613-001382 Rev. E 8100L and 8100S Series Fast Ethernet Switches A T -8100L/8 A T -8100L/8POE A T -8100L/8POE-E A T -8100S/24C A T -8100S/24 A T -8100S/24POE A T -8100S/48 .
Copyright 2012 Allied Telesis, Inc. All rights reserved. No part of this pub lication may be reproduced without prior wr itten permission from Al lied Telesis, Inc. Allied Telesis and th e Allied Telesis logo are trademarks of Allied Telesis, Incor porated .
3 Electrical Safety and Emissions S tandards This product meets the following standards. RFI Emissions: FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-3-3, VCCI Class A, C-TICK, CE EMC (Immunity): EN55024 Electrical Safety: EN60950-1 (TUV), UL 60950-1 ( C UL US ) U.
4 T ranslated Safety S tatements Important: The indicates that translations of t he safety statement are available in the PDF document “Translated Safety Statements” posted on the Allied Telesis website at www.
5 Preface ....................... ........... ........... .............. ........... ............ ........... ........... ........... ........... . ........ ........... ........... .............. ... 13 Document Conventions ............. .............
Contents 6 Port Pinouts ................. ........... ........... ........... ............ .............. ........... ........... ........... ...... ... ........... ........... ........... .......... 38 SFP Slots ........... ........... ........... ..
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 7 Certifications ............. .............. .............. .............. .............. .............. ........... .............. ..... .................. ........... ....
Contents 8.
9 Figure 1: Front Panels of the 8100L Series Switches.......... .............. ........... .............. .............. ............. .................. ............. 23 Figure 2: Networking Ports and SFP Slots on the 8100L Seri es Switches......... .
Figures 10.
11 Ta b l e s Table 1: Hardware Features of the 810 0L Series Switc hes .......... ........... ........... ............ ........... .............. .. ......... .............. .. 22 Table 2: Hardware Features of the 810 0S Twisted Pair Series .........
Tables 12.
13 Pr eface This guide contains the installat ion instructions for the 8100L and 810 0S Series of Fast Ethernet switches. This manual explains how to install the units as stand-alone devices.
Preface 14 Document Conventions This document uses the following conventions: Note Notes provide additional informatio n. Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data. Warning Warnings inform you that performing or omitting a sp ecific action may result in bodily injury.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 15 Contacting Allied Telesis If you need assistance with this prod uct, you may contact Allied Telesis technical support by going to the Suppo rt & Services section of the Allied Telesis web site at www.
Preface 16.
17 Chapter 1 Overview This chapter contains the following sections: “Features” on p age 18 “8100L Series Switches” on page 22 “8100S T wisted Pair Series Switches” on p age 24 .
Chapter 1: Ove rview 18 Features Here is a list of the switches and the ir features: 8100L and 8100S Models Here are the 8100L and 8100S Series switches: AT-8100L/8 AT-8100L/8POE AT-8100L/.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 19 Power over Ethernet Here are the basic features of Power over Ethernet (PoE): PoE and PoE+ supported on the 10/10 0B.
Chapter 1: Ove rview 20 Stacking Ports Here are the basic features of the stacking ports on the 8100S Series switches: Two stacking ports per switch 10Gbps total bandwidth High-definition .
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 21 Fanless Models Here are the 8100L and 8100S Series switches tha t do not have fans: AT-8100L/8 Switch AT-8100S/2.
Chapter 1: Ove rview 22 8100L Series Switches The three models in the 8100L Series a re listed here: AT-8100L/8 AT-8100L/8POE AT-8100L/8POE-E Hardware Features Table 1 lists the hardware features of the 8100L Series switches.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 23 Front Panels The front panels of the 8100L Series switches are shown in Figure 1.
Chapter 1: Ove rview 24 8100S Twisted Pair Series Switches The five twisted pair models in the 8100S Series are listed here: AT-8100S/24C AT-8100S/24 AT-8100S/24POE AT-8100S/48 AT-8100S/48POE For information on the fiber o ptic models, refer to “8100S Fiber Optic Series Switches” on page 27.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 25 Front Panels The front panels of the 8100S Series switches are shown in Figure 3.
