Model #647376 T W I N T A N K A I R C O M P R E S S O R 5 Gallon / 3 Peak HP 226892 If you encounter any problems or dif ficulties, Do not return your compressor to the stor e! Please contact our toll-free customer service department at: 1-800-423-3598 • 1-310-522-9008 (Califor nia Only) • www .
It is the owner and/or operator’ s responsibility to study all WARNINGS, operating, and maintenance instructions contained on the product label and instruction manual prior to operation of this unit. The owner/operator shall r etain product instructions for future refer ence.
Duty Cycle: This air compressor pump is capable of running continuously . However , in order to prolong the life of your air compressor , it is recommended that a 50% to 75% average duty cycle be maintained. Duty cycle r efers to the per centage of time a compressor can safely run within a given amount of time expr essed as a ratio.
INTRODUCTION This oil lubricated air compressor is designed for Household Use Only and is not intended for commer cial applications. It is well suited for do-it- yourselfers with a variety of automotive and home uses. This instruction manual is intended for your benefit.
SAFETY WARNINGS READ ALL SAFETY W ARNINGS BEFORE USING AIR COMPRESSOR. GENERAL SAFETY WARNINGS: • Keep work area clean. Messy areas and cluttered workbenches invite personal injury and/or property damage. • Keep children and visitors away . All childr en should be kept away fr om the work ar ea.
DRAIN LIQUID FROM AIR T ANK DAIL Y • Use the drain valve located on the bottom of the lower air tank to drain. Failur e to properly drain liquid from the tank will cause rust from moisture buildup, which weakens the tank and could lead to a violent tank explosion.
RISK OF FALLING Portable air compressors can fall from a table, workbench, or roof causing damage to the compressor and could r esult in serious injury or death to the operator . Always operate air compressor in a stable and secure position to prevent accidental movement of the unit.
IMPROPER INST ALLA TION OF THE GROUNDING PLUG CAN RESUL T IN A RISK OF ELECTRIC SHOCK. IF REP AIR OR REPLACEMENT OF THE CORD IS NECESSARY , DO NOT CONNECT THE GROUNDING WIRE TO EITHER FLA T BLADE TERMINAL. THE WIRE WITH GREEN INSULA TION WITH OR WITHOUT YELLOW STRIPES IS THE GROUNDING WIRE.
7 COMPRESSOR FEA TURES 3 4 5 6 7 8 1 0 1 2 1 3 9 1 1 1 2 1 2.
COMPRESSOR FEA TURES OIL LUBRICA TION: Oil lubricated direct drive pump with cast-iron cylinder for durability . OIL FILL SIGHT GLASS: Located on the face of the crankcase, the oil fill sight glass provides a convenient way to check the oil fill level within the pump.
COMPRESSOR FEA TURES MANUAL THERMAL OVERLOAD SWITCH: The electric motor has a manual thermal overload pr otector . If the motor overheats for any reason, the thermal overload protector will shut off the motor . T urn pressur e switch to the “off” position and wait for unit to cool before pushing the reset button and restarting the compressor .
STEP 2 – INSPECTION CHECK Assembly Check: In order to complete the assembly of your new air compressor , a car eful inspection should be made to ensure that all of the parts are properly aligned and securely fastened. 1. Inspect air filter to ensure that it is installed and secure.
MAINTENANCE DISCONNECT AIR COMPRESSOR FROM POWER SOURCE AND BLEED OFF ALL AIR PRESSURE BEFORE A TTEMPTING ANY MAINTENANCE OR REP AIR. SHUTDOWN AND STORAGE: NOTE: NEVER stop the air compressor by unplugging it fr om the power outlet as this may result in damage to the compressor .
4. Remove oil fill breather plug to allow air to enter crankcase. 5. Remove oil drain plug. 6. Allow oil to drain completely . Tilt air compr essor towards the oil drain to assist draining.
13 TROUBLESHOOTING GUIDE Problem Encountered Possible Cause Possible Solution The compressor does not start or restart: Power cord not plugged in. Plug cord into grounded outlet. Motor/Pressur e switch in OFF position Move switch to AUTO position. Motor thermal overload switch has tripped.
14 TROUBLESHOOTING GUIDE Problem Encountered Possible Cause Possible Solution Air continues to leak at motor/pressur e switch release valve while motor is running: Defective motor/pressure switch. Replace. Check valve stuck in open position. Replace check valve.
P ARTS LIST 15 NO. P ART NO. DESCRIPTION QTY NO. P ART NO. DESCRIPTION QTY 1 647376-1 Bolt 4 55 647376-55 Screw 2 2 647376-2 Spring Washer 4 56 647376-56 Nut 1 3 647376-3 Cylinder Head 1 57 647376-57 .
16 P ARTS DIAGRAM.
ONE YEAR LIMITED W ARRANTY ALL TRADE TOOLS LLC AIR COMPRESSORS Express and Exclusive Limited W arranty to Original Retail Buyer Alltrade T ools LLC (hereinafter “Alltrade”) expressly warrants to t.
Alltrade will not be liable for the following: labor charges, loss or damage resulting from impr oper operation, maintenance or repairs made by other persons; pre-delivery services such as assembly , oil or lubricants, and adjustment; maintenance services that are normally required to maintain the air compr essor .
WEAR SAFETY GLASSES WARNING 1431 V ia Plata Long Beach, CA 90810-1462 USA Made in: China ©2006 REV .1, Alltrade T ools LLC www .alltradetools.com HOT ROD Magazine is a trademark of PRIMEDIA Specialty Group, Inc. and is used with permission. © 2006 PRIMEDIA Specialty Group, Inc.
Een belangrijk punt na aankoop van elk apparaat AllTrade 647376 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen AllTrade 647376 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens AllTrade 647376 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding AllTrade 647376 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over AllTrade 647376 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van AllTrade 647376 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de AllTrade 647376 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met AllTrade 647376 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.