Gebruiksaanwijzing /service van het product FA148CP van de fabrikant First Alert
Ga naar pagina of 16
3URJUDPPLQJ*XLGH ON OFF AR M E D R E A D Y A B C D 6 4 7 9 # 3 5 8 0 2 1 FA260 R A R M E D R E A D Y FA560 6 4 7 9 # 3 5 8 0 2 1 R AWAY STA Y P A G E K5305-5PRV2 10/03 Rev.
– 2 – TO ENTER PROGRAMMING MODE: Local programming requires the use of an alpha keypad connected to the keypad term inals on the control. A. PO WER UP, then depress [ ✱ ] and [#] both at once, within 50 seconds of powering up (if ✱ 98 was used to exit program mode, this method m ust be used to reenter program mode).
– 3 – 352*5$00,1*)250 Entries apply to both the FA168CPS and FA148CP controls, except entries shown in dashed boxes, which apply only to the FA168CPS (partition entries) and are not applicable to the FA148CP . Entry of a number other than one specified will give unpredictable results.
– 4 – NOTE: Entry of a number other than one specifie d will give unpredic table re sults. For fields *43 thr u *46: Enter 0 – 9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; #+15 for F. Enter [ ✱ ] as the fourth digit i f a 3-digit account number (for 3+1 dialer reporting format) is used.
– 5 – ✱ 65 OPEN REPORT CODE [0,0,0] S ee box above. Part. 1 Part. 2 Common ✱ 66 ARM AWAY/STAY RPT CODE [0,0,0 ,0,0,0] See box above. Away Stay Away Stay Away Stay Part. 1 Part. 2 Common ✱ 67 RF XMTR LOW BAT REPORT CODE | [00] See box on previ ous page.
– 6 – ✱ 92 PHONE LINE MONITOR ENABLE UL: see Inst. Instru ctions for req uireme nts [0,0] 1 2 NOTE: Output Device must either be programmed to be STOPPED in fie ld ✱ 80 or STOPPED by Code + # + 8 + output number.
– 7 – MISCELLANEOUS SYSTEM FIELDS (*174-*181) ✱ 174 CLEAN ME REPORTING OPTIONS (for ESL s moke det ectors ) [0] 0 = disabl e; 1 = Clean Me s ignal reports ; Note: If Clean M e is enabled, you must enter “ 3 ” in field ✱ 56 program ming for z one 1 response t ime.
– 8 – Configurable Zone Types Worksheets Configurable zone types 90 and 91 can be programmed v ia downloader software or from a keypad us ing data fields*182-*185. Configurable z one types 92 and 93 (F A168CPS only) c an only be programmed us ing the downloader software.
– 9 – *56 ZONE PROGRAMMING WORKSHEET (FA148CP supports up to 32 zones: 1-6, 9-34, 49-56) [default shown in brackets] Zone Zn Type Part. Report Hardw ire Type Rsp.
– 10 – *57 FUNCTION KEY PROGRAMMING Option Function A B C D Comments 01 Paging 02 Time Disp lay 03 Arm AWAY 04 Arm STAY 05 Arm NIGHT-STAY 06 Step Armi ng 07 Device Activation Device: 08 Comm.
– 11 – ✱ 80 OUTPUT DEFINITIONS Fill in the required data on the worksheet below and follow the programming procedure in the installation m anual as you enter the data during the displays and prompts that appear in sequence. Notes: 1. For Relays, 4229 and 4204 devices are programmed in * 79, *80, and *81 modes.
– 12 – Zone Type Definitions Type 00 Zone Not Used Use this zone ty pe if the z one is not used. Type 01 Entry/Exit Burglary #1 • Assi gn to zones that are us ed for primary entry and ex it. • Provides entry delay if the c ontrol is armed in t he Away or St ay modes .
– 13 – Type 21 Arm-Away • Arms th e system in Aw ay mode w hen the zone is ac tivat ed. • Pushbutton unit s send t he user number t o the cent ral stat ion when arming or dis arming. • User code for butt on must be assigned. Type 22 Disarm • Di sarms th e system w hen the zone is acti vated.
– 14 – ALPHA VOCABULARY LIST (For Entering Zone Descriptors) 000 (Word Space) – A – • 001 AIR • 002 ALARM ∗ 004 A LLEY 005 AMBUSH • 006 AREA • 007 APARTM ENT • 009 ATTIC ∗ 010 A .
– 15 – 5800 Series Transmitter Input Loop Identification All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the inputs requires its own programming zone (e.g., a 5804's four inputs require four programming zones).
CLASS 2 PLUG-IN TRANSFORMER 16.5V AC, 25V A (e.g. 1321). (USE No. 1321CN IN CANADA) TO 110V AC UNSWITCHED OUTLET (24HR) THIS EQUIPMENT SHOULD BE INST ALLED IN ACCORD ANCE WITH THE NA TIONAL FIRE PROTECTION ASSOCIA TION'S ST ANDARD 72, CHAPTER 2 (NA TIONAL FIRE PROTECTION ASSOCIA TION, BA TTERY - MARCH P ARK, QUINCY ,MA 02269).
Een belangrijk punt na aankoop van elk apparaat First Alert FA148CP (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen First Alert FA148CP heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens First Alert FA148CP vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding First Alert FA148CP leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over First Alert FA148CP krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van First Alert FA148CP bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de First Alert FA148CP kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met First Alert FA148CP . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.