Gebruiksaanwijzing /service van het product 920-087-09 van de fabrikant Friedrich
Ga naar pagina of 36
I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l P T A C 92 0 -08 7 -09 (1 0/1 0 ) P a c k a g e d T e r m i n a l A i r C o n d i t i o n e r s & H e a t P u m p s.
.
2 T a b l e o f C o n t e n t s Con gratul atio ns ........................................................................................................................................................................................................
.
3 C o n g r a t u l a t i o n s Thank you fo r your dec isio n to purc hase Fri edr ic h. Y our new Friedr ic h has been car eful ly en ginee red and ma nufac ture d to give you many year s of depen dabl e, ef c ient op erat ion, maint aini ng a co mfor t ab le temp eratur e a nd humi dit y l evel.
4 G e n e r a l S p e c i f i c a t i o n s I n s t a l l a t i o n C h e c k l i s t q Inspec t all c ompone nts and ac ces sor ies for damage befor e and af ter insta llati on. q Remove the c ar dboar d wall sl eeve suppo r t and g ri ll weathe rb oard.
5 PT A C I n s t a l l a t i o n R e c o m m e n d a t i o n s PTAC un it s s ho u ld b e ins t al l ed no cl o s e r th a n 12 " ap a r t wh e n t wo u n i t s a r e s i d e b y s i de . I f thre e o r more PTA C un its are to oper ate nex t to on e anot her a llow a minimum of 3 6 " bet ween uni ts.
6 W a l l S l e e v e I n s t a l l a t i o n I n s t r u c t i o n s (P D XW S ) NOTE: Insure t hat th e unit is on ly inst alle d in a wall str uc tur ally ade quate to su ppor t the uni t incl uding t he sle eve, chassi s and ac ce sso ri es.
7 NOTE: Follow all wa ll system man ufac ture r i nsta llati on inst ruc ti ons. For sun roo ms and mo dular b uildi ngs, adh ere to th eir inst all atio n i nstr uc tio ns for suppo r ti ng and sealing sleeve to their fra mes. A ll wall and window/ wall installati ons must pr ovide for prop er drain age.
8 F ig u re 9 D i m e n s i o n s FRP007 NOTE: The Wall Sleeve must be horizontally level (side-to-side) and pitched 1/4 bubble to the outside when installed in an opening. The mounting hole location should be approximately 2-4” from the top and bottom of the sleeve.
9 FRP010 NO TE: Construct wall opening to comply with all applicab le building codes . MAIN STUDS JACK STUDS LINTEL MOUNTING SCREW HOLES NO HOLES IN BOTTOM OF W ALL SLEEVE UNLESS DRAIN KIT IS USED MAIN STUDS JACK STUDS 5.
10 FRP01 1 DRAIN TUBE SIDE VIEW FRONT VIEW W ALL SLEEVE OPTIONAL AREA PREFERRED AREA- NO FOAM INSULA TION IF THE DRAIN MUST BE LOCA TED IN THE OPTIONAL AREA, THE FOAM INSULA TION MUST BE CUT AW A Y AND REMOVED T O ALLOW ACCESS TO THE DRAIN.
1 1 FRP012 FOAM GASKET OVERFLOW SLOTS DET AIL B DET AIL A COVER PLA TE FOAM GASKET SCREWS ½” O.D. TUBE MOUNTING PLA TE NUT E x t e r n a l D r a i n ( f o r n e w c o n s t r u c t i o n o r u n i .
12 P X G A S t a n d a r d G r i l l e I n s t a l l a t i o n I n s t r u c t i o n s 1 . Remove t he c ente r su ppor t an d weat her boa rd if st ill inst alled in the sl eeve. 2. Inser t si x p lastic gr ommets into the gr ille o penings f rom the outside of the gr ill e as show n in Figu re 13.
13 W ARNING 15/20A LCDI Device 30A LCDI Device TEST BEFORE EACH USE 1. PRESS RESET BUTT ON 2. PLUG LCDI INT O POWER RECEPT ACLE 3. PRESS TEST BUTT ON, RESET BUTT ON SHOULD POP UP 4. PRESS TEST BUTT ON, FOR USE DO NOT USE IF ABOVE TEST F AILS WHEN GREEN LIGHT IS ON IT IS WORKING PROPERL Y RESET TEST W ARNING TEST BEFORE EACH USE 1.
14 T A BLE 2 Mo de l Hea te r k W Power Co rd K it Volta ge Am pe ra ge Rec ep ta cl e PDE07K 0.0 PXPC 23 0 0 0 23 0/ 20 8 15 NEM A 6 -15r PDE / PD H 07K 2.0 PXPC 23 015 2 30 /2 08 15 N EM A 6 -1 5r 3.0 STD 23 0/ 20 8 20 NEM A 6 -2 0r PDE0 9 K 0.0 PXPC 23 0 0 0 23 0/ 20 8 15 NEM A 6 -15r PDE / PD H 09 K 2.
15 3. Rout e t h e c ut en ds of h ar ne s s t hr ou gh t he c on dui t co nn ec to r asse mbly and ex c ondui t sl eeve. B e s ure to use the s uppli ed co nduit bus hing to pr event damage to th e co rd by the c onduit .
16 C h a s s i s I n s t a l l P r e p a r a t i o n C h e c k t o b e s u r e t h e w a l l s l e e v e , e x t e n s i o n ( i f u s e d) , g r i l l e , a n d d r a i n k i t a r e i n st a l l e d p r o p e r l y b e f o r e c h a s s i s i n s t a l l a t i o n .
