Room Air Conditioner Ser vice and P ar ts Man ual C P05 / C P06 (0 6 /0 5 ) CP05A10 CP06A10.
—2— CONTENTS 1. PREF A CE ...................................................................................................................................................3 1.1 FEA TURES...........................................................
—3— 1. PREF A CE This ser vice manual provides v arious ser vice inf or mation, including the mechanical and electr ical par ts, etc. This room air conditioner was manuf actured and assembled under a strict quality control system. The refrigerant is charged at the f actory .
—4— 1.3 LOCA TIONS OF CONTROLS 1.4 SAFETY PRECA UTIONS 1. When se r vicing, turn the unit Off and unplug the p o w er cord. 2. Obser ve the original lead dress. If a shor t circuit is found, replace all parts which have been ov erheated or damaged by the shor t circuit.
— 5 — 2. DISASSEMBL Y INSTR UCTIONS 2.1 MECHANICAL P AR TS 2.1.1 FRONT GRILLE 1. Pull the inlet grille f orw ard. 2. Remov e the screw securing the F ront Gr ille. (Fig. 3) 3. Push the grille up from the bottom and pull the top of the grille aw a y from the case to lift the top tabs out of their slots.
— 6 — 2.2 AIR HANDLING P AR TS 2.2.1 AIR GUIDE UPPER 1. Disconnect the unit from the power source . 2. Remov e the front grille. (Refer to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Remov e the control board. (Ref er to Section 2.
— 7 — 2.2.3 MO T OR 1. Disconnect the unit from the power source . 2. Remov e the front grille. (Refer to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Remov e the control board. (Ref er to Section 2.1.3) 5. Remov e the air guide upper .
— 8 — 2.3.2 COMPRESSOR 1. Remov e the front grille and cabinet. (Ref er to Section 2.1) 2. Discharge the refrigerant by using a refrigerant recov er y system. 3. Remov e the overload protector . (Ref er to Section 2.3.1) 4. After discharging the unit completel y , unb r aze the suction and discharge pipes at the compressor connections.
— 9 — 2.3.6 PO WER CORD 1. Disconnect the unit from source of power . 2. Remov e the front grille. (Refer to Section 2.1.1) 3. Remov e the cabinet. (Refer to Section 2.1.2) 4. Remov e a screw that secures control board to base pan. (Ref er to Section 2.
2.4.2 E V APOR A T OR /CONDENSER 1. Remov e the cabinet. 2. Discharge the refrigerant by using a refrigerant recov er y system. 3. Remov e the air guide upper . (Refer to Section 2.2.1) 4. After discharging the refrigerant completely , unb r a z e the interconnecting tube at the proper coil connection s .
— 11 — Equipment needed: V acuum pump , charging cylinder , manifold gauge , brazing equipment, pinch-off tool capable of making a v apor proof seal, leak detector , tubing cutter , hand tools to remove components and service valv e.
— 12 — 3 . T R OUBLESHO O TING GUIDE 3 .1 OUTSIDE DIMENSIONS (unit: mm [in]) 370 (14 9 / 16 ") 312 (12 1/4 ") 370 (14 9 / 16 ") 312 (12 1/4 ") 29 (1 5 / 32 ") 120 (4 3 / 4 ") 27.5 (1 3 / 32 ") 346 (13 5 / 8 ") 472 (18 9/16 ") 42 (1 21 / 32 ") 42 (1 21 / 32 ") 155(6 3/32 ") 12 (0.
— 13 — 3 .2 PIPING SYSTEM F ollowing is a brief description of the impor tant components and their function in what is called the refr igeration system. Re f erence should be made to Figure 22 to f oll o w the ref r ige r ation cycle and the fl o w of the ref r ige r ant in the cooling cycle.
— 14 — 3 .3 T R OUBLESHO O TING GUIDE In gene r al, possi b le trou b le is classified in t w o categories. The one is called Starting Failure which is caused b y an electrical defect. The other is Ineff ective Air Con- ditioning caused b y a de f ect in the ref r ige r ation circuit and/or improper application.
— 15 — Fails to Start Improper thermostat setting Loose ter minal connection Improper wiring Che c k p o w er sourc e . Drop of pow er voltage . Capacitor check. Replacement. Che c k control s witch setting. Compressor f ails to star t. Def ect of compressor capacitor .
COMPLAINT CA USE REMED Y F an motor will not run. No power Check v oltage at outlet. Correct if none. P ower supply cord Check v oltage to rotar y switch. If none , check power supply cord. Replace cord if circuit is open. Wire disconnected or Connect wire.
— 17 — COMPLAINT CA USE REMED Y F an motor noise. F an If crac ked, out of balance , or par tially missing, replace it. Blow er If crac ked, out of balance , or par tially missing, replace it. Loose set screw Tighten it. W orn bear ings If knocking sounds contin ue when running or loose, replace the motor .
— 18 — COMPLAINT CA USE REMED Y Compressor cycles on F an motor If not running, deter mine the cause. Replace if ov er load. required. Condenser air flow Remo ve the cabinet, inspect the interior surf ace restriction of the condenser . If restricted, clean carefully with a v acuum cleaner (do not damage fins) or brush.
— 19 — 4 . CIRCUIT DI A GRAM WH(BL) POWER INPUT BK(BR) (Ribbed) (Plain) GN/YL (GN) GN/YL(GN) THERMIST OR BK BK BL RD BL RD CN-TH1 YL YL OR(BR) OR(BR) OR SYNC M OTOR R Y -LO R Y -HI CN-WORK CN-SYNC CN-DISP DISPLA Y P .W.B ASM R Y -SYNC 250V/T2A (115V/T2A) TRANS FORMER ZNR 43 R Y -COMP MAIN P .
— 20 — 5 . EXPLODED VIEW 352390 130410 359012 W48602 354210 349480 352380 149980 559011 346811 554030 W48602 130910 550140 554160 567502 352115 352111 352113 35211A 135313 152302 135312 132111-2 1.
— 21 — 6 . SE R VICE P A R TS LIST • C P05A10 C P06A10 R: Service Parts N: Non Service Parts • Loc No FRIEDRICH Description 130410 67302921 BASE ASSEMBLY,WELD[SINGLE] 130910 67303709 CABINET A.
Loc No FRIEDRICH Description 130410 67302921 BASE ASSEMBLY,WELD[SINGLE] 130910 67303709 CABINET ASSEMBLY,SINGLE 135312 67306008 GRILLE ASSEMBLY,FRONT(SINGLE) 135313 67306107 GRILLE,INLET 137215 673055.
— 23 — MEMO.
Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4490 FRIEDRICH AIR CONDITIONING CO.
Een belangrijk punt na aankoop van elk apparaat Friedrich CP05A10 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Friedrich CP05A10 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Friedrich CP05A10 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Friedrich CP05A10 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Friedrich CP05A10 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Friedrich CP05A10 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Friedrich CP05A10 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Friedrich CP05A10 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.