Instructions Models MM39/44/49VF Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance. WHA T TO DO IF YOU SMELL GAS: Do not try to light any appliance. • Do not touch any electrical switch; do • not use any phone in your building.
FireplacePartsDiagram......................................................................................... Pg.2 FireplacePartsList................................................................................................
2 Fireplace Parts Diagram Figure 1 Exploded Diagram 5 9 12 2 7 1 3A 2X 2X 3X 7X 2X 8X 3 6 11 W ARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specically approved with this appliance may result in property damage or personal injury .
3 Optional Outside Ø4” Combustion Air Kit Model No.: MM4AK (Ø4” Ducting not included) Refractory Firebrick Liners (HerringbonePatternshown,alsoavailable inRunningBond-seePg.
4 General Information Introduction WeextendawarmwelcomefromallofusatFMI PRODUCTS,LLCproudmanufacturersoftheGrandMeridian Fireplaces.
5 Safety Information Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the u, with headaches, dizziness, or nausea. If you have these signs, the replace may not be working properly .
6 Location Note: Y ou may need to provide combustion and ventilation air from an outside source to adequately satisfy local codes so avoid.
7 For conventional framing, where the oor joists are parallel with the sides of the rebox, the addition of oor joists to align with the anchor brackets allows the brackets to be directly connectedtotheoorjoists.
8 Grand Meridian W eight Determinations ThefollowingaredeadloadweightestimatesfortheGrandMeridianFireplace. T able I FireplaceModel MM39VF MM44VF MM49VF FireplaceWeight 809lbs. 896lbs. 987lbs. Mortar ,Rebar& ReadyMixConcrete 350lbs.
9 Clearances The Importance of Clearances W arning to the structural engineer and/or building contractor: It is your responsibility to be certain that t.
10 Interior W all Materials: W all materials, such as drywall, should be set ush with the rough front face of the V ent-Free replace.
11 Unconned Space An unconned space has a minimum total air volume of 50 cu.ft. (cubic feet) for each 1,000 Btu/Hr input rating of all appliances in the total space (cu.
12 Important Pre-installation Information Overview Y ou will nd that the Grand Meridian Fireplace is designed for completeassembly at yourconstruction sitewith allnecessary items delivered consistingof interlocking precast parts, 50 lbs.
13 Fireplace Assembly Procedures TOOLS NEEDED FOR INST ALLA TION: One4ft.level • Roto-hammerwith½”drillbit • DrillmotorwithmixerbladetomixMortar .
14 Figure 21 Combustion Air Access RightorLeft(Rightshown). Apply mortar Applymortar SideW all RearW all SideW all When you have arranged all the .
15 Raised and Flush Hearth Application: If you would prefer to have a raised hearth, the V ent-Free box can be raised to the desired height using wood studs or concrete blocks.
16 Firebrick Liner Installation It is required that the interior sides, rear and bottom be lined with minimum 1-1/8” thick rebrick. Pre-fabricated re brick liner wallscanmaketheinstallationeasier .
17 Appendi xI For installations regulated by the International Residential Code, the support foundation for the fireplace installed on concrete shal l consist of am inimum o f6i nche st hick reinforced concrete slab. The minimum specified compressive strength of f’ c ,s hall be as required in Table R402.
18 Appendi x I I FIGURE R301.2(3) WEATHERING PROBABILITY MA P F OR CONCRETE a. Alask a a nd Hawaii are classified as severe and negligible, respectively. b. Lines defining areas are approximate only. Local conditions may be more or less severe than indicated by region classification.
WARRANTY KEEP THIS WARRANTY FMI PRODUCTS, LL C LIMITED WARRANTIES New Products FMIPRODUCTS, LLCwarrants allGrandMeridian Fireplacesto befree fromdefectsin mat.
Een belangrijk punt na aankoop van elk apparaat FMI MM39/44/49VF (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen FMI MM39/44/49VF heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens FMI MM39/44/49VF vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding FMI MM39/44/49VF leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over FMI MM39/44/49VF krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van FMI MM39/44/49VF bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de FMI MM39/44/49VF kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met FMI MM39/44/49VF . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.