Gebruiksaanwijzing /service van het product SILENCE van de fabrikant Faber
Ga naar pagina of 29
installation guide and user manual room-sealed built-in gas-fireplace 40 010 527 02 37 SILENCE FEELING WHISPER SPECTRA NO V A CADRA NO V A MISTY Saturnus 8 NL-8448 CC Heerenv een P ostbus 219 NL-8440 AE Heerenveen T .
1 CONTENTS 1. INTR ODUCTION 2 2. SAFETY INSTRUCTIONS 3 3. INST ALLATION REQUIREMENTS 5 3.1 Builders opening and surround 5 3.2 Requirements outlet and exhaust 8 4. INST ALLATION-INSTRUCTIONS 17 4.1 Gas connection 17 4.2 P reparation of the appliance 17 4.
UK/IRL 2 UK/IRL 3 1. INTR ODUCTION N ote: these instructions should be read carefully and retained for future reference. Please leave these instructions with the user .
UK/IRL 5 UK/IRL 4 Building Regulations and Standards issued as relevant by the Department of the Environment or the Scottish Development Department. In the Republic of Ireland installation should be c.
L M F I C B A J E D G K H Builders opening (mm) F eeling Silence Whisper S pectra Cadra Misty Nov a No va A Opening width* 960 960 780 780 680 710 B Opening height* 649 649 705 698 798 890 C Opening depth* 385 385 430 430 430 370 Shelf dimensions (combustible) D Min.
UK/IRL 9 UK/IRL 8 3.2 Flue requirements The appliance is of the type C11/C31. The appliance will need to be supplied with the approv ed flue pipes and terminal, it is not possible to supply your own. The minimum effective height of the flue system must be 0.
UK/IRL 012 3 4 5 6 0 XXXXXXX XXXXXX XXXXX XXXX XXX XX X 1 30 0 0 0 0 0 0/X* 2 3 0 3 0 0 0 0 0 0 3 4 54 53 0 0 0 0 0 4 4 54 53 0 0 0 0 0 5 5 05 04 54 53 0 0 0 6 5 05 04 54 53 0 0 0 7 6 06 06 05 05 04 5.
UK/IRL 13 3. 2 Flue requirements (continuing) 3.2.1 T erminal position V erify if the required terminal position meets the local installation regulations regarding disturbance, good functioning and ventilation. (Also see: safety requirements). N ote: The terminal must be located so that the outlet is not obstructed.
T able 6 UK/IRL 15 UK/IRL 14 Dimension T erminal position Balanced flue room sealed (kW input 7.5 kW expressed in net) N atural draught A Direct below an opening, airbrick, 300 mm opening windows, etc. B Abov e an opening, airbrick, 300 mm opening window ect.
UK/IRL 17 UK/IRL 16 4. INSTRUCTIONS FOR INST ALLA TION 4.1 Gas connection 1. Installation pipes should be in accordance with BS 6891. Pipe work from the meter to the appliance must be of adequate size. 2. The complete installation including the meter must be tested for soundness and purged as described in the above code.
UK/IRL 19 UK/IRL 18 4.2 P reparing the appliances Widescreen and Whisper (continuing) 4. T ake the box with the log set out of the combustion chamber . 5. Place the right flue restrictor in the combustion chamber . T o determine the right flue restrictor , see chapter 3.
UK/IRL 21 4.3 P reparing the appliance Misty (continuing) 4. T ake the box with the log set out of the combustion chamber . 5. Place the right flue restrictor in the combustion chamber . T o determine the right flue restrictor , see chapter 3. fig.
UK/IRL 23 UK/IRL 22 4.4 P reparing the appliances Spectra Nova/C adra N ova (continuing) 4. T ake the box with the log set out of the combustion chamber . 5. Place the right flue restrictor in the combustion chamber . T o determine the right flue restrictor , see chapter 3.
UK/IRL 25 UK/IRL 24 4.5 Fitting the firebox (continuing) 8. Spr ead, the bags of embers (imitation ashes) provide with the appliance over the burner tray . Attention! N o embers on the grid end between the logs and the burner tray . 9. Before placing the glass; check the glass sealing rope is in good condition and makes an effective seal.
UK/IRL 27 UK/IRL UK/IRL 5. INST ALLA TION OF THE FLUE 5.1 Connections with use of concentric duct material - Build the system starting from the appliance on. - Make a hole of ø 153 mm for the wall or roof mounted terminal. - Make sure you place the pipes in the right direction, the narrow end towards the appliance.
