Room Air Conditioner Ser vice and P ar ts Man ual CP06 CP08 SVC PARTS 2008(07/08) C P 08 E 1 0 CP06E10 0 F Power Mode Timer 0 n / 0ff Fan Speed Temp Cool Money Saver ® Fan Only Dry hr Auto Swing.
2 Room Air Conditioner Air Conditioner Ser vice Manual T ABLE OF CONTENTS Safety Precautions ..........................................................................................................................................3 Dimensions .......
Ser vice Manual 3 Saf ety Precautions Safety Precautions T o pre v ent injury to the user or other people and proper ty damage, the f ollo wing instructions must be f ollo w ed. Incorrect ope r ation due to igno r ing inst r uctions will cause ha r m or damag e .
4 Room Air Conditioner Saf ety Precautions Plug in the power plug properl y . • Otherwise , it will cause elect r ic sho c k or fire. Do not operate or stop the unit b y inserting or pulling out the power plug. • It will cause electric shock or fire.
Ser vice Manual 5 Saf ety Precautions CAUTION • • • • • If water enters the pr oduct, turn off the the power s witch of the main bod y of appliance. Contact service center after taking the power - plug out from the soc ket. • It will cause electric shock or f ailure of machine.
6 Room Air Conditioner Dimensions Dimensions Outside Dimensions This symbol alerts you to the risk of electric shoc k. This symbol alerts you to hazar ds that could cause harm to the air conditioner .
1Ø, 115, 60H z INDOOR ( C) 26.7(DB)* 19.4(WB)** OUTDOOR ( C) 35(DB)* 23.9(WB)** 490g(17.3 oz) Ø7.0, 2ROW 14S TACKS Ø5.0, 2ROW 16S TACKS TURBO FAN PROPELLER TYPE FAN WITH SLINGER RIN G 3/3 6 POLES R.
Operation Location and Function of Contr ols • DESIGNED FOR COOLING ONLY • POWERFUL AND INCREDIBLE COOLING • TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE • BUILT-IN ADJUSTABLE THER.
A i r P u r i f ie r P o w e r T e m p Mo d e T i m e r A S wi n g F a n S p e e d 1 2 4 3 5 Auto Swing 6 0 F P ower Mode Timer 0n / 0 ff Fan Speed T emp Cool Money Saver ® Fan Only Dry hr Auto Swing 1 3 2 4 6 5 7 6. A UT O SWING This button can automatically control the air flo w direction (left+right) .
Disassembly Disassem b l y Mechanical Parts — Before the following disassembly, POWER SWITCH set to OFF and disconnect the power cord. 1. F R ONT GRILLE 1. Open the lnlet grille upward or downward. 2. Remove the screw which fastens the front grille.
1 1 Room Air Conditioner Disassembly Air Handling P ar ts — 7 — 1 . AIR GUIDE AND BL O WER 1. Remove the front grille. 2. Remove the cabinet. 3. Remove the control box. 4. Remove the 3 screws which fasten the brace. 5. Remove the brace. 6. Remove the 2 screws which fasten the evaporator.
Se r vice Ma n ual 1 2 Electrical P ar ts 1. Remove the cabinet. 2. Remove the evaporator. 3. Remove the orifice. 4. Remove the blower. 5. Remove the fan. 6. Remove the control box cover and housing of the motor in the control box. 7. Remove the 2 screws which fasten the motor from the mount motor.
Se r vice Ma n ual 1 3 Disassembly 4 . P O WER CORD Refrigerating Cycle CA UTION: Discharge the refrigerant system using a Freon TM Recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon TM .
14 Room Air Conditioner Disassembly — Replacement of the refrigeration cycle. 1. When replacing the refrigeration cycle, be sure to Discharge the refrigerant system using a Freon TM recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the Freon TM .
Se r vice Ma n ual 15 Disassembly Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pin-off tool capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service valve.
