or appro ved T eon tape on the orice threads before installing into the br ass elbow .
11 Maintenance And Ser vice b) Insert a 5 / 32 ” or 4 mm Allen wrench into the hexagonal key -wa y of the screw (see Figure 10), rotate it counter-clockwise until it is free and extract it. c) Check that the screw is clean and if necessary remove dirt.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. P REPARATION F OR I NSTALLATION : • Remov e the packaging from the appliance, and check to make sure there is no damage.
Vertical Termination Storm Collar Flashing Round Support Box/Wall Thimble Ceiling Firestop Pipelength Pipelength Cathedral Ceiling Support Box Pipelength Round Support Box/Wall Thimble Pipelength Hori.
Outside or Inside W all Outside W all Holes for screws to hold down the unit. 14 M OBILE H OME I NSTALLATION : • When the unit is installed in a Mobile Home it must be grounded to the steel chassis or connected to a grounding rod.
A A D E L B C F B B B J M K G H I Openable Fixed Closed Openable Fixed Closed Termination Cap Air Supply Inlet Gas Meter G G Restriction Zone (Termination not allowed) N O 1 In accordance with the current CSA B149, Natur al Gas and Propane Installation Code.
Figure 19: Wire Spacers. Figure 20: Wire Spacer in Place. the structure. 5. Project a level line from the center point of the elbow . Using this center point, scribe a 10” (25.4 cm) hole or square on the wall. Cut the hole out on both the interior and exterior wall surface.
17 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y Figure 21: Assembly of Venting Kit. W all framing Horizontal wall termination W all thimble fire stop Inside finished collar Decorative brass rings Exhaust 4" flex pipe Combustion air 6 5 / 8 " outer pipe Flue pipe adaptor 11.
Initial Inst alla tion QUALIFIED INST ALLERS ONL Y 18 16. Slide the 90° elbow over the ex pipe. Do not slip the outer sections of pipe together, you will require some movement in these pipe section in order to secure the ex pipe to the ue outlet on the appliance.
19 Table 4: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS). Direct Vent GS Direct-Temp Secure Vent Ameri Vent Direct Description 908 4DT -6 SV4L6 6” pipe length 4D7 7” .
T op of EG28 10 ft (3.0 m) 10 ft (3.0 m) 15 ft (4.6 m) 15 ft (4.6 m) 5 ft (1.5 m) 5 ft (1.5 m) 20 ft (6.1 m) 25 ft (7.6 m) 30 ft (9.1 m) 33 ft (10.1 m) Figure 23: Vent restrictor ring. Figure 22. Possible Vent Congurations; Vertical and Horizontal Terminations.
21 H ORIZONTAL I NSTALLATION : 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance.
wall thimble will conceal it (see left image in Figure 26). 7. Slide the decorativ e wall thimble up to the wall surface and attach with the screws provided.
23 V ERTICAL I NSTALLATION : 1. Check the instructions for required clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces. Do not pack air spaces with insulation.
support straps to the roof . Seal the nails holes heads with non-hardening mastic. T rim the excess length of the support straps that extend out bey ond the edge of the ashing. 7. Slip the ashing over the pipe section pr otruding through the roof .
25 Nails Ceiling firestop Ceiling Second floor Use clearances to as defined by appliance and vent pipe manufacturers. • For multi story installations. A ceiling restop is required at the second oor , and any subsequent oors (see Figure 33).
V ENTING INTO A C LASS ‘A’ C HIMNEY : This model is also certied and tested to vent into CL ASS ‘ A ’ wood stov e chimneys. Place the freestanding direct v ent appliance in the desired location. Use a conversion kit from Simpson Duravent (931, 932, or 933), or Security Chimney (SV4CCK1, SV4CCK2, or SV4CCK1).
27 Initial Inst alla tion QUALIFIED INST ALLERS ONL Y E LECTRICAL R EQUIREMENTS : The ENVIRO EG28 will operate without electrical power . This model has a millivolt gas control, which uses the pilot ame to generate enough electricity to operate the main burners.
Initial Inst alla tion G AS L INE C ONNECTION AND T ESTING : WARNING: Only persons licensed to work with gas piping ma y make the necessary gas connections to this appliance. GAS LINE CONNECTION • This stov e is equipped with a certied exible pipe located on the right side of the unit terminating in a ” male NPT tting.
29 Second ar y Inst alla tion I NSTALLATION OF L OG S ET AND E MBERS : The placement of the logs is not arbitrary . If they are positioned incorrectly , the ames can be “pinched” and will not burn correctly . The burner come with ve (5) locator pins and two (2) resing areas, which make alignment easier .
Second ar y Inst alla tion CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE GLASS DOOR REMOVED. 3. Place the log set into the rebox. Locate each log by seating it down onto the burner tray support pins. F ollow Figures 11 to 16 proper log placement. 4.
31 T rouble Shooting Problem Possible Cause Solution The main burner does not ignite when called for . The gas valv e may not be on. • Check that the gas control knob is in the “ON” position. Thermostat is not calling for heat. • Adjust the thermostat several degr ees above ambient temperature.
P ar ts List Reference Number Part Description Part Number 1 120°F (49°C) Ceramic T emperature Sensor EC-001 2 Thermocouple EC-009 2 Spark Electrode with Cable EC-011 2 Thermopile EC-012 2 Pilot NG .
33 P ar ts List Reference Number Part Description Part Number 14 Pedestal Door EG28-109 15 Burner T ray T op EG28-116A DV Owner’s Manual EG28-120 16 Cabinet Side Panel EG28-123 Firebox Bafe EG28-.
P ar ts Diagr am - Chas sis EG 28 Body (Chassis) DV April 2006 34.
35 P ar ts Diagr am - Gas T r a y & Door EG 28 Gas T ray and Door Assemblies April 2006 .
W arr anty Sherwood Industries Ltd. is the manufacturer of the Envir o line of heating products. At Sherwood Industries, our commitment to the highest level of quality and customer service is the most important thing we do.
37 W arr anty 4. The stove must be operated and maintained at all times in accordance with the instructions in the Owner’s Manual. If the unit shows signs of neglect or misuse, it is not co vered under the terms of this W arr anty policy . Perf ormance problems due to operator error will not be covered by the Limited W arr anty policy .
19. The paint on the Metal Brick Liner may peel. This is due to the extreme condi tions applied to the paint during normal usage. It is not a aw and is not cov ered under warr anty . 20. Sherwood Industries Ltd. is free of liability for any damages caused by the replace or stove, as well as inconvenience expenses and materials.
39 Inst alla tion Da t a Sheet The following information must be recorded by the installer f or warr anty purposes and f uture ref erence. NAME OF OWNER: _________________________________________ ADDR.
Een belangrijk punt na aankoop van elk apparaat Enviro EG28 DV (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Enviro EG28 DV heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Enviro EG28 DV vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Enviro EG28 DV leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Enviro EG28 DV krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Enviro EG28 DV bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Enviro EG28 DV kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Enviro EG28 DV . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.