Chapter 1: Ove rview 26 Front Panel Components Figure 4 identifies the Fast and Gigabit Ethern et networking ports and the SFP slots on the 8100S Series switches.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 27 8100S Fiber Optic Series Switches The three fiber optic models in th e 8100S Series are listed here: AT-8100S/16F8-SC AT-8100S/16F8-LC AT-8100S/24F-LC Hardware Features Table 3 lists the hardware featu res of the fiber optic 8100S Series switches.
Chapter 1: Ove rview 28 Front Panels The front panels of the fiber optic switches are shown in Figure 5 an d Figure 6 on page 29. Figure 5. Front Panels of the 8100S Fiber Optic Series Switches AT-810.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 29 Figure 6. Front Panels of the 8100 S Fiber Optic Series Switches (Continued) Fiber Optic Ports Table 4 lists the general specifications of the fiber optic ports on the fiber optic switches.
Chapter 1: Ove rview 30 Back Panels Figure 7 shows the back panels of the single power supply switches. Figure 7. Back Panels of the Single Power Supply Switches AC Power Connector AT-8100L/8 and AT-8.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 31 Figure 8 shows the back panels of t he dual po wer supply switches. Figure 8.
Chapter 1: Ove rview 32 Management Panels Figure 9 identifies th e components in the management panel on the 8100L Series switches. Figure 9. 8100L Series Management Panel Figure 10 identifies the components in the management panel on the 8100S Series switches.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 33 Model Naming Conventions The hardware features of the switche s are represented by the letters a nd numbers in the model names. The con ventions for the twisted pair 8100L and 8100S Series switches ar e identified in Figure 11 .
Chapter 1: Ove rview 34 The conventions are defined in Table 6. Table 6. Model Naming C onventions for the Fiber Optic 8100S Series Switches Convention Definition 1 This is the product name. 2 The letter “S” indicates that the model is stackable .
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 35 10/100Base-TX Twisted Pair Ports The switches have 8, 24, or 48 10/100Ba se-TX ports. Speed The ports can operate at either 10 or 100 Mbps. The speeds may be set manually using the management so ftware or automatically with Auto- Negotiation (IEEE 802.
Chapter 1: Ove rview 36 Maximum Distance The ports have a maximum operating distance of 100 meters (328 feet). Power Over Ethernet The 10/100Base-TX ports on the AT-8100S/24POE and AT-8100S/ 48POE Swi.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 37 10/100/1000Base-T Twisted Pair Ports The switches have two 10/100/1000B ase-T ports. These po rts are paired with SFP slo ts to form combo ports. Speed The ports can operate at 10, 100, or 1000 Mbps.
Chapter 1: Ove rview 38 The MDI and MDI-X settings do not apply when the ports are operating at 1000 Mbps. Maximum Distance The ports have a maximum operating distance of 100 meters (328 feet). Power Over Ethernet The 10/100/1000Base-T ports on the A T -8100L/8POE, A T -8100S/24POE and A T -8100S/48POE Switches do not support PoE.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 39 SFP Slots The switches have two slots for 100Mbp s 100Base-FX or 1000Mbp s 1000Base-SX/LX fiber optic transceivers.
Chapter 1: Ove rview 40 Port speed is an exception to th e s hared settings o f the twisted pair port and SFP slot of a combo por t. If you disable Auto-Negotiat ion on the twisted pair port and set the speed and duplex mode manually, the switch reactivates it when an SFP module establishes a link with an end node.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 41 Power Over Ethernet The AT-8100L/8POE, AT-8100L/8POE-E, AT-8100S/24POE, and AT-8100S/48POE Switches feature Power over Ethernet (PoE) on the 10/ 100Base-TX ports.
Chapter 1: Ove rview 42 Powered Device Classes Powered devices are grou ped into the five classes listed in Table 10 on page 42. The classes are based on t he amount of power the devices require. The switches support all five classes. Power Budget The AT-8100L/8POE and AT-8100L/8POE-E Switches have a power budget of 180 watts.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 43 The switch can handle different power re quirements on different ports.