Se r vice Ma n ual 16 Schematic Diagr am Cir cuit Diagram LOCATION NO. 1 2 3 4 5 6 7 8 Q'TY PER SET 1 1 1 1 1 1 1 1 DESCRIPTION POWER CORD ASSEMBLY FAN MOTOR COMPRESSOR DISPLAY P.
17 Room Air Conditioner Electr onic Control De vice Schematic Diagram.
Se r vice Ma n ual 18 Components Location(For Main P .W .B ASM) Schematic Diagr am.
19 Room Air Conditioner T roubleshooting Guide T r oubleshooting Guide Piping System Figure 38 is a brief description of the important components and their function in what is called the refrigeration system. This will help you to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle.
Se r vice Ma n ual 20 T roubleshooting Guide T roub leshooting Guide In general, possible trouble is classified in two kinds. The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.
2 1 Room Air Conditioner T roubleshooting Guide Fails to Start Improper thermistor setting Loose terminal connection Improper wiring Check of power source. Drop of power voltage. Capacitor check. Replacement. Check of control panel setting. Compressor fails only to start.
Se r vice Ma n ual 2 2 T roubleshooting Guide ELECTRIC P AR TS TROUBLESHOO TING GUIDE: P ossible T rouble 1 • The unit does not operate. Is the Trans input power AC 115V? Is the Trans output power about AC 14V? Is shorted the Trans. output? Is output Voltage of IC01D DC 12V? Is output Voltage of IC02D DC 5V? Is the voltage No.
23 Room Air Conditioner T roubleshooting Guide Is Temp. setting set lower than Room Temp.-0.5 ° C? Is the voltage No.10 of IC01M 0V? • Exchange IC01M. • Set the Temp. setting to lower Temp. • Wait 3 Minutes Is the Unit for 3 minutes delay? • Exchange MAIN P.
Se r vice Ma n ual 24 T roubleshooting Guide Is the voltage of Battery about over 2.3V? • Exchange Receiver Ass'y. Is the connection of CN-DISP1 all right? Is the voltage No.16 of CN-DISP1 on Main P.W.B Ass'y DC 5V? • Exchange the battery.
25 Room Air Conditioner T roubleshooting Guide ROOM AIR CONDITIONER VOLTAGE LIMITS NAME PLATE RATING MINIMUM MAXIMUM 115V ± 10% 103.5V 126.5V COMPLAINT CAUSE REMEDY Fan motor will not run. No power Check voltage at outlet. Correct if none. Power supply cord Check voltage to rotary switch.
Se r vice Ma n ual 26 T roubleshooting Guide COMPLAINT CAUSE REMEDY Fan motor noise. Fan If cracked, out of balance, or partially missing, replace it. Blower If cracked, out of balance, or partially missing, replace it. Loose set screw Tighten it. Worn bearings If knocking sounds continue when running or loose, replace the motor.
27 Room Air Conditioner COMPLAINT CAUSE REMEDY Compressor cycles on Voltage Check the voltage. See the limits on the overload. preceding page. If voltage is not within these limits, call an electrician. Overload Check overload, if externally mounted. Replace if open.
Ser vice Man ual 2 8 Exploded Vie w Exploded Vie w 249950 567480 268711-1 264110 238310 237200 268711-2 135510 146812 W0CZZ 554030 559010 552113 35211A 352113 352115-1 352115-2 731273 267110 552102 13.
2 9 Room Air Conditioner R e p l a c e m e n t P a r t s l i s t LocNo CP06E10 CP08E10 DESCRIPTION REMARK 130410 67302912 67302905 Base As sy Single R 349001 67303502 67303502 Damper A ssembly R 13091.
CP06 CP08 SVC P ARTS 2008(07/08) Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4490 FRIEDRICH AIR CONDITIONING CO. Visit our web site at www.friedrich.com Use F actor y Cer tified P ar ts.
Een belangrijk punt na aankoop van elk apparaat Friedrich CP08E10 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Friedrich CP08E10 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Friedrich CP08E10 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Friedrich CP08E10 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Friedrich CP08E10 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Friedrich CP08E10 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Friedrich CP08E10 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Friedrich CP08E10 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.