Gebruiksaanwijzing /service van het product 11255 van de fabrikant Flanders
Ga naar pagina of 136
the filter and hvac store.
PRODUCT CA T ALOG AMKT0103a Supersedes all previous catalogs. For f ast, efficient ser vice, contact us today at 1-800-347-2220 and look for us on the internet at www .
Dear Customer , As a global leader in the production of high quality air filtration prod- ucts, Flanders Corporation continues to develop new innovations in design, new methods of manufacturing and a .
Disposable Air Filters The widest selection of disposable panels you will find anywhere. Spun glass and synthetic media...all stan- dard sizes and almost any “special” size. Polyester Panels, Links, Sleeves High grade polyester synthetic fiber media in a variety of styles, heat sealed onto heavy wire frames.
Medium & High Efficiency Extended Surface T ype Filters Huge line of “bag” filters in all of the most popular sizes and efficiencies, plus our new XDH bag which holds up to twice as much dust as ordinary bags. Metal W ashable Filters Rugged metal filters for a variety of applications.
Disposable Air Filters: P age HD Industrial Grade Heavy Duty Box Frame, Spun Glass or Synthetic Media . . . . . . . . . . . . . . . . .8 EZ Flow and EZ Flow II Continuous Filament Spun Glass, Box Frame . . . . . . . . . . . . . . . . . . . . . . .10 Pinch Frame Framed Polyester Media with Metal on One Side .
7 HEP A and 95DOP Filters Alpha 95 95% DOP Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79 Alpha Cell HEP A Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 HD Industrial Grade Heavy Duty Disposable P anel Filters Spun Glass Media - Model 10255.xxxxxx Synthetic Media - Model 11255.xxxxxx Grille Sizes - Model 10355.xxxxx General Flanders HD Industrial Grade filters are designed for use in any application where disposable panel filters are recommended.
9 Standard Sizes Performance Data - HD Industrial Grade T ypical initial (clean) pressure drop at nominal cfm is 0.07 in. w.g. for 1 in. filters and 0.10 in. w.g. for 2 in. filters. Recommended final resistance is 0.50 in. w .g., but the system design may dictate a lower change out point.
10 EZ Flow and EZ Flow II Disposable P anel Air Filters EZ Flow - Model 10155.xxxxxx EZFlow II - Model 10055.xxxxxx General EZ Flow and EZ Flow II disposable filters are designed for protection of furnace and central air units in residential and light commercial applica- tions.
Nominal Size (inch) Actual Size H x W x D (in) cfm @ 300 fpm Standard Carton Qty . W eight per Carton (lbs.) 10x10x1 9-7/8 x 9-7/8 x 3/4 208 12 3.3 10x20x1 9-7/8 x 19-7/8 x 3/4 417 12 5.6 10x24x1 9-7/8 x 23-7/8 x 3/4 500 12 6.1 10x25x1 9-7/8 x 24-7/8 x 3/4 521 12 6.
12 Pinch Frame Disposable P anel Air Filters Model 11655.xxxxxx General The Flanders Pinch Frame disposable air filter pro- vides the user with a product of high quality and strength. Originally designed for light commercial and indus- trial applications, the Flanders Pinch Frame filter is an excellent choice for use in residential furnace systems.
13 Nominal Size (inch) Actual Size H x W x D (inches) cfm @ 300 fpm Standard Carton Qty . W eight per Carton (lbs.) 10x20x1 9-7/8 x 19-7/8 x 7/8 420 12 4.0 10x24x1 9-7/8 x 23-7/8 x 7/8 500 12 5.0 10x30x1 9-7/8 x 29-7/8 x 7/8 620 12 5.5 12x20x1 1 1 -7/8 x 19-7/8 x 7/8 500 12 4.
Rugged, Heat-sealed,Construction Flanders Ring Panel and Cube filters are made by heat sealing layers of syn- thetic filtering media together over an interior , corrosion-resistant steel support frame.
15 Series ST55-P olyester P anel Models ST55R-xxxx Ring Panel and ST55L-xxxx Link T wo-ply 1” nominal media construction using a 1/2” nominal white poly- ester on the upstream, followed by a 1/2” nominal green super tackified polyester downstream.
16 Paintbooth Filtration Downdraft Prep Station Crossdraft Flanders offers a wide variety of filtration products for downdraft and crossdraft paintbooths and prep sta- tions.
17 SA600-G10 Diffusion Media for Air Intake Models SA600-xxx For downdrafts and prep stations. This filter pro- vides the highest level of protection against paint damaging particles available today .
