AirPulse ™ Dispenser Oper ating Guide LD S 9 000 AirF ree ™ CA Dispenser.
Thank Y ou for purchasing the Fishman LDS9000 AirF ree TM dispenser . Our 9000-line of AirF ree dispensers uses a patented positive displacement technology to provide the highest level of repeatability of any dispenser utilizing a syringe as a reservoir .
3 P age Getting Started.............................................................................................4 Specifications ...............................................................................................5 Operation ...........
This manual contains all the information you will need to set up and test the 9000 series AirPulse TM dispensers . • Y ou will find the hook up for the LD A V on pages 10-15. F or the MD A V , review 16-19. For the SD A V review 20-23. • Next, pages 24-25 will show your how to set up and test a thick paste-like material.
5 Specifications Input V oltage: 100-240 V A C 47-63 Hz Max Inrush Current: 3.2 A/ 1.8A Output V oltage: 5.0 VDC Output P ower: 4. 6W Fuse Rating: 1.0A/250 V AC Initiate Circuit: F oot P edal (dry contact), finger switch Drive Motor: LDA V 7.5 Degree 48 Steps/Rev MDA V 3.
6 Operation The LDS9000 Dispensing System uses a patented Linear Drive System (LDS) to transfer force from the drive motor to the syringe piston. The motor , lead screw and syringe piston are linked mechanically .
7 Program Contr ol Manual/Auto Dispense • Each mode provides you access to different features on the liquid crystal display . Use the Auto/Manual switch to move back and forth from manual mode to automatic mode . • In manual mode , you can use the foot pedal to dispense a deposit or bead “by eye”.
8 How to use the Control Pad On Screen Instructions When in program mode , if you are not sure what to do wait approximately 3-5 seconds and rolling instructions appear . If you missed them, not to worry , they will repeat until you make an entry . New or Saved Program In Auto Mode hit the NEXT key .
9 How to U se the Control Pad Erase an Input or Make a Selection In Auto mode when entering a new progr am or editing, use the left and right arrow keys to erase and input or skip between choices such as multiple saved progr ams . Use the ENTER key to select a choice .
10 LDS9000 Gun LDS9000 Gun Assembly SureLok™ Retaining Ring Cover Tip Cap Barrel Reservoir PosiLok TM Piston Piston Hub Lead Screw Dispensing Gun.
11 Remove the end cap from the barrel reservoir . • Make sure a tip cap is on the barrel. Remove the retaining ring from the dispense gun. Holding the dispensing gun with the piston hub pointed upward, place the barrel over the piston hub of the dispense gun.
12 Attach the Syringe (continued) Manually twist the barrel in a clockwise direction until the luer lock connector is finger tight and the ears of the barrel are flush against the retaining plate .
13 Removing the Syringe At the end of a dispense program the control unit will display a message: “ Remove syringe and press enter . ” Remove the retaining ring cover by turning clockwise . Slide the retaining ring cover over the barrel reservoir .
14 Program Function Follow These Steps to Input a Program • Press the NEXT key Use the left and right arrow keys to select your syringe size . Enter your dispense volume by using the keypad to enter your volume followed by pressing the ENTER key or use the left or right arrows to use the SpeedBar TM feature*.
SAVE PROGRAM? < - YES NO - > DEFAULT POWER-ON < - YES NO - > 15 Program Function 1 2 To sa ve program, answer YES followed by the program number (0-9) of the location you wish to save your program. If you want the progr am to automatically load as the default program when the machine is turned on, answer YES to the default question.
16 Program Function Follow these steps to save a program to a dif ferent location. • Press the BA CK key to enter the program manager . • Press the NEXT key to enter the Save menu. • Press the left arrow to make the save . • Select a location by pressing a digit from 0-9.
17 How to Make a Bead To dispense a continuous bead of fluid instead of a single dot, follow these steps . Switch the A UTO/MANU AL switch to MANU AL . Set the shot size to the lowest setting . F or best results , set the dispense rate to slow , to minimize backpressure in the syringe .
