For more information, visit www .fmiproducts.com SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed.
www .fmiproducts.com 109036-01M 2 SAFETY W ARNING: Do not install a replace insert in this box unless the manufacturer's instructions with the insert specically state this replace has been tested for use with this insert.
www .fmiproducts.com 109036-01M 3 SPECIFICA TIONS 0" TO BOTTOM OUTSIDE AIR (LEFT SIDE ONL Y) TOP SP ACERS 3/4" AIR SP ACE BACK AND SIDES HEARTH EXTENSION 66" X 20" 12" EACH SI.
www .fmiproducts.com 109036-01M 4 FIREPLACE INST ALLA TION SELECTING LOCA TION T o determine safest and most efcient location for replace, you must take into consideration the following guidelines: 1. Location must allow for proper clearances (see Figures 1 and 2).
www .fmiproducts.com 109036-01M 5 HEARTH EXTENSION A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of replace opening is required to protect combustible oor construction in front of replace.
www .fmiproducts.com 109036-01M 6 FIREPLACE INST ALLA TION Continued Figure 4 - Mantel Clearances to Combustible Material Electrical Bushing Electrical Cover Plate Rocker Switch Figure 6 - Fan Switch-.
www .fmiproducts.com 109036-01M 7 Figure 8 - Lineal Gain Hemmed End 8" Stainless Inner Pipe 12 3 / 8 " Galvanized Outer Pipe Figure 7 - Outside Air Kit Secure to Collars with Metal T ape, Screws or Straps (Min.
www .fmiproducts.com 109036-01M 8 VENTING INST ALLA TION Continued Figure 9 - T ypical Offset Installation Return Elbow Offset Elbow Return Elbow Offset Elbow 6' Max.
www .fmiproducts.com 109036-01M 9 Figure 1 1 - Elbow Offset B A Screws Figure 10 - Ceiling Support Pipe 12S-8DM OFFSET RISE CHIMNEY LENGTH A B 48" 36" 24" 18" 12" 4 3 / 8 &quo.
www .fmiproducts.com 109036-01M 10 VENTING INST ALLA TION Continued Pitch Slope Opening "A" Max. Used Flashing Model No. Flat 0° 15" V6F-8DM 0-6/12 26.6° 16 1 / 8 " V6F-8DM 6/12- 12/12 45.0° 20 3 / 8 " V12F-8DM 4. Remove shingles around opening mea - sured.
www .fmiproducts.com 109036-01M 11 Nail Only Outer Perimeter of Flashing Storm Collar Underlap Shingles at Bottom Overlap Shingles T op and Sides Only Figure 15 - Flashing Installation Figure 16 - Sto.
www .fmiproducts.com 109036-01M 12 10' 2' Min. 10' 3' Min. 2' Min. 3' Min. Level of Flue Gas Outlet Figure 19 - 10 Foot Rule 10 FOOT RULE All ue gas outlet chimney ter.
www .fmiproducts.com 109036-01M 13 OPTIONAL GAS LINE INST ALLA TION Figure 21 - Gas Line Knockout Side Firebrick Finished Side Refractory Knockout Plug Outside of Fireplace Gas Line Conduit Insulation Gas Conduit Cover 1/2" Dowel Gas line hook up should be done by your supplier or a qualied service person.
www .fmiproducts.com 109036-01M 14 OPTIONAL GAS LINE INST ALLA TION Continued W ARNING: If the replace has been used for wood burn- ing, rebox and chimney must be cleaned of soot, creosote and ashes be a qualied chimney cleaner . Creosote will ignite if heavily heated.
www .fmiproducts.com 109036-01M 15 Figure 24 - Damper Handle Location OPERA TION AND MAINTENANCE Continued DAMPER HANDLE OPERA TION Damper handle, which opens and closes damper blade, is located inside rebox at center towards back w all (see Figure 24).
www .fmiproducts.com 109036-01M 16 P ARTS WOOD BURNING FIREPLACE MODELS (V)B42, (V)B42I, (V)B42L, (V)B42LI 11 27 30 23 22 24 10 14 25 4 17 3 2 1 5 20 28 12 7 15 9 16 13 8 26 6 29 19 18 21.
www .fmiproducts.com 109036-01M 17 P ARTS WOOD BURNING FIREPLACE MODELS (V)B42, (V)B42I, (V)B42L, (V)B42LI This list contains replaceable parts used in your replace. When ordering parts, see Replace- ment Parts on page 15 of this manual. KEY NO. P ART NO.
www .fmiproducts.com 109036-01M 18 ROOF FLASHING 0 TO 6/12 PITCH - V6F-8DM 6/12 TO 12/12 PITCH - V12F-8DM ACCESSORIES DOUBLE W ALL PIPE 12-8DM 12-8HT 18-8DM 18-8HT 24-8DM 24-8HT 36-8DM 36-8HT 48-8DM 4.
www .fmiproducts.com 109036-01M 19 F AN KIT - BK3 BLOWER KIT - BK OUTSIDE AIR KIT FOR SIDE W ALL INST ALLA TION - AK4 OUTSIDE AIR KIT FOR FLOOR INST ALLA TION AK4F ACCESSORIES Continued SQUARE TOP TER.
109036-01 Rev . M 03/1 1 2701 S. Harbor Blvd. Santa Ana, CA 92704 1-866-328-4537 www .fmipr oducts.com.
Een belangrijk punt na aankoop van elk apparaat FMI (V)B42LI (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen FMI (V)B42LI heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens FMI (V)B42LI vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding FMI (V)B42LI leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over FMI (V)B42LI krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van FMI (V)B42LI bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de FMI (V)B42LI kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met FMI (V)B42LI . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.