Serial Bus for Navy Gateway GW0016 • Visual/Audible Alert messages • Easy Installation • W aterproof Connections • Easy to read Digital displays • Multiple Interfaces IS0210 rev .
Table of Contents Quick Reference page 2 turn system on/off page 2 turn on instrument lighting page 2 change lighting intensity page 2 disable audible alarm in Normal Mode page 2 change LCD display pa.
Navy Gateway (GW0016) System Manual The system consists of: • One Gateway box to interface with engine and external senders and sensors. • One 4” Tachometer with Fuel Monitor • Various 2” in.
Gateway System Specifications: Operation voltage: +12 V DC or +24 V DC +12 V DC (10 V DC (Min.) to 16 V DC (max.)) +24 V DC (20 V DC (Min.) to 32 V DC (max.
Several alarm conditions may also be displayed in the LCD display when needed: 1 Low fuel 2 Low oil pressure 3 Low voltage Alarm messages will be displayed on the tachometer LCD display.
b) Imperial gallons. Display will show c) Liters. Display will show Leaving the display in one of the items above while the “Mode” button is pressed and held for more than one second will save the selected units. Trip Fuel Consumed Displays fuel consumed since last reset.
Holding the “Mode” button for more than one second while the display is showing “ADJXXX.X” will set the amount in the display “XXX.X” into the Trip Fuel Consumed and return to the Trip Fuel Consumed function.
When the “Fuel Remaining” reaches this amount, the “Low Fuel” alarm will sound and a warning LED will flash in the display. The display will automatically go into “set” mode to allow the operator to reset the alarm value to a lower value to turn off the alarm if desired.
LCD Alarm Condition Displays. Alarm messages will be displayed on the Tachometer LCD display. All messages will be displayed until the problem is corrected, or the operator cancels the warning message. Severe co nditions includes a flashing red light.
Page 9 Faria ® Serial Bus Installation and Wiring Guide The system consists of: • One Gateway box to interface with the engine and external senders and sensors.
Page 10 T able1 Connector Contacts Pin Pin Function Wir e Color *5 amp Fuse Recommended P1 2 Not used P2 4 1 Battery Positive (always on)* Red 2 Ground 3 Switched Power from Ignition Purple switch cir.
Page 11 Faria Serial Bus Gateway T ypical Power Connections T ypical Instrument Connections P15 P13 P14 P12 P1 1 P7 P8 P10 P6 P5 P4 P1 P3 P15 P13 P14 P12 P1 1 P7 P8 P10 P6 P5 P4 P1 P3 P2 Note: T o help reduce moisture in the gauges be sure to install plug PJ0018 in all open connectors.
Page 12 P15 P13 P12 P7 P8 P10 P6 P5 P4 P1 P3 P2 White White Dk. Blue Nav . Light Switch Instrument Backlight Control P 1 1 6 5 4 3 2 1 7 8 9 10 1 1 12 P 12 6 5 4 3 2 1 7 8 9 10 1 1 12 Faria Serial Bus Gateway Miscellaneous Connections Pink Lt. Blue Oil Pressur e Sender Fuel T a nk Sender P 14 1 2 3 6 5 4 T rans.
Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the company . Faria ® is the trademark of the Thomas G.
Een belangrijk punt na aankoop van elk apparaat Faria Instruments GW0016 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Faria Instruments GW0016 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Faria Instruments GW0016 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Faria Instruments GW0016 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Faria Instruments GW0016 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Faria Instruments GW0016 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Faria Instruments GW0016 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Faria Instruments GW0016 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.