Gebruiksaanwijzing /service van het product UV-18HPC van de fabrikant Field Controls
Ga naar pagina of 12
UV-AIRE™ AIR PURIFYING SYSTEM Mode l: UV-12C,18C,28C, 28,12HP,18HP,28HP,12H PC,18HPC,28HPC READ THESE INSTRUCTIONS CAREFULLY AND COMPLETE LY BEFORE PROCEEDING WITH THE INSTALLATION LEAVE THE INSTALLATION INSTRUCTIONS WITH THE OWNER/OPERATOR OF THE DEVICE AFTER OPENING THE CARTON, UNPACK AND INSPECT THE UNIT AND LAMP FOR DAMAGE.
Page 2 I. INDICATION FOR USE This product is not sold as a medical device and is not for the purpose of diagnosis of any disease or co ndition nor for use in the mitigation, treatment, or pr evention of any disease or condition. II. GENERAL INFORMATION There are different size units avail able, depending on t he squ are footage of your home.
Page 3 III. INSTALLATION 1. Locate a suitable location for the unit downstream from t he ‘A’ coil in the supply plenum or in the return plenum; preferably downstream from the air filter. For optimum “clea n ing” effect on the ‘A’ coil, mount the unit in the supply plenum as close as possible to the ‘A’ coil.
Page 4 2. Determine the type of duct you have. (For flex duct applications, refer to Figure 26 on page 11) I F YOU HAVE METAL DUCT : a. Apply supplied wet and stick mounting template to air d uct in either a vertical or horizontal position as shown in Figure 2.
Page 5 3. Remove base unit and cover from box. 4. Apply supplied “Duct Se al Kit” according to instructions included in kit. (See Figure 12) 5. Determine whether to use flat or angled bracket. (Refe r to “Bulb Mounting Bracket Selection” in Section VI for aid in this decision ) a.
Page 6 8. Insert lamp t hrough the hole until lam p cannot be inserted any further. (See Figure 16) 9. Swing the swivel bracket over the end of lamp. Hand-tighten the wing nut o n the stud. Be careful no to over tighten the wing nut. The po rcelain at the lamp base may crack when over tightened.
Page 7 13. Close the cover and tighten co ver screw. (See Figure 21) 14. Plug the power cord into a standard electrical outlet. NOTE: Seal the joints an d seams of the plenum near the mounting location to reduce any direct viewing of light. (See Figure 1) 15.
Page 8 V. ALARM CIRCUIT WIRING The UV Aire units supplied with a circuit board allo ws for the wi ring of the UV Aire unit into an alarm or security system to monitor the operation of the UV lamp. This circuit is a set of normal open conta cts that close if the operational time exceeds 90 00 hrs or if th e lamp burns out.
Page 9 Chart A VI. BULB MOUNTING BRACKET SELECTION The UV-AIRE TM units come with an a ngled mounting bracket and flat mount ing bracket to position the bul b either straight or at an angle. Cho ose one or the other br acket method be st suited for your needs.
Page 10 VII. MAINTENANCE 1. Inspect and clean lamp at least every 6 months. 2. Replace your UV-Aire™ Ai r Purifying System lamp once a year to maintain the lamps maximum output intensity. The lamp should operate continuously fo r maximum lamp life and light effectiveness.
Page 11 IX. TROUBLESHOOTING GUIDE 1. If the LED is illuminating a “YELLOW” color a nd the ci rcuit board alarm beeps every 15 minutes, the lamp shoul d be replaced soon. 2. If the LED is illuminating a “RED” col or and the circui t board ala rm beeps every 5 minutes, the lamp sho uld be replaced immediately.
Page 12 WARRANTY INFORMATION The health aspects associa ted with the use of these products and t heir ability to aid in di sinfecting of environmental air have not been investigated b y UL. P/N 46453400 Rev E 10/05 Limited Warranty Field Controls, L.
Een belangrijk punt na aankoop van elk apparaat Field Controls UV-18HPC (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Field Controls UV-18HPC heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Field Controls UV-18HPC vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Field Controls UV-18HPC leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Field Controls UV-18HPC krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Field Controls UV-18HPC bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Field Controls UV-18HPC kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Field Controls UV-18HPC . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.