Chapter 1: Ove rview 44 Wiring Implementation The IEEE 802.3af standard defines two me thods by which a PSE, such as the switch, can transmit DC power over t wisted pair cables to PDs. These methods, known as modes A and B, identify the wire strand s the switch should use when sending DC powe r to a PD.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 45 Stacking Ports The 8100S Series switches may be used as stand-alone units or as part of a virtual stack in which the units are intercon nected via the stacking ports on the front panels.
Chapter 1: Ove rview 46 eco-friendly Button You may turn off the port L EDs to conserve electricity when you are not monitoring the switch. The LEDs ma y be toggled with the eco-friendly button on the front panel of the switch or the ECOFRIENDLY LED and NO ECOFRIENDLY LED commands in the Gl obal Configuration mode of the command line interface.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 47 LEDs Here are descriptions of the switch’s LEDs. 10/100Base-TX Twisted Pair Port LEDs The 10/100Base-TX twisted pair ports have link/activity and duplex mode LEDs. Figure 13.
Chapter 1: Ove rview 48 Here are the LED guidelines: The LEDs do not display port speed. That information may be displayed using the management softwa re. The LEDs do not display PoE information on the AT -8100S/24POE and AT-8100S/48POE Switches.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 49 100Base-FX Port LEDs Each of the 100Base-FX ports on the AT-8100S/16F8 -SC, AT-8100S/ 16F8-LC, and AT-8100S/24F-LC Switches has a single LED, labeled L/A for Link/Activity.
Chapter 1: Ove rview 50 SFP Slot LED Each SFP slot has one LED. Figure 16. SFP Slot LEDs The SFP slot LED is described in Table 14. Table 14. SFP Slot LED LED State Description Link/Activity Off The SFP slot is empty or the SFP module has not established a link to a network device.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 51 Stacking Port LEDs Each stacking port has one link LED labelled LINK/ACT. Figure 17. Stacking Port S1 and S2 LEDs The stacking port LED is described in T able 15. Note The stacking port LEDs do not indicate pa cket activity.
Chapter 1: Ove rview 52 Figure 18. Stack ID LED The 8100L Series switches do not support stacking, but they have stack ID LEDs and can be assigned ID nu mbe rs because they have the same management software as the 8100S Series switches. Given that yo u cannot stack 8100L Series switches, the correct ID number for these units is always “0.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 53 Console Port The Console port is used t o configure the features and paramet er settings of the switch. This type of management uses serial RS-232 and is commonly referred to as local or out-of-band management because it is not conducted over your network.
Chapter 1: Ove rview 54 Power Supplies The 8100L Series switches have one AC power supply. The 8100S Series switches have two AC or DC power s upplies, except for the AT-8100S/ 24C Switch, which has one AC power sup ply. The supplies are not field- replaceable and each has a separate AC or DC connector on the back panels.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 55 Power Connectors The 8100S Series switches have two AC or DC power supply sockets o n the back panels, except for the AT-8100S/24C Switch, which h as one AC power supply socket.
Chapter 1: Ove rview 56.
57 Chapter 2 Beginning the Installation The chapter contains the following sections: “Installation Procedures” on p age 58 “Reviewing Safety Precautions” on p age 59 “Choosing a .
Chapter 2: Be ginning the Install ation 58 Installation Procedures You may install the switch on a table or in an e quipment rack. Perform these procedures to install the switch on a table: “Rev.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 59 Reviewing Safety Precautions Please review the followin g safety precautions before yo u begin the installation procedure.
Chapter 2: Be ginning the Install ation 60 Warning Class I Equipment. This equipment must be earthed. Th e power plug must be connected to a properly wired earth ground socket outlet. An improperly wired socket out let could place hazardous voltages on accessib le metal p arts.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 61 Caution Risk of explosion if battery is re placed by an incorrect type. Replace only with the same or equivalent type recommended b y the manufacturer. Dispose of used batter ies according to the manufacturer’s instructions.
Chapter 2: Be ginning the Install ation 62 Warning Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be give n to supply connections other than direct connections to the branch circuit s (e.g., use of power strip s).
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 63 Choosing a Site for the Switch Observe these requirements when planning the installation of t he switch. If you plan to install the switch in an equipment rack, th e rack should be safely secured so that it will not tip over.