18 Suggested Tips • The faster you dispense the more backoff you will need. That’s because the speed at which the piston is tra veling exceeds the flow rate of the material out of the dispense tip . Therefore , creating internal pressure . More reverse motion is required to get the internal reservoir pressure back to zero .
19 Operating Tips Components • Always use Fishman AirFree™ barrel reservoirs and dispense tips . Safely dispose after use . This method prevents contamination, ensures proper safety and provides maximum cleanliness . • The heart of the Linear Drive System (LDS) is the AirFree™ piston.
20 Pourable Fluid Tw ist on a tip cap and pour your fluid into the barrel using a funnel. Insert a V enting Ribbon along the inside edge of the barrel, followed by an AirFree™ piston. Carefully press down until it contacts the fluid. While holding the piston in place gently pull the V enting Ribbon from the barrel.
21 Alternative Filling Methods • If your fluid comes prepackaged in a medical style syringe use the Fishman B250001 luer -to luer fitting to transfer the material from prepackaged syringe to the Fishman syringe . • Another option is to use the Fishman C370001 AirPulse TM reservoir filler .
22 Program Mode Program mode is ideally suited for dot type applications or automated (XYZ system) beads . This mode allows you to program a desired volume of fluid for repeated and consistent output. In the program mode there are two utilities . Program Manager and the Sa ve/Restore Manager .
23 Defining the System Drawback: Upon completion of the dispense cycle , fluid oozing out of the dispense tip is a common problem when dispensing compressible fluids . The Dra wback parameter eliminates any oozing by implementing a mechanically reversed action at the end of the dispense cycle .
24 Manual Mode Program is ideally suited for priming the dispense tip and manual dispensing such as potting and beads . In manual mode the parameters and function of the parameters are exactly the same as progr am mode . The only difference is that the system will only dispense fluid for the amount of time the user holds the foot pedal down.
25 Defining the System Retaining Ring— The brawn of the AirF ree dispensing technology The multi-legged stainless steel design locks the syringe in place , making the syringe and gun one .
26 With the power ON, here’ s what happens when you press the foot pedal: The program is engaged, the motor is energized beginning the dispense cycle countdown. The motor pushes the lead screw , with piston attached to the end, down the barrel pushing the liquid out the dispensing tip .
27 Tr oubleshooting Problem: The fluid continues to ooze long after the dispense, (including drawback) is completed. Po t e n tial Solutions: •Check the needle size . The unpredictable nature of the pneumatic drive system has forced customers to use the needle as a flow control.
28 Glossary FOO T .................................Setting for using a foot pedal to activ ate dispensing cycle HAND ................................Setting for using finger switch to activate a dispense cycle SYR .....................................
29 Glossary DISPENSE RA TE ...............Alw ays start with the slowest recommended rate and increase incrementally . DRA WB ACK DELA Y .........When using a small needle you can take advantage of the dra wback delay feature to give you more control over your output volume .
30 Dispenser Component Selector Guide P osiLok TM Flexible Dispense Tips Soft polypropylene burr and flash free tips assure accurate deposit control. Gauge ID .5” 1.5” Color 15G .049” Z532115 Z534115 Brown 18G .032” Z532118 Z534118 Dk. Green 20G .
31 T wo Y ear Fault-Free W arranty Fishman Corporation (Fishman) w arrants its product to be free from defects in materials and workmanship for a period of two years from the date of purchase . Under this warr anty , Fishman will repair or replace any defective part or , at its own option, the complete dispenser regardless of fault.
Fishman Corporation 192 South Street Hopkinton, MA 01748 800-433-2115 Fax 508-435-2119 www .fishmancorp .com email: fishman@fishmancorp .com 2 7 0 26 4.
Een belangrijk punt na aankoop van elk apparaat Fishman LDS9000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Fishman LDS9000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Fishman LDS9000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Fishman LDS9000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Fishman LDS9000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Fishman LDS9000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Fishman LDS9000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Fishman LDS9000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.