PN 613-001480 Rev A 1 A T -S94 V ersion 3.0.0.41 A T -8000S Switch Softwar e Release Notes Please read this document before you be gin to use the management softwa re. Caution Failure to upgrade the bootloader before the release soft ware can result in a switch that will not boot.
AT-S94 Version 3.0.0.41 Software Release Notes PN 613-001480 Rev A 2 Allied Telesis, Inc. Supported Platforms The following platforms are included in the AT -8000S family of devices: A T -8000S/16 – 16 FE ports with 1 combo 10/10 0/1000 SFP Port.
AT-S94 Version 3.0.0.41 Software Release Notes PN 613-001480 Rev A 3 Allied Telesis, Inc. What’s New in Version 3.0.0.41 New Software Features None Resolved Issues In some cases where more than one switch has the same STP Bridge Priority value in a network, the swit ch with the higher MAC address wo uld be elected as the STP root bridge.
AT-S94 Version 3.0.0.41 Software Release Notes PN 613-001480 Rev A 4 Allied Telesis, Inc. Port lock: Port security mechanism is not trigg ered for MAC violation if MAC is learned on another locked port as a secured MAC ad dress. Recommended User W ork Around: No work around Mac-group mapping and 802.
AT-S94 Version 3.0.0.41 Software Release Notes PN 613-001480 Rev A 5 Allied Telesis, Inc. Version 3.0.0.41 Upgrade Process You must have the correct software and bootloader installed o n your switch before be ginning the upgrade process to Version 3.0.
AT-S94 Version 3.0.0.41 Software Release Notes PN 613-001480 Rev A 6 Allied Telesis, Inc. 6. Assuming your switch is running the correct bootloa der, you have the correct password to extract the ats94-30041.ros software upgrade file and you know that your current bo otloader is compatible with the Version 3.
AT-S94 Version 3.0.0.41 Software Release Notes PN 613-001480 Rev A 7 Allied Telesis, Inc. 10. Before rebooting the stand alone switch or stack, you mu st change the active image, including each slave switch in the stack. To c heck the active image for each switch use the following command.
AT-S94 Version 3.0.0.41 Software Release Notes PN 613-001480 Rev A 8 Allied Telesis, Inc. 5. Select number one by pressing the ‘1’ key. The switch will respond with the following message : Begin the transmission of a previous version. Downloading code using XMODEM.
AT-S94 Version 3.0.0.41 Software Release Notes PN 613-001480 Rev A 9 Allied Telesis, Inc. Version 3.0.0.33 When the master was lost (powered do wn) the SFP port(s) on backup change d to DOWN – link changed to half duplex and remained down. This issue has been resolved.
AT-S94 Version 3.0.0.41 Software Release Notes PN 613-001480 Rev A 10 Allied Telesis, Inc. The following is a new CLI command introduced in V ersion 3.0.0.40: Version 3.0.0.38 No new features were introduced in this release. Version 3.0.0.35 No new features were introduced in this release.
AT-S94 Version 3.0.0.41 Software Release Notes PN 613-001480 Rev A 11 Allied Telesis, Inc. The following 802.1x feature enhance ments will be su pported: — Guest VLAN - This feat ure allows network adm inistrators to giv e some limited access to the network to unauthorized port s.
AT-S94 Version 3.0.0.41 Software Release Notes PN 613-001480 Rev A 12 Allied Telesis, Inc. Upgrade Procedure fr om Version 1.0.0.25 All software released after version 1 .0.0.25 requires additional FLASH sectors beyond the current amount of FLASH sectors currently allocated for the image.
AT-S94 Version 3.0.0.41 Software Release Notes PN 613-001480 Rev A 13 Allied Telesis, Inc. 2. Download the ats94-Interim image drop to the device via TFTP by using one of the followin g commands depending on your configuration: Note You must substitute the IP address of your local TFTP server.
AT-S94 Version 3.0.0.41 Software Release Notes PN 613-001480 Rev A 14 Allied Telesis, Inc. 7. Before rebooting the stand alone switch or stack, you mu st change the active image, including each slave switch in the stack. To c heck the active image for each switch use the following command.
AT-S94 Version 3.0.0.41 Software Release Notes PN 613-001480 Rev A 15 Allied Telesis, Inc. 14. Before rebooting the stand alone switch or stack, you mu st change the active image, including each slave switch in the stack. To c heck the active image for each switch use the following command.
AT-S94 Version 3.0.0.41 Software Release Notes PN 613-001480 Rev A 16 Allied Telesis, Inc. Contacting Allied Telesis This section provides Allied Teles is contact information for technical support as well as sales and corporate information. Online Support You can request technical support online by accessing the Allied Tel esis Knowledge Base: www.
Een belangrijk punt na aankoop van elk apparaat Allied Telesis 613-001480 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Allied Telesis 613-001480 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Allied Telesis 613-001480 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Allied Telesis 613-001480 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Allied Telesis 613-001480 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Allied Telesis 613-001480 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Allied Telesis 613-001480 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Allied Telesis 613-001480 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.