Chapter 2: Be ginning the Install ation 64 Unpacking the Switch Refer to the following tables to verify th e contents of the shipping containers of the switches: For the A T -8100L/8, A T -8100L/8POE, and A T -8100L/8POE-E Switches, refer to Figure 19 on p age 65.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 65 Figure 19. Components of the 8100L Series Switches One AT-8100L/8, AT-8100L/8POE, or AT-8100L/8POE-E Switch One short rack mounting bracket One long rack mounting bracket One 2 m (6.
Chapter 2: Be ginning the Install ation 66 8100S Series Switches The 8100S Series switches, except the A T -8100S/24C Switch, come with the components listed in Figure 20. Figure 20. Components of the 8 100S Series Switches One 8100S Series switch T wo rack mounting brackets One 2 m (6.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 67 AT-8100S/24C Switch The AT-8100S/24C Switch comes with the items listed in Figure 21. Figure 21. Components of the AT-8100S/24C Switch One AT-8100S/24C Switch One short rack mounting bracket One 2 m (6.
Chapter 2: Be ginning the Install ation 68.
69 Chapter 3 Installing the Switch on a T able or in an Equipment Rack The procedures in this chap ter are: “Installing the Switch on a T able or Desktop” on page 70 “Installing the Swit.
Chapter 3: Installi ng the Switch on a Table or in an Equipment Rack 70 Installing the Switch on a Table or Desktop You may install the switch on a table or d esktop. Here are the guidelines to selecting a site: The table should be level and stable.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 71 Installing the Switch in an Equipment Rack This procedure requires the following it ems: Eight bracket screws (inclu.
Chapter 3: Installi ng the Switch on a Table or in an Equipment Rack 72 3. Turn the switch over. 4. For all switches except the AT-8100L/8, AT-8100L /8POE, and AT-8100S/24C Switches, secure the two ra ck mount brackets to the sides of the switch using the eigh t bracket screws included with the unit.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 73 Figure 25. Attaching th e Brackets to Install the Switch in an Equipment Rack (Continued) The AT-8100L/8, AT-8100L/8POE, AT-8100L/8POE-E, and A T -8100S/ 24C Switches come with one short bracket and one long bracket.
Chapter 3: Installi ng the Switch on a Table or in an Equipment Rack 74 Figure 26. Attaching the Brackets to 8100L a nd AT-8100S/24C Switches for Equipment Rack Installation.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 75 Figure 27. Attaching the Brackets to 8100L and AT-8100S/24C Switches for Equipment Rack Installation (Continued) 5. While another person holds the switch in the equipment rack, secure it using standard equipment rack scre ws (not provided).
Chapter 3: Installi ng the Switch on a Table or in an Equipment Rack 76.
77 Chapter 4 Cabling the Networking Ports This chapter contains the following pro cedures: “Cabling the T wisted Pair and Fiber Optic Port s” on page 78 “Installing Optional SFP T ransce.
Chapter 4: Cablin g the Networking Ports 78 Cabling the Twisted Pair and Fiber Optic Ports This section contains the guidelin es to cabling the twisted pair and fib er optic ports.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 79 The 10/100/1000Base-T ports mu st be set to Auto-Negotiation, the default setting, to operate at 1000Mb ps. The default duplex mode set ting for the ports is Auto-Negotiation .
Chapter 4: Cablin g the Networking Ports 80 Installing Optional SFP Transceivers Review the following guidelines bef ore installing optional SFP transceivers in the switch: The SFP slots are part of combo ports, with 10/100/1000Base-T ports. For operational information, refer to “SFP Slots” on p age 39.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 81 Figure 29. Removing the Dust Plug from an SFP Slo t 2. Remove the transceiver from its shipping containe r and store the packaging material in a safe loca tion.
Chapter 4: Cablin g the Networking Ports 82 Figure 31. Removing the Dust Cover from t he SFP Module 6. Verify that the handle on the SFP transceiver is in th e upright position, as shown in Figure 32.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 83 7. Connect the fiber optic cable to the SFP module, as shown in Figure 33. Figure 33. Connecting the Fiber Optic Cable to the SFP Module 8. Repeat this procedure if you have another SFP tr ansceiver to install.
