Gebruiksaanwijzing /service van het product 000 van de fabrikant Friedrich
Ga naar pagina of 20
840-170-38 Single Package V ertical Air Conditioning System B – Series 18,000 – 24,000 – 30,000 – 36,000 – 42,000 – 49,000 – 60,000 Btuh INST ALL A TION & OPERA TION MANUAL.
2 Page T ABLE OF CONTENTS V ert-I-Pak B -Series V ertical Air Conditioning System Safety Considerations ....................................................................................................... 3 General Recommendations .................
3 SAFETY CONSIDERA TIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or dealer for information and assistance.
4 MODELS: V(E,H)B18K05 V(E,H)B18K10 V(E,H)B24K05 V(E,H)B24K10 V(E,H)B30K10 V(E,H)B30K15 V(E,H)B36K10 V(E,H)B36K15 B-SERIES CHASSIS SPECIFICA TIONS Section I – General Specifications VERT-I-P AK ® M.
5 Cooling Cap. 42000 42000 48500 48500 58000 58000 Cooling Power (W) 4500 4500 5500 5500 6450 6450 SEER 9. 8 9.8 9 .8 9. 8 9.9 9 .9 Cooling SHR 0.72 0.72 0.69 0.69 0.72 0.72 ELECTRIC AL HEAT DA T A: Heater Size (KW) 10.0 15.0 15.0 20.0 20.0 25.0 Heating Cap.
6 The Vert-I-Pak was designed for installation in residential and light commercial applications. These instructions detail a typical method of installation.
7 Unit Configuration Figure 4 1) INDOOR AND OUTDOOR AIR REQUIREMENTS The indoor and outdoor air systems are designed to operate at specified airflow rates and external static pressures.
8 VPBWP4 – 8/14 Wall Plenum Figure 6 VPBWP3 – 8/14 Wall Plenum Figure 5 For Models • VE/VHB18 • VE/VHB24 For Models • VE/VHB18 • VE/VHB24 • VE/VHB30 • VE/VHB36.
9 VPBWP5 – 8/14 W all Plenum Figure 7 VPBWP6 – 8/14 W all Plenum Figure 8 For Models • VE/VHB42 • VE/VHB49 For Model • VE/VHB60.
10 B . . . . . Ducted Condenser Air For ducted outside air applications, the combined pressure losses of the intake and discharge air paths must not exceed the external static capabilities of the system at the design airflow (See Table 3).
11 C. Indoor -Air (Conditioned Supply Air) System The VEB/VHB series unit may be applied in either a free return air configuration or a ducted return air configuration.
12 2) Electrical A. Grounding CAUTION: The unit must be electrically wired and grounded in accordance with all state and local codes, national electric code, and NFPA 70. Unit and controls will NOT operate unless properly grounded. A ground lug is provided for ground connection.
13 B. Thermostat Mounting and Wiring The thermostat is a precision instrument and was carefully adjusted at the factory . Handle it carefully . CAUTION: Disconnect the power supply before beginning installation of the thermostat to prevent electrical shock or equipment damage.
14 4) CONDENSA 4) CONDENSA 4) CONDENSA 4) CONDENSA 4) CONDENSA TE DRAIN LINE TE DRAIN LINE TE DRAIN LINE TE DRAIN LINE TE DRAIN LINE The condensate drain exits the unit 2" above floor level at the right side front corner of the unit. The condensate drain line is already internally trapped therefore, no external condensate trap is required.
15 IDENTIFYING YOUR SYSTEM Take the time to familiarize yourself with the type of system you have. This knowledge will be of use in understanding the basic operation of your unit. A self-contained unit, like the Vert-I-Pak, has all of its major components in one cabinet located inside your home.
16 The temperature control is a selector or set of buttons that allows you to establish the degree of temperature that you wish to maintain for your personal comfort. Some thermostats have two temperature control selectors: one for setting the temperature desired during the cooling cycle, and one for setting the heating operation temperature.
17 System Control The SYSTEM or MODE control on your thermostat offers the following selections: COOL, OFF, HEAT, and EM HEAT. Neither the cooling nor heating equipment will operate when the SYSTEM or MODE control is set to OFF. With the SYSTEM or MODE control set to COOL, your unit will operate in cooling mode.
18 PERFORMING ROUTINE MAINTENANCE With the proper maintenance and care, your system will operate economically and dependably. Maintenance can be accomplished easily by referring to the following directions. However, before performing any maintenance, consider these important safety precautions: WARNING: Electrical Shock Hazard.
19 INSPECT AND CLEAN INDOOR-AIR COIL Eventually, minor amounts of lint and dirt may pass through the filter and collect on the indoor-air coil. These minor accumulations can be carefully vacuumed away with a brush attachment on a vacuum cleaner. Care must be taken to avoid bending the aluminum fins on the coil.
20 Use Factory-Certified Parts FRIEDRICH AIR CONDITIONING CO FRIEDRICH AIR CONDITIONING CO FRIEDRICH AIR CONDITIONING CO FRIEDRICH AIR CONDITIONING CO FRIEDRICH AIR CONDITIONING CO . . . . . P ost Office Box 1540 • San Antonio , T exas 78295-1540 4200 N.
Een belangrijk punt na aankoop van elk apparaat Friedrich 000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Friedrich 000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Friedrich 000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Friedrich 000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Friedrich 000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Friedrich 000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Friedrich 000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Friedrich 000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.