18 Series ST55 P anel for Air Intake Models ST55R-xxxx and ST55L-xxxx-xx The SERIES ST55 P ANEL, made in the USA, is an economical choice for crossdraft booths. The SERIES ST55 is made from two media pads. A metal support is dielectrically heat sealed in between the two media layers, providing support and rigidity .
19 Series 331Y P A Models 331Y -xxx 22 gram Fiberglass Paint Arrestor for use in all booth types. Series 331Y is a high quality fiberglass media. Made with 22 grams of fiberglass per square foot, the Series 331Y is more efficient and holds more paint than many other fiberglass prod- ucts.
20 Flanders - Foremost in Air Filtration Corporate Headquarters, St. Petersburg, FL 325T , which is 98% efficient, and the Series 425T which is 99% efficient.
21 port. The media overlaps the support, which pro- vides a gasketing effect reducing air bypass around the filter . A tackifier is applied in between the last two layers to stabilize any migrating particles and prevent the discharge of particles from the filter .
22 The filter media consists of 100% high bulk poly- ester fibers that are thermo-bonded with a fire retar- dant res” Support grilles of expanded metal are provided on both sides of the filter . The media pads and support grilles are continuously glued to the inside perimeter of the frame, resulting in excep- tional strength and rigidity .
23 PS125-Bag Models125BAG-xxxxxx Scrim-Back polyester media bags as prefilter . PS125 Bags are made from a single denier poly- ester media that contains a scrim backing for extra rigidity . The PS125 Bags each contain a metal wire support and a 1” channel frame for easy placement.
24 FP319A T wo-stage and Three-stage P aint Systems Pa intbooth Filtration P ads: FP319AxxxxP AD, Ring P anels: FP319A2020PRK, Cubes: FP319Axxxx , Bags: FP319Axxxxxxxx FP319A Chromate Recover y System.
25 1 2 3 Avg 1 2 3 Avg 1 2 3 Avg 3. Courtaulds yellow fuel tank coating (A) 513X390 base + (B) 910X624 activator - With a conventional air gun operating at 45 psi, with spray feed rate of 105 gr/min @ 120 fpm, initial pressure drop was .23” w .g. Running to final pressure drop at .
26 Service Rolls Flanders Service Rolls air filtration media are man- ufactured in selected widths, prepared in roll lengths that make manageable roll sizes.
T ypically , these are for Lennox type furnaces. ( Lennox is a brand name. It is used here for system identification only .) Hammock rolls are 20 foot rolls of media cut in various widths. In most cases, a sin- gle cut across the roll will produce a ready-to-use filter pad.
28 Wide selection of media types Flanders offers a wide range of top quality air filtra- tion media available in bulk rolls and pads. Considering the unique characteristics of each offering, the user can get maximum value for filter dollar spent with relation to the intended use.
29 Flanders - Foremost in Air Filtration Corporate Headquarters, St. Petersburg, FL the filter and hvac store.
30 Auto Rolls Automatic Roll Filter Replacement Flanders automatic roll replacements are furnished wound on spools or cores, ready for installation without modifica- tion or adaptors. A core selection guide is printed on the back of this sheet. Six-foot-long kraft paper leaders and trailers are secured to the ends of every roll.
31 Flanders - Foremost in Air Filtration Corporate Headquarters, St. Petersburg, FL the filter and hvac store.
32 Important F eatures • Media maximizing v-pleat design • Expanded metal grid prevents media flutter while in operation • Diagonal and horizontal support members pro- vide frame strength • Fi.
33 Expanded Metal Pleat Backing V -Pleat Design Double W all Construction 2-piece die-cut frame Diagonal grid supports for maximum strength Efficient High-Loft Media Principles of Operation Flanders’ v-pleat design insures that the greatest media area is exposed to the air flow to promote uniform dust loading.
34 Capacities and Dimensions Notes: 1. PD represents clean pressure drop in inches w .g. The recommended final pressure drop for all models is 1.0 in. w .g. System design may dictate a lower change-out point. 2. Actual filter face size for 12 x 24 and 24 x 24 filters is 5/8 in.
35 1.0 General 1.1 Medium efficiency filters shall be Pre Pleat 40 extended surface pleated filters as manufactured by Flanders.. 1.2 Filter sizes and capacities shall be as scheduled on the drawings. 1.3 Filters shall be UL 900 Class 1 or 2 listed. 2.
36 Pre Pleat HV High V elocity and Gas T urbine Pleat Models 85455.xxxxxx General The Pre Pleat HV pleated filter from Flanders is designed to operate in high velocity and turbulent air applications where standard pleated filters have a tendency to fail.
