Gebruiksaanwijzing /service van het product 86222-10 van de fabrikant Allied Telesis
Ga naar pagina of 14
Simply connecting the world Patch Release Note Patch 86222-10 For Rapier Switches and AR800 Series Modular Switching Routers Intr oduction This patch rel ease note lists the issues addres sed and enhancements made in patch 86222-10 for Software Release 2.
2 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J Some switch chip r egister settings have been optimised to impr ove the provision of CoS with the newer r evision of switching silicon. Featur es in 86222-09 Patch file details for Patch 86222-0 9 are listed in T able 2.
Patch 86222-10 For Rapier Switches a nd AR800 Series Modula r Sw itching Routers 3 Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J A configuration pr oblem prevented trunk ing of gigabit ports at 100Mbit speeds. This issue has been resolved.
4 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J The dot1dBridge MIB implementation now complies with RFC1493. Featur es in 86222-07 Patch file details for Patch 86.
Patch 86222-10 For Rapier Switches a nd AR800 Series Modula r Sw itching Routers 5 Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J Debug messages ar e no longer generate d when a Q.931 Advise of Charge Notification message is re ceived.
6 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J The T rigger Facility was generating a tr ap with variable { 0 0 }, and was not documented in the A TI enterprise MIB.
Patch 86222-10 For Rapier Switches a nd AR800 Series Modula r Sw itching Routers 7 Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J A switch port that was transmitting STP B PDUs and also mirr oring its transmit traf fic to the mirror port caused a fatal err or .
8 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J A39 copper uplink modules in the Rapier G6 sometimes experienced spurious link up or link down ev ents. This issue has been r e solved. The enterprise MIB now supports objects for power supply monitoring.
Patch 86222-10 For Rapier Switches a nd AR800 Series Modula r Sw itching Routers 9 Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J When lar ge numbers of sessions were being handled the firewall would become overly aggr essive in r estricting new sessions.
10 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J correctly when only one byte has been specified. The CRL update time is now displayed correctly in hours. If the username and password parameters ar e present the location parameter must be pr esent and appear before the username and password parameters.
Patch 86222-10 For Rapier Switches a nd AR 800 Series Modular Switching Routers 11 Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J DNS response packets wi th corrupt length fields were causing a fat al error . This issue has been r esolved.
12 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J The SHOW CPU command sometimes di splayed incorrect CPU util isation figures. T y pically a value of about 74% was reported when in fact the CPU was almost idle. Thi s issue has been r esolved.
Patch 86222-10 For Rapier Switches a nd AR 800 Series Modular Switching Routers 13 Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J Repeated addition and deletion of an addr ess with the V ALID parameter set to or fr om an IPV6 interface caused a fatal err or .
14 Patch Release Note Patch 86222-10 for Software R elease 2.2.2 C613-10319 -00 REV J.
Een belangrijk punt na aankoop van elk apparaat Allied Telesis 86222-10 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Allied Telesis 86222-10 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Allied Telesis 86222-10 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Allied Telesis 86222-10 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Allied Telesis 86222-10 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Allied Telesis 86222-10 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Allied Telesis 86222-10 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Allied Telesis 86222-10 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.