Chapter 4: Cablin g the Networking Ports 84.
85 Chapter 5 Powering On the Switch This chapter contains the following pro cedures: “Powering On an AC Switch” on page 86 “Powering On a DC Switch” on page 91 “Setting the S tac.
Chapter 5: Po wering On the Swi tch 86 Powering On an AC Switch To power on an AC switch, connect the power cords to the connectors on the back panels and to the appro priate power sources.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 87 Consider the following items as you po wer on the switch: Connecting the two power cords to power sources that are on different circuits will provide power redundancy to the switch in the event a circuit fails.
Chapter 5: Po wering On the Swi tch 88 The base port LEDs are on in phases 1 and 2 if they a re connected to live network devices. Otherwise, they are off. The 10/100/1000 Base-T port LEDs are on in phase 1 regardless of whether they are connected to active network devices .
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 89 Figure 35. Switch Initialization Messag es CFE-NTSW-5 .0.0 for BCM9562 18 (32bit,SP, BE,MIPS) Build Date: Wed Jul 23 13 :47:51 PD T 2008 (jwong @tirami su) Copyright (C) 2000, 20 01, 2002, 2 003, 2004, 2005 Broadc om Corporat ion.
Chapter 5: Po wering On the Swi tch 90 Figure 36. Switch Initia lization Messages (Continued) After the switch has initialized it s management software, go to “Setting the Stack ID Number” on page 95 to co nfirm its ID number. Initializi ng Monitor .
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 91 Powering On a DC Switch Perform this procedure to power on a DC 81 00S Series switch: Warning As a safety preca ution, install a circuit breaker with a minimum value of 15 Amps between the equipment and the DC power source.
Chapter 5: Po wering On the Swi tch 92 Figure 37. DC Terminal Block 3. With a 14-gauge wire-stripping tool, strip the three wires in the tray cable coming from the DC input power source to 8 mm 1mm (0.31 in., 0.039 in.), as shown in Figure 38 on p age 92.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 93 Figure 39. Inserting Wires into the DC Te rminal Block 5. Connect the positive feed wire to the te rminal block marked + (plus). 6. Connect the negative feed wire to the terminal block marked - (minus).
Chapter 5: Po wering On the Swi tch 94 computer with a terminal emulator program conne cted to the Console port on the switch, you will see the messages in Figure 35 on p age 89 to Figure 36 on p age 90. 11. Repeat this procedure to power on the secon d power supply.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 95 Setting the Stack ID Number After the switch has i nitialized it s manageme nt software, examine the Stack ID LED on the front panel and do on e of the following: If the LED is displaying “0,” the installation procedure is complete.
Chapter 5: Po wering On the Swi tch 96 2. Connect the other end of the cab le to an RS-232 port on a terminal or PC with a terminal emulator program. 3. Configure the terminal or termi nal emulator program as follows: Baud rate: 9600 bps (The ba ud rate of the Console Port is adjustable from 1200 to 115200 bps.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 97 3. Connect the other end of the cable to the Ethernet port on your computer. 4. Start the Telnet client on your computer and sp ecify the switch’s IP address, 169.254.1.
Chapter 5: Po wering On the Swi tch 98 This confirmation prompt in Figure 43 is displayed . Figure 43. STACK Command Confirmation Prompt Caution The STACK command resets the switch. If the switch is already connected to a live network, some network t raffic may be lost.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 99 Starting a Management Session You may use the following methods and tools to manage stand-alone 8100L and 8100S Series s.
Chapter 5: Po wering On the Swi tch 100 Telnet management sessions are not secure and are vulnerable to snooping because the pa ckets exchanged between t he switch and your workstation are sent in plain text. Th e security of the switch may be jeopardized if an intruder captures the packet containing your userrname and password.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 101 You need to assign your management workstation an IP address in the 169.254. n . n subnet or your workstation must have access to that subnet through routing devices.
Chapter 5: Po wering On the Swi tch 102 For instructions on the command line interf ace and the PORT parameter, refer to the A T -8100 Series AlliedWare Pl us Command Line Interface User ’s G uide .