Depth Nominal Depth (inch) 10 x 10 x 1 210 0.15 347 0.38 1.6 10 x 20 x 1 417 0.15 694 0.38 3.2 12 x 20 x 1 500 0.15 833 0.38 3.8 12 x 24 x 1 600 0.15 1000 0.38 4.5 14 x 20 x 1 583 0.15 972 0.38 4.5 14 x 25 x 1 729 0.15 1215 0.38 5.3 15 x 20 x 1 625 0.
38 Pre Pleat 62R High Efficiency Pleated Filters Standard Capacity: 85655.xxxxxx High Capacity: 85755.xxxxxx Important F eatures • MERV 8 per ASHRAE Standard 52.
re Pleat 62RM1 1 pleated panel filter enables a significant upgrade in collection efficiency over existing MERV 8 products at the same resistance levels. From 30-35% to 60-65% average per Ashrae 52.1-1992 average dust spot efficiency at nearly the same pricing levels.
40 1.0 General 1.1 Air filters shall be Model Pre Pleat 62RM1 1 panel filers, as manufactured by Flanders. 2.0 Filter Construction 2.1 Eac h fi lte r s hall consist of an electrostatically charged synthetic only media, with corrosion- resistant expanded metal backing and moisture resistant enclosing frame.
41 Pre Pleat Class 1 UL 900 Class 1 Pleated Filter Standard Capacity: 85855.xxxxxx High Capacity: 85955.xxxxxx Important F eatures • UL 900 Class 1 for flammability • Easily disposable • Offered.
42 1.0 General 1.1 Medium efficiency UL Class 1 fire rated pleated filters shall be Pre Pleat Class 1 as manufactured by Flanders. 1.2 Filter sizes and capacities shall be scheduled on the drawings.
43 Pre Pleat HT High T emperature Pleated Filters Standard Capacity: 84555.xxxxxx High Capacity: 84655.xxxxxx Up to 400 o F Flanders Pre Pleat HT filters are designed for increased air filtration effi.
44 1.0 General 1.1 High T emperature pleated filters shall be Pre Pleat HT as manufactured by Flanders. 1.2 Filter sizes and capacities shall be scheduled on the drawings. 1.3 Filters shall be UL Class 1 listed and be able to operate up to 400 degrees Fahrenheit.
45 E35 Pleated P anel Filters Models E35-xxxxx General Flanders E35 extended surface pleated filters are designed to operate in most installations. Available in 1”, 2”, and 4” nominal thickness, these filters have an average atmospheric dust spot efficiency range of 25-30% per ASHRAE Standard 52.
46 1 2 4 E35-10201 E35-12201 E35-12241 E35-14201 E35-14251 E35-15201 E35-16201 E35-16251 E35-18241 E35-18251 E35-20201 E35-20241 E35-20251 E35-24241 E35-10202 E35-12202 E35-12242 E35-14202 E35-14252 E.
47 Flanders - Foremost in Air Filtration Corporate Headquarters, St. Petersburg, FL General Superflow-V extended surface area low pressure drop minipleat filters are designed for use in most commercial and industrial HV AC systems where medium to high efficiency filtration is required.
48 Flanders - Foremost in Air Filtration Corporate Headquarters, St. Petersburg, FL Nominal Size 250 FPM 375 FPM 5 00 FPM 625 FPM 750 FPM Media Wt. Efficiency Model HxWxD Area Each % Number Inches (Sq.Ft) (Lbs.) CFM PD CFM PD CFM PD CFM PD CFM PD Guide Specifications P erformance Data Notes: 1.
49 General Rigid-Air extended media surface rigid filters are designed for use in most commercial or industrial HV AC systems where medium to high ef ficiency fil- tration is required. They feature your selection of media backed with expanded metal and pleated.
50 Notes: 1. PD represents clean pressure drop in inches w .g. Recommended final pressure drop for all models is 1.5 inches w .g. 2. Operation down to zero airflow is satisfactory for all models. 3. Consult factory before operating at these velocities.
51 Notes: 1. PD represents clean pressure drop in inches w .g. Recommended final pressure drop for all models is 1.5 inches w .g. 2. Operation down to zero airflow is satisfactory for all models. 3. Consult factory before operating at these velocities.
52 Application Guidelines Rigid-Air filters may be used wherever job require- ments and available space will accommodate 6” or 12” deep filters. Rigid-Air filters should be selected using 24” x 24” and 24” x 12” face sizes.
53 General PrecisionCell extended media separator type rigid filters are designed for use in most commercial or industrial HV AC systems where medium to high ef fi- ciency filtration is required. PrecisionCell filters are available in average efficiency ranges of 60-65%, 80-85% and 90-95% per ASHRAE Standard 52.
