Gebruiksaanwijzing /service van het product Evolution van de fabrikant Enviro
Ga naar pagina of 36
PELLET ST OVE Ev olution PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET-BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH. Contact your building or fire officials about restrictions and installation inspection requirements in your area.
2 Introduction...................................................................................................................................3 P ellet Quality ........................................................................................
3 Introduction P ELLET Q UALITY : Pellet quality is important, please read the following: Your enviro pellet stove has been designed to burn wood pellets only.
4 Introduction I MPORTANT S AFETY D ATA : Please read this entire Owner’s Manual before installing or operating your ENVIRO Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death.
Introduction ASHES: Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be on a non-combustible floor on the ground, well away from all combustible materials pending final disposal.
Oper a ting Instructions C ONTROL B OARD F UNCTIONS : 1. AUGER TRIM: Used to change feed rates on LOW ONL Y for poorer quality fuels. Push the Auger T rim button until the number 1 and 5 lights appear on the Heat Lev el Indicator . This will increase the feed r ate to 4 seconds ON time Auger pulse.
7 Oper a ting Instructions O PERATING Y OUR P ELLET S TOVE : PRE-BURN INSTRUCTIONS : The burn pot liner holes must be clear and the liner installed properly against the ignitor tube for proper oper ation. Check the hopper for enough pellets to start the unit.
8 2-3 Days / Weekly Bi-annually or 2 T ons of Fuel Burn Pot and Liner Exhaust V ent Heat Exchanger T ubes Fresh Air Intake T ube Ash Pan Blower Mechanisms Door Glass Heat Exchanger T ubes Inside Fireb.
R outine Cleaning and Maintenance ASH PAN (weekly) This part is located under the burner , in the pedestal, and has a latching mechanism to secure i t. T o remove the ash pan, open the co ver from the right hand side, unlock the latch on the pedestal cover and pull the pan out.
R outine Cleaning and Maintenance EXHAUST VENT (biannually) This vent should be cleaned every year or after two tons of pellets. W e recommend contacting your dealer for professional cleaning. T o clean the vent pipe, tap lightly on the pipe to dislodge any loose ash.
11 Inst alla tion D ECIDING W HERE TO L OCATE YOUR P ELLET A PPLIANCE : 1.
.
13 Inst alla tion C LEARANCES TO C OMBUSTIBLES : This unit can be installed on a combustible floor due to the built in pedestal hearth pad (for example linoleum, hardwood flooring). If this unit is to be installed onto a carpeted surface, a hearth pad must be used for stability .
14 Inst alla tion H EARTH P AD P EDESTAL I NSTALLATION : Carefully place the back of the pellet appliance on the pal let and install the hearth pad. Align the holes in the hearth pad and the unit and install the four (4) screws pro vided.
15 fumes such as stairwells, cover ed breezeway , etc. 2. V ent surfaces can become hot enough to cause burns if touched by children. Non-combustible shielding or guards may be requir ed.
16 Outside fresh air is mandatory when installing this unit in airtight homes and mobile homes. A Fresh-air intake is strongly recommended for all installations . F ailure to install intake air may result in improper combustion as well as the unit smoking during power failures.
Figure 13: Corner Installation. Inst alla tion M OBILE H OME I NSTALLATION : 3" (7.5 cm) 3" (7.5 cm) Fresh Air Intake W all thimble manufactured by pellet vent manufacturer .
18 .
19 .
.
21 H EARTH M OUNT I NSTALLATION : EF 5 Existing Fireplace Clean Out T ee Fireplace Damper Location Rain Cap Seal Plate V ent Pipe (single wall stainless flex pipe or PL vent) Existing Masonary Flue Fl.
Inst alla tion E XTERIOR M OUNTED E XHAUST B LOWER : The EF5 can be equipped with an externally mounted exhaust blower . This optional kit includes all components necessary to install the exhaust blower on any vertical w all surface. 1. Remove the left hand cabinet side by removing the two (2) screws down the front.
23 Inst alla tion T YPICAL T HROUGH W ALL W ITH E XTERIOR B LOWER K IT I NSTALLATION - H ORIZONTAL T ERMINATION : .
24 EF5 Roof Sheathing Rain Cap Roof Flashing Roof Rafters Ceiling Joists V ent Pipe Exterior W all Sheathing Outside V ent T ermination Inst alla tion T YPICAL T HROUGH W ALL W ITH E XTERIOR B LOWER K IT I NSTALLATION - V ERTICAL T ERMINATION : F ollow the previous pages for through wall installations.
25 Inst alla tion T HERMOSTAT I NSTALLATION : If the unit has been placed in the HI / LOW mode, the unit will be taken to a low or idle set ting when the thermostat is not calling for heat. When the thermostat calls for heat, the unit will go to the setting that is displayed on the control board Heat Indicator .
The combustion exhaust blower is a variable speed blower controlled by the heat output button. This blower will decrease the vacuum pressure inside the stove and as the heat output button is turned down. The vacuum pressure inside the firebox will increase as the combustion exhaust blower increases in speed (higher heat output setting).
27 T roubleshooting DO NOT: ● Service the stove with wet hands. The stov e is an electrical appliance, which may pose a shock hazar d if handled improperly . Only qualified technicians should deal with possible internal electrical failures. ● Do not remove f rom the firebox any screws without penetr ating oil lubrication.
T roubleshooting 28 ü P oor Quality Fuel – Insufficient energy in the fuel to produce enough heat to keep the stove burning or operational. ü Exhaust T emperature Sensor failure. – Bypass sensor located on Exhaust Blower if stove now oper ates properly , the unit may require cleaning or a new sensor .
29 T roubleshooting 7. The convection blower will not function normally. ü Clean all grill openings at the back and below unit . ü Press the fan button; does the fan come on? Press again to verif y that the blower turns on; if , not contact your local dealer for service.
W iring Diagr am Connect Thermostat Here Red Red Red Red Brown Brown Brown Brown White White White White White 115V White 220V Blue White White Orange Orange Orange Orange Yellow Yellow Grey Grey Grey.
P ar ts List Reference Number Description Part Number 1 120°F (49°C) Ceramic F an T emperature Sensor EC-001 F an Controller Knob EC-040 Domestic Power Cor d - 115V EC-042 2 Auger Motor - 115V EF-00.
P ar ts List Reference Number Description Part Number Wire Harness 20-021 27 Glass With Gasket (356 mm x356 mm) 20-023 Thermostat Interface 20-026 28 Cabinet Side Left - Stainless Steel 20-029 28 Cabi.
33 P ar ts Diagr am - Components Evolution Domestic - Components February 2005.
P ar ts Diagr am - Steel .
35 W arr anty Sherwood Industries Ltd. gives a five year limited warrant y on all steel manufactured parts. A one-y ear warr anty is provided on all electrical components.
36 NAME OF OWNER: _________________________________________ ADDRESS: _________________________________________ _________________________________________ _________________________________________ PHONE.
Een belangrijk punt na aankoop van elk apparaat Enviro Evolution (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Enviro Evolution heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Enviro Evolution vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Enviro Evolution leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Enviro Evolution krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Enviro Evolution bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Enviro Evolution kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Enviro Evolution . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.