UK/IRL 29 UK/IRL 28 UK/IRL UK/IRL 5.2 Connection onto an existing chimney (continuing) 5. F ixing the chimney sealing plate (D) and place the 150 mm grommet into the hole of the sealing plate. 6. F ix the sealing plate air tight into the builders opening (use the isolation rope from the chimney connection set to make the plate air tight).
UK/IRL 31 UK/IRL 30 UK/IRL UK/IRL 3. Connect the wires to the gas valve (see fig. 22). 4. Check that there are batteries in the transmitter . See "Replacing batteries", see chapter 10.4.4. 5. Set the on/off switch on the receiver to "on".
UK/IRL 33 UK/IRL 32 UK/IRL UK/IRL 6.3 Functional balanced flue check 1. Set the appliance on max. input. 2. V erify the flame picture, this means no flames against the window , the flame have to come besides the logs, if not check the log layout. 3. Check if the flames are yellow after 10 minutes of operation.
UK/IRL 35 UK/IRL 34 8. SERVICING T o ensure safe, efficient operation of the appliance, it is necessary to carry out routine servicing at regular intervals. It is recommended, that the fire is inspected/serviced by a competent person at least once a year .
UK/IRL 37 UK/IRL 36 8.1.4 Burner tray assembly 1. Remov e the front, glass, log set, grid and burner tray cover . 2. Break the gas supply at the control valve. 3. U nscrew the burner assembly and take them out of the combustion chamber . A. Pilot assembly B.
UK/IRL 39 UK/IRL 38 UK/IRL UK/IRL 8.1.7 Combustion test A BS7967 combustion analysis check should be carried out using an analyser to BS7927 positioned in the flue outlet. A Ratio of CO/CO2 should be less than 0.01 within 30 minutes. (100ppm CO per 1% CO2).
Whisper F eeling S ilence Misty S pectra Cadra Nov a Nov a Description Company Company Company Company Company Company part par t par t part par t par t Surround antracite A9271453 A9270053 A9267753 A.
Country UK/IRL UK/IRL Category II 2H3+ II 2H3+ Model type C11 0f C31 C11 0f C31 Heat input Hi kW 7.5 7.5 Efficiency class 2 2 NOX class 4 4 T ype of gas G20 G30 Inlet pressure mbar 20 30/37 Gas rate 15 °C / 1013 mbar m3/h 800 231 kg/h 540 g Reference burner pressure mbar 13 25 Injector size mm 3x 1.
UK/IRL 45 UK/IRL 44 UK/IRL UK/IRL UK/IRL USER GUIDE 8.3 TECHNICAL DA T A Roundscr een Misty Country UK/IRL UK/IRL Category II 2H3+ II 2H3+ Model type C11 0f C31 C11 0f C31 Heat input Hi kW 8,5 8,5 Eff.
UK/IRL 47 UK/IRL 46 IMPORT ANT A suitable Fir eguard conforming to BS6539 and BS6778 should be used with this appliance to protect children, the elderly or infirm. Care should also be taken with pets. In your own interest and that of safety , all gas appliances must be installed by competent persons.
UK/IRL 49 UK/IRL 48 Knob A The { is the OFF position preventing any gas from passing through the control valve to either the pilot burner or to the main burner .
UK/IRL 51 UK/IRL 50 10.4.1 T o light 1. P ush in and turn the control knob (A) from { anticlockwise to the setting (small flame). Y ou will hear a ignition click. Check that the pilot is lit (if not repeat). 2. Continue to hold in the control knob for a further ten seconds to ensure that the pilot flame is stable.
UK/IRL 53 UK/IRL 52 10.4.3 Setting the right transmission code he receiver has to learn the code from the transmitter , which is already done at the factory . Ho wever the code disappears if the receiver is disconnected from the mains for a longer period, 1.
UK/IRL 55 UK/IRL 54 UK/IRL UK/IRL UK/IRL UK/IRL 12. DISPOSAL OF THE P A CKAGING AND THE APPLIANCE The appliance packaging is recyclable. The packaging could include the following materials: - cardboard; - CFC-free foam (soft); - wood; - plastic; - paper .
Een belangrijk punt na aankoop van elk apparaat Faber SILENCE (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Faber SILENCE heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Faber SILENCE vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Faber SILENCE leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Faber SILENCE krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Faber SILENCE bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Faber SILENCE kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Faber SILENCE . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.