54 12 6 25 x 20 x 12 25 x 16 x 12 24 x 20 x 12 24 x 18 x 12 20 x 20 x 12 20 x 16 x 12 25 x 20 x 6 25 x 16 x 6 24 x 20 x 6 24 x 18 x 6 20 x 20 x 6 20 x 16 x 6 1750 1400 1700 1600 1400 1 100 875 700 850.
55 PrecisionCell Single Header filters are rec- ommended for through-the-frame applica- tions. Install by loading the filters through the T ype 9 frame until the header comes into contact with the gasket on the frame. Secure in place with Model P fasteners.
56 Application Guidelines PrecisionCell filters may be used wherever job requirements dictate totally rigid filters and available space will allow only minimal inline depth. PrecisionCell filters should be selected using 24” x 24” and 24” x 12” face sizes.
57 57 PrecisionCell HT High T emperature Rigid Filters ASHRAE 65% 86255.xxxxxxH ASHRAE 85% 88255.xxxxxx ASHRAE 95% 89255.xxxxxxH General PrecisionCell HT filters are designed for high tem- perature applications up to 900 o F. They featur e th e same rugged construction as the standard PrecisionCell.
58 Operating Nominal Size 500 fpm Media Weight Efficiency Limit o FH x W x D (inch) Rating Area Each cfm pd (sq. ft.) (lbs) 750 24 x 24 x 12 2000 .35 140 26 60-65% 24 x 12 x 12 1000 69 21 900 24 x 24 x 12 2000 .30 175 28 24 x 12 x 12 1000 90 22 750 24 x 24 x 12 2000 .
59 59 PrecisionCell GT Gas T urbine Rigid Filters ASHRAE 65%z: PGT65xxxxxxxH ASHRAE 95%: PGT95xxxxxxxH General The PrecisionCell GT features heavy-duty con- struction to meet the rigorous demands of gas tur- bine rotary machinery air filtration applications.
60 60 Nominal Nominal 250 fpm 375 fpm 500 fpm 625 fpm Media Weight Depth Efficiency Size Area Each (inch) HxWxD cfm pd cfm pd cfm pd cfm pd (sq.ft.) (lbs.) (inch) 24x24x12 1000 1500 2000 2500 140 26 12 65% .15 .25 .35 .40 24x12x12 500 750 1000 1250 69 21 24x24x12 1000 1500 2000 2500 140 30 12 95% .
61 General PrecisionCell II extended surface minipleat rigid fil- ters are a nominal four inches deep. They are designed for use in most commercial and industrial HV AC systems where medium to high ef ficiency fil- tration is required. They are available in average efficiency ranges of 60-65%, 80-85% and 90-95% per ASHRAE Standard 52.
62 Construction In the Flanders tradition of state-of-the-art technology , PrecisionCell II filters are built with a minipleat media pack to achieve a rugged, compact lightweight, high efficiency filter .
63 Prefilters Prefilters are always a wise choice for the protec- tion of minipleat filters no matter what the efficiency or brand. The closely-spaced pleats are subject to face-loading (bridging) by lint and coarse particles, thus reducing their usual long life.
64 Notes 1. PD represents clean pressure drop in inches w .g. Recommended final pressure drop for all models is 1.5 inch w .g. 2. Operation down to zero air flow is satisfactory for all models. 3.Actual filter face size of 24” x 24” and 24” x 12” is 5/8” undercut on height and width.
65 Important F eatures • Fully interchangeable with other manufac- turers’ hardware. • Heavy-duty fiberboard side panels. • Filters are UL 900 Class 2 listed.
66 Cfm Capacity Pressure Drop (inch w .g.) Efficiency % Model Number Actual HxWxD (inch) 1.0 General 1.1 Filters shall be Model EA Series replacement fil- ters as manufactured by Flanders. 1.2 Filters shall be UL 900 Class 2 listed. 2.0 Filter Construction 2.
67 General Precision Pak extended surface bag filters are designed for use in most commercial or industrial HV AC systems where medium to high ef ficiency fil- tration is required.
68 Performance values stated may be averages typical of the products listed. Contact factory for actual performance test reports on specific products. How to Select a Precision Pak Filter • Determine the ASHRAE efficiency desired.
1500 750 1500 750 1500 750 1500 750 1500 750 1500 750 1500 750 1500 750 1500 750 0.18 0.18 0.19 0.19 0.16 0.16 0.15 0.15 0.18 0.18 0.15 0.15 0.14 0.14 0.18 0.18 0.14 0.14 2000 1000 2000 1000 2000 1000 2000 1000 2000 1000 2000 1000 2000 1000 2000 1000 2000 1000 0.