17 FRP020 SHIPPING T APE F ig u re 20 S h i p p i n g T a p e Lo c a t i o n FRP021 REMOVE SHIPPING SCREW IF PRESENT F ig u re 2 1 S h i p p i n g S c r e w Lo c a t i o n F ig u re 22 R e m o v i n g F r o n t Pa n e l CAUTION Unit Damage Hazard Failure to follow this caution may result in equipment damage or improper operation.
18 1 . Lif t uni t level a nd sl ide unit into wa ll sl eeve unti l fr om s eal r ests r mly aga inst fr ont of wall s leeve. 2. Lo c ate t he f o ur su pp li e d c h as si s mo unt i ng s c rew s. I ns er t th e screws thro ugh t he ch assis mountin g ang e ho les t hat are aligned with the spee d nuts in the wall s leeve.
19 H o w T o C o n n e c t I M PO RT A NT : Pl e as e r e a d f o l l o w i n g e l e c t r i c a l sa f e t y d a t a c a r e f u l l y . 1 . Remove fro nt panel. S ee Figu re 22 . 2. Remove junc tio n box. • Remove junc tio n box c over by removing t hre e scre ws fr om fro nt.
20 F r i e d r i c h PT A C D i g i t a l C o n t r o l a n d U n i t F e a t u r e s The new Frie dri ch dig ital P T AC has stat e of the ar t feat ures to imp rove guest c omfo r t, in doo r air qualit y and c ons er ve ener gy.
21 Inst ant Heat Heat Pum p Mo de Heat pu mp mo dels w ill autom atic all y run t he el ect ri c heater to q uick ly br ing t he ro om up to te mper ature w hen ini tial ly ener gized, th en retu rn to h eat pump m ode.
22 S y s t e m C o n f i g u r a t i o n F r e s h Ai r V e n t C o n t r o l The vent co ntro l l ever is loc ated o n t he left side of the unit, behind the fro nt panel. NOTE: The vent door shippin g har dware must be removed b efore using the vent c ontr ol lever .
23 The adj usta ble c ontr ol dip sw itch es are lo cate d at the lowe r lef t hand p or t ion of t he digit al Sm ar t C enter . T he inp uts are o nly vis ible an d acc es sibl e wit h t he fro nt cover re moved fr om th e PT AC.
24 FRP030 High Med Low F an Cool Heat F an Speed Mode T emperature P ower °F v s . °C D i s p l a y Th e uni t is fa ct o r y c on gu re d to di sp lay a ll t em p er at ur es i n de gr ee s Fahrenhe it (° F). T o sw itc h to de gree s Ce lsius pres s the ‘Fan On ly ’ and ‘Low Fan’ but ton s simul tane ously for t hree sec onds.
25 R e m o t e C o n t r o l T h e r m o s t a t I n s t a l l a t i o n I n s t a l l Th e r m o st a t 1 . Appr oximate ly 5 f t. f rom t he o or . 2. Clos e to or in a f req uentl y u sed room, preferably on an inside wall. 3. On a sec ti on of wall w ith out pip es or du ct wor k.
26 D e s k C o n t r o l T e r m i n a l s The Friedr ic h PD model PT AC has built- in provi sion s for conne ct ion to an exter nal swit ch to c ont rol powe r t o t he unit. The swi tch ca n b e a c entr al desk c ontr ol syste m or even a nor mall y open d oor sw itc h.
27 q Inspe ct an d ensure that all c om pon ents an d acc es sor ies have been insta lled pro per ly and that they have not b een dama ged dur ing the insta llati on pr oc ess. q Chec k the condens ate water drai n(s ) to ensur e they are adequate for the rem oval of conde nsate water , and that they meet the ap proval of the en d user.
28 B a s i c T r o u b l e s h o o t i n g COM PL A IN T CAUSE SOLUTI ON Unit d oe s not o per ate. ● Unit turned off. ● T urn unit on ● Thermostat is satised. ● Raise/Lower temperature setting. ● LCDI power cord is unplugged. ● Plug into a properly grounded 3 prong recep- tacle.
29 COM PL A IN T CAUSE SOLUTI ON Unit d oe s not c oo l/ h eat ro om s uf ci ent ly, or cycle s on an d of f to o fr eque ntl y ● The air conditioner has insufcient heating capacity to match the heat loss of the room. ● Check the heating capacity of your unit.
30 New Co ns tr uc t io n Acc es sor ie s PDXWS PDXWS E X T WALL SLE EV E Ga lvanize d zinc c oated st eel is p repar ed in an 1 1- step pr oc ess, then p owder c oate d wit h a polye ster ni sh and c ured i n an oven for except ion al durab ilit y.
31 New Co ns tr uc t io n Acc es sor ie s PXCJA COND UI T KI T WI TH JU NCT IO N BOX Har d wire c on duit ki t wit h junct io n box for 208 /2 30V an d 265 V uni ts (subbase not r equir ed). Kit in clud es a me ans of quic k disc onne ct fo r easy rem oval of the c hass is.
32 Frie dr ic h Air C ond it io ni ng Co mp any 100 01 Reunion P lac e, Suite 5 0 0 San A ntonio, T X 78216 21 0.3 57 . 44 0 0 w w w.frie dri ch.c om R O O M AI R C O N D IT I O N E R S L I M I T E D .
.
33 F riedrich A ir Conditioni ng Co. 100 01 Reunion P lace, Suite 50 0 • San A ntonio, T exas 78216 (210) 357 - 4 4 0 0 • F A X (210) 357 - 4 4 8 0 ww w .
Een belangrijk punt na aankoop van elk apparaat Friedrich 920-087-09 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Friedrich 920-087-09 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Friedrich 920-087-09 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Friedrich 920-087-09 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Friedrich 920-087-09 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Friedrich 920-087-09 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Friedrich 920-087-09 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Friedrich 920-087-09 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.