103 Chapter 6 T r oubleshooting This chapter contains suggestions on ho w to trou bleshoot the switch if a problem occurs. Note For further assistance, please contact Allied Te lesis Technical Support at www.alliedtelesis.com/support . Problem 1: The Stack ID LED on the front of the switch is off.
Chapter 6: Tro ubleshooting 104 Verify that the network device con nect ed to the twisted pair port is powered on and is operating properly. Try connecting another net work device to th e twisted pair port with a different cable.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 105 Problem 5: Network performance between a twisted pair port on the switch and a network device is slow. Solution: There might be a duplex mode mismat ch between the port and the network device.
Chapter 6: Tro ubleshooting 106.
107 Appendix A T echnical Specifications Physical Specifications Dimensions (H x W x D) Weights Table 17. Product Dimensions AT-8100L/8 AT-8100L/8POE AT-8100L/8POE-E AT-8100S/24C 4.4 cm x 33.0 cm x 20.3 cm (1.7 in. x 13.0 in. x 8.1 in.) A T -8100S/24 A T -8100S/48 AT-8100S/24F-LC 4.
Appendix A: Technica l Specifications 108 Ventilation Environmental Specifications AT-8100S/16F8-LC 4.4 kg (9.75 lb.) AT-8100S/24F-LC 4.4 kg (9.75 lb.) Table 19. Ventilation Requiremen ts Recommended Minimum Ventilation on All Sides 10 cm (4.0 in) Table 18.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 109 Power Specifications Maximum Power Consumptions Input Voltages Table 22. Maximum Power Consumptions AT-8100L/8 9.1 watts AT-8100L/8POE 229.1 watts AT-8100L/8POE-E 229.1 watts AT-8100S/24C 18.
Appendix A: Technica l Specifications 110 Certifications Quality and Reliability A T -8100S/48 AC model: 100-240 VAC, 1.0 A maximum, 50/60 Hz per input A T -8100S/48POE AC model: 100-240 VAC, 3.0 A maximum, 50/60 Hz per input AT-8100S/16F8-SC AC model: 100-240 VAC, 1.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 111 RJ-45 Twisted Pair Port Pinouts Figure 45 illustrates the pin layout of the RJ-45 connectors and p orts. Figure 45. RJ-45 Socket Pin Layout (Front View) Table 26 lists the pin si gnals for 10 and 100 Mbps.
Appendix A: Technica l Specifications 112 Table 27 lists the pin signals when a p ort operating at 1000 Mb ps. Fiber Optic Port Specifications Table 28 lists the specifications of the 100Base-FX fibe r optic ports on the AT-8100S/16F8-SC Switch. Table 27.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 113 Table 29 lists the specifications of the 100Base-FX fiber optic ports on the AT-8100S/16F8-LC and AT-8100S/24F-LC Switche s. Receiver Wavelength 1310 nm Sensitivity Maximum: -31.
Appendix A: Technica l Specifications 114 RJ-45 Style Serial Console Port Pinouts Table 30 lists the pin signals of the RJ-45 style se rial Console port. Stacking Port Pinouts Figure 46 illustrates the pin layout of th e S1 and S2 stacking ports. Figure 46.
Stand-alone Swit ch Installation Gu ide for 8100L and 8100S Se ries Switches 115 4 Transmit data1+ Receive data1+ 5 Ground Ground 6 Transmit data1- Receive data1- 7 Receive data0+ Transmit data0+ 8 Ground Ground 9 Receive data0- Transmit data 0- 10 Not connected Not connected 11 Ground Ground 12 to 19 Not connected Not connected Table 31.
Appendix A: Technica l Specifications 116.
Een belangrijk punt na aankoop van elk apparaat Allied Telesis AT-8100S/48POE (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Allied Telesis AT-8100S/48POE heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Allied Telesis AT-8100S/48POE vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Allied Telesis AT-8100S/48POE leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Allied Telesis AT-8100S/48POE krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Allied Telesis AT-8100S/48POE bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Allied Telesis AT-8100S/48POE kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Allied Telesis AT-8100S/48POE . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.