70 Guide Specifications Application Guidelines Precision Pak filters should be selected using 24” x 12” face sizes. This allows for 12” increments in height and width of the filter bank and insures that replacement filters will be readily available.
71 Important Features • INTREPIDTM by Kimberly-Clark • Extra high dust holding capacity • Dual stage gradient density electrostatic media • Low initial pressure drop provides long life •W id.
72 Nom. Width (inch) Nom. Height (inch) 85% XDH Synthetic Media Filters Nominal Depth (inch) Number of Pockets 24 12 24 12 24 12 24 12 24 12 24 12 24 12 24 12 24 12 24 12 24 24 24 24 24 24 24 24 24 24.
73 75% XDH Synthetic Media Filters Nominal Depth (inch) Number of Pockets Nom. Width (inch) Nom Height (inch) 24 12 24 12 24 12 24 12 24 12 24 12 24 12 24 12 24 12 24 12 24 24 24 24 24 24 24 24 24 24 .
74 Application Guidelines Precision Pak XDH filters should be selected using 24” x 12” and 24” x 24” face sizes. This allows for 12” increments in height and width of the filter bank and insures that replacement filters will be readily available.
75 General Flanders models MS and MSG Moisture Separators are designed for use in air handling sys- tems requiring collection of water droplets or oil mist.
76 Guide Specifications Construction Moisture separators are constructed much like permanent metal washable filters. The nominal two inch thick media pack consists of 15 individual layers of pleated and flat aluminum wire mesh. Air entering and exiting support grids are expanded metal, and the media enclosing frame is 16 ga.
77 General Flanders Model KKM is a heavy duty , washable, aluminum media, all metal filter . KKM is suitable for all residential and commercial applications. The KKM offers large filtering area, high dust hold- ing capacity , uniform loading and low resistance to air flow .
78 1.0 General 1.1 W ashable air filters shall be KKM Air Filters as supplied by Flanders. 2.0 Filter Construction 2.1 Frame shall be galvanized steel with mitered corners and secured with pop rivet(s). Frame shall have drain holes in three corners. 2.
79 General Flanders Alpha 95 Filters are designed for use in HV AC applications requiring cleaner air than is pos- sible with ASHRAE - rated filters, but where HEP A - filtered air is not required. The filters are rated at 95% efficiency on 0.30 micrometer particles by the DOP test method.
80 Construction Flanders manufactures both conventional Separator Style and Pureform Separatorless 95 DOP Filters. T o make a Separator Style filter , the media is folded over corrugated aluminum separators with hemmed edges to separate the pleats in the filter pack.
81 Frame Materials Alpha 95 Filters are available in a variety of wood and metal frame materials such as particle board, plywood, galvanized steel and stainless steel. Gasket and Fluid Seal The standard gasket seal is 0.75” x 0.25” neoprene for installation on either the upstream, downstream or both sides of the filter .
82 Guide Specifications 1.0 General 1.1 Alpha 95 filters shall be extended media (sepa- rator type) (Pureform separatorless type) filters as manufactured by Flanders. 1.2 Filter sizes, capacities and construction options shall be as scheduled on the drawings.
83 Flanders - Foremost in Air Filtration Corporate Headquarters, St. Petersburg, FL General Flanders offers a complete line of Alpha Cell HEP A Filters in two efficiencies to meet the needs of criti- cal applications where HEP A filtration is required.
84 Flanders manufactures both conventional Separator Style and Pureform Separatorless HEP A Filters. T o make a Separator Style filter , the media is folded over corrugated aluminum separators with hemmed edges to separate the pleats in the filter pack.
85 Frame Materials AlphaCell Filters are available in a variety of wood and metal frame materials such as particle board, ply- wood, galvanized steel and stainless steel. Gasket and Fluid Seal The standard gasket seal is 0.75” x 0.25” neoprene for installation on either the upstream, downstream or both sides of the filter .
86 1.0 General 1.1 Alpha Cell HEP A filters shall be extended media (separator type) (Pureform separatorless type) fil- ters as manufactured by Flanders. 1.2 Filter sizes, capacities and construction options shall be as scheduled on the drawings. 1.3 Filters shall be (UL 900 Class 1)( UL 900 Class 2) listed.
87 High Capacity Design The Alpha 2000 High Capacity HEP A filter is avail- able in a nominal 12” depth configuration. It is designed for optimum performance and low operat- ing costs in both new and replacement systems.
88 Alpha 2000 HEP A Filter Dimensions and Capacities Filter Depth Filter Size and Frame Actual Face Size CFM Capacity at Clean Weight (inches) Depth Designator (Inches Pressure Drop, Inches w .
89 Frame Materials Alpha 2000 Filters are available in a variety of wood and metal frame materials such as particle board, ply- wood, galvanized steel and stainless steel. Gasket and Fluid Seal The standard gasket seal is 0.75” x 0.25” neoprene for installation on either the upstream, downstream or both sides of the filter .
90 1.0General 1.1 Alpha Cell HEP A filters shall be extended media (separator type) (Pureform separatorless type) filters as manufactured by Flanders. 1.2 Filter sizes, capacities and construction options shall be as scheduled on the drawings. 1.3 Filters shall be (UL 900 Class 1)( UL 900 Class 2) listed.
91 General Flanders manufactures metal-frame separator-style HEP A filters for applications with high-temperature requirements up to 1,000°F (540°C) for exhaust air only and 500°F (260°C) for supply air . High-tem- perature filters are available with either a gasket or fluid seal.
92 Guide Specifications 1.0 General 1.1 High temperature separator style HEP A filters shall be Alpha HT models as manufactured by Flanders. 1.2 Filter sizes, capacities and construction options shall be as scheduled on the drawings. 2.0 Filter Construction 2.
93 General Flanders Superflow 2K is a V -bed HEP A filter (99.99% at 0.30 micrometer) specifically designed for high airflow applications requiring HEP A effi- ciency at an ultra low pressure drop. The Superflow 2K can be incorporated into systems with air veloc- ities of 500 fpm and a pressure drop of 1.
94 Model Number Nominal Size Actual Size Media Area Rated Flow SF2K-(*)-G(location)-GG 24" x 24" x 12" 24" x 24" x 1 1-1/2" 290 sq. ft. 2000 cfm SF2K-(*)-G(location)-CG 12" x 24" x 12" 12" x 24" x 1 1-1/2" 140 sq.
95 General Alpha Panel Minipleat HEP A/ULP A filters are avail- able in two particle size efficiencies: 99.99% on 0.3 µm and 99.99% on 0.12 µm. They are of fered in a complete range of standard sizes to meet the needs of critical applications where HEP A/ULP A filtration is required.
Flanders - Foremost in Air Filtration Corporate Headquarters, St. Petersburg, FL 96 Guide Specifications 1.0 General 1.1 Minipleat HEP A/ULP A filters shall be Alpha Panel Model AP493 or AP591 as manufactured by Flanders. 1.2 Filter sizes and capacities shall be as scheduled on the drawings.
97 General Flanders Pureflo T erminal HEP A/ULP A Filter Modules are lightweight low profile ducted units. The mini-pleat filter packs are designed to provide unidirectional airflow from tee-bar ceilings. Pureflo modules are available in two sizes: nominal 24” x 24” and 24” x 48” with either 10” or 12” diameter inlet collars.
Clean Filter Resistance(“w .g) Clean Filter Filter Resistance(inchw .g) 23-5/8 47-5/8 PF†-493-2424-* PF†-493-2448-* PF†-591-2424-* PF†-591-2448-* 23-5/8 47-5/8 Physical Data Notes: 1. *Insert suffix 10 (nominal 10”collar) or 12 (nominal 12” collar).
99 99 Pureflo-FPM F an-P owered T erminal Filter Modules Standard: PF-FPM*-xxxx-STD Room Side: PF-FPM*-xxxx-RSR (Where * is efficiency designator of 493 for 99.99% efficient on .3 micron particles and 591 is 99.9995% efficient on .12 micron partic les.
100 Standard Replaceable Module Room Side Replaceable Module PF-FPM-493-2424-RSR PF-FPM-493-2424-STD 99.99 23.87 23.63 360 1.68 659 0.86 PF-FPM-493-2448-RSR PF-FPM-493-2448-STD 0.3 F m 47.87 47.63 720 2.04 800 0.72 PF-FPM-591-2424-RSR PF-FPM-591-2424-STD 99.
101 FCP Carbon Pleat Activated Carbon Adsorbers Models FCP*xxxxx (Where * indicates carbon type model of 201, 202, 204, 301, 302, 304. See price book.) This table illustrates the differences in overall capacity of three carbon prod- ucts. Capacity to Product 75% Breakthrough Carbon Slurry 1.
102 FCP Selection Media Rated Flow Initial Model Number Nominal Size Actual Size Area (cfm) Resistance (inches) (inches) (sq. ft.) (inch w .g.) FCP201-24242 24 x 24 x 2 23-3/8 x 23-3/8 x 1-3/4 20 2000 .55 FCP201-12242 12 x 24 x 2 1 1-3/8 x 23-3/8 x 1-3/4 10 1000 .
103 Improves IAQ through odor abatement and better particulate air filtration Many strong odors in living spaces come from materials that are either strong acids or strong bases. For example, sauerkraut smells up the house because it is highly acidic.
104 Sensor y testing Body Odor Odor level testing was conducted in jars set up spe- cially for headspace odor testing. Sensory evalua- tion was run 20 hours after the jars had been set up to allow for ade- quate equilibration. 20 panelists participated in headspace odor level testing.
105 Model C Disposable Carbon Gas Phase Odor Control Filters 50% Fill, models: C50-xxxxx 75% fill, models: C75-xxxxxx General The Model C Disposable Carbon air filter is an easy-to-install partial-bypass carbon type air purifi- er for light duty IAQ applications in home and com- mercial recirculated air systems.
106 1.0 General 1.1 Disposable carbon air filters shall be Model C as manufactured by Flanders. 2.0 Filter Construction 2.1 Filters shall be constructed of laminated cellulose paper honeycomb whose cells are partially filled with granular virgin coconut shell base activated carbon.
107 Superflow-VC Disposable Carbon Adsorber Models SFVC*-xxxxxx (Where * indicates carbon type: 201, 202, 204, 205 or 209. See Price book.) F eatures and Benefits •T otal detention multi-panel desig.
Flanders - Foremost in Air Filtration Corporate Headquarters, St. Petersburg, FL 108 Application Considerations Superflow-VC Adsorbers in HV AC airstreams can remove many gaseous contaminants thus mitigat- ing their effects on people and processes.
109 Adsorber Protection Particulate contamination must be considered when utilizing gas/vapor phase adsorbers. As a minimum, a Flanders prefilter with an efficiency of 25-30% per ASHRAE Std. 52.1 should be installed on the upstream side of the Superflow-VC adsorber in order to extend the service life by significantly reducing dirt build-up.
110 110 Adsorber Model Number (See Note 1) SFVC-242412 SFVC-122412 Nominal Size H x W x D mm. (See Note 2) 610 x 610 x 305 305 x 610 x 3 0 5 Adsorber Model Number (See Note 1) SFVC-242412 SFVC-122412 Nominal Size H x W x D inch (See Note 2) 24 x 24 x 12 cfm 500 250 PD 0.
111 V aporclean V apor Phase Air Filter Models VC-xxxx-xx-xx-xxxx-xx See price book Important F eatures • Maximized carbon surface area • Increased efficiency and capacity • Low initial static p.
112 Sample Model Number VC 1501 16 01 2424 GD V aporclean Media type 24 ga Frame Style Size Gasket V aporclean P erformance The pressure drop of the V aporclean is 0.35 inch w .g. at a face velocity of 500 fpm. The initial efficiency of the adsorber under the following conditions shall be met.
Flanders - Foremost in Air Filtration Corporate Headquarters, St. Petersburg, FL 113 General HMZD carbon panels are available from 3/8” to 3” depths, and are easily installed in any existing side or front access housing without the usual clean up caused by carbon dusting.
Flanders - Foremost in Air Filtration Corporate Headquarters, St. Petersburg, FL 114 Pressure Drop HMZD Panels can be incorporated into V shaped configurations with minimal pressure drop and impact on the system. Please note that the breakthrough test was based on continuous 100 ppm Hexane chal- lenge concentration.
Flanders - Foremost in Air Filtration Corporate Headquarters, St. Petersburg, FL 115 Clean Air is Only a Block A way Flanders, through innovative technology , has resolved the problems associated with loose filled activated carbon trays by introducing HMZD bond- ed carbon panels.
116 Guide Specifications 1.0 General 1.1 Molecular contamination control filters shall be Flanders High Mass and Zero Dust (HMZD) bond- ed carbonpanels. Panels shall be self-supported bonded granular carbon and be sized to fit into the selected Flanders Pureseal front or side access housing as well as competitive carbon systems.
117 T echsorb Chemical Media for Gaseous Contaminant Removal Models TS-*-B1 (Where * indicates chemical media designator . See price book.) General Applications T echsorb chemical media is specifically formulated to control application specific nuisance and harmful vapors.
Flanders - Foremost in Air Filtration Corporate Headquarters, St. Petersburg, FL 118 Notes 1. Contaminant removal capacity is determined by passing a moist (85% r .
General Flanders T ype 9 Holding Frames are used to con- struct built-up filter banks for upstream or down- stream access using ASHRAE rated filters. T ype 9 frames will accommodate 1”, 2” or 4” panel filters including metal washable filters.
Flanders - Foremost in Air Filtration Corporate Headquarters, St. Petersburg, FL 120 Fastener Selection Chart Model P Fastener Model C-2 and C-4 Fastener Model C-12 Spring Loaded Fastener Model Length.
121 General Uni-Frames are designed for retaining air filter media pads in applications that require additional media support. The frame is fabricated of 26 gauge corrosion- resistant steel channel with each corner of the frame mitered for squareness.
122 K-T rac Modular Filter Framing System See model number development method on next page. Important F eatures • Provides substantial savings in field assembly • Filters are tightly sealed to eli.
123 Height CodeOverall Height (inch)Width Code Height Overall Face 15W 20W 25W 30W 35W 40W 45W 50W 55W 60W 65W 70W Code Height Velocity Overall Width (inch) (in) (fpm) 36-1/26 48-1/16 59-7/16 71-7/16 82-13/16 94-13/16 106-13/16 118-13/16 129-9/16 141-9/16 152-15/16 164-15/16 10H 24-1/2 375 2250 3000 3750 4500 5250 6000 6750 75 82.
124 How the K-T rac W orks • A= 24” x 24” face size filter . C = 24” x 12” face size filter . • W eight does not include filters. Add approximately 6 lbs. per Precision Pak bag filter , 20 lbs. per PrecisionCell filter , 17 lbs. per Superflow V filter , and 17 lbs.
125 Drawing Notes 1. Framing members of extruded aluminum are factory-cut to exact length, pre-drilled and gasketed. 2. One vertical support for the center of the upstream side will be furnished on modules nominal 8 ft. wide. Wider mod- ules will be furnished with vertical supports on both the upstream and downstream sides.
Flanders - Foremost in Air Filtration Corporate Headquarters, St. Petersburg, FL 126 Perma Frame Hard Ceiling Adaptor Frames for T erminal Modules Models HCF A-xxxx General Flanders Perma Frame is used to mount ducted or fan-powered terminal modules in a hard ceiling application such as sheet rock or plasterboard.
127 Guide Specifications 1.0 General 1.1 Sheet rock adaptor frame for ceiling mounted ter- minal modules shall be Perma Frame as manu- factured by Flanders. 2.0 Frame Construction 2.1 Frames shall be constructed of 18 gauge steel and welded flush on all exposed corners.
128 Residential Air Cleaner Refills For Space Gard ® , Air Bear ® , Honeywell ® Air Cleaners* See model numbers in chart on next page. Media for high efficiency air c leaners For over 50 years, Flanders air filters have been protecting cleanrooms, hospital operating rooms and other critical environments.
129 Efficiency by P article Size Microns Efficiency 0.35 16% 0.62 28% 0.84 38% 1.14 47% 1.88 68% 3.46 75% 4.69 71% 6.20 69% 8.37 66% Replacement for: FP Refill(s) MERV Media Frame FP Model Honeywell ® 203719 203720 203721 203722 See FP Model 8 Electrostatic Poly Blend Wa ter resistant kraft board 82655.
130 Model 500AB Air Cleaner Housing Model 82855.052025 General The Model 500AB air cleaner housing is designed for use with the Model 500AB or 550AB cartridge in an HV AC system. Both of these cartridges feature deep pleated media whose area is several times the face area of the housing.
131 V ersatile Installation The Model 500AB air cleaner housing can be installed in a variety of configurations; Highboy , Lowboy , Horizontal, Upflow or V ertical Downflow . TYPICAL TRANSITION (VERTIC AL DOWNFLOW) LOWBO Y HORIZONT AL HIGHBO Y UPFLOW Flanders - Foremost in Air Filtration Corporate Headquarters, St.
132 Airia 350 Electronic Room Air Cleaner Important F eatures • Super quiet operation • Operates for pennies a day . • 4 stage filtration removes particles, odors. • Moves 350 cubic feet of air every minute. • Built-in casters for easy moving.
133 General The Airia line of electronic air cleaners delivers high, instantaneous filtering efficiency in a reliable, permanent package that is built to last the life of an air handling system. Airflow resistance is low and constant. Operation costs only pennies per day .
134 Specifications Airia 1400 (16x25) Airia 2000 (20x25 Rated Capacity 1400 CFM 2000 CFM Electrical Input 120 V ac, 1 Ph, 60 Hz 120 V ac, 1 Ph, 60 Hz Power Consumption 40 watts 48 watts Resistance to Airflow 0.2” w .g. @ 1400 CFM 0.2” w .g. @ 2000 CFM Unit Weight 40 lbs.
the filter and hvac store.
the filter and hvac store.
Een belangrijk punt na aankoop van elk apparaat Flanders 11255 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Flanders 11255 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Flanders 11255 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Flanders 11255 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Flanders 11255 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Flanders 11255 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Flanders 11255 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Flanders 11255 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.