6 61214 17 (4- 0 6) O p e r a t i n g G u i d e C o m p a c t Pr o g r a m m a b l e R o o m A i r C o n d i t i o n e r w i t h re m o te c o n t r o l C P18C30 Whene ver yo u call to req uest ser vice on your appliance, you w ill need to pro vide you r compl et e mod el numb er and serial number .
2 T a b l e o f C o n t e n t s Air C ondit ioner S afet y ...................................................................................................................................................... 2 Inst alla t ion Requirement s .........
3 3 I n s t a l l a t i o n R e q u i r e m e n t s T o o l s a n d P a rt s Gather the r equired tools and parts befor e starting installation. Read and follow the instructio ns provided with any tools listed here .
4 4 W in do w in st al la ti o n Window op en ing measureme nts : 30"mi n. t o 40" ma x. ( 76.2 c m to 101.6 cm ) op ening wi dt h. 20" mi n. ( 50.8 c m ) op en ing height . T hr ou gh -t h e- wa l l i ns ta l la ti on Th e w all opening measuremen ts should b e: Widt h: 30" (76.
5 5 R ec om men de d gr ou nd in g me th od Th is air cond i tioner mu st b e ground ed. This ai r co nd itio ner is equip p ed with a po we r supp ly c ord havi ng a ground ed 3 pr ong p lug.
6 6 I n s t a l l a t i o n I n s t r u c t i o n s U n p a c k i n g R em o ve p ac ka gi ng m a te ri al s � Remove and dispose of/ recycle packaging materials. Remove tape and glue r esidue from surfaces befor e tur ning on t he air conditioner .
7 7 W i n d o w I n s t a l l a t i o n ( o n s o m e m o d e l s ) NOTES: � Handle air conditioner gently . � Be sure y our air conditioner cabinet does not fall out of the opening during installation or r emoval.
8 8 I ns ta l l C ab in et i nt o W in d ow � Handle air conditioner gently . � Be sure y our air conditioner cabinet does not fall out of the opening during installation or r emoval. � The place wher e the power cord exits the air conditioner should be no mor e than 4 ft (122 cm) from a gr oun ded 3 prong ou tlet.
9 9 2. Using #10 x ⁷⁄₈ " pan-head Phillips scre ws, attach bracket to cabinet. Repeat for other bracket. 3. T urn the adjustment bolt for each bracket until the bolt touches the wall. 4. T urn the locking nut on adjustment bolt to lock in position.
10 10 � Use 1" (2.5 cm) or thicker lu mber for wood frame. 4. Apply wood pr eservative to the outside exposed surf ace. 5. Insert the fra me in the wall opening. Squar e and level frame. 6. Attach frame secur ely to the wall. I ns ta ll C a bi ne t i nt o W o od F ra me 1.
1 1 11 3. Connect gr een ground wir e to cabinet base with ground screw . Position ground wire pointing straight up. Put excess gr ound wire be tween coil and air conditioner cabinet. 4. Push front panel straight on and then lower it sli ghtly to loc k i t into place.
12 S t a rt i n g Y o u r A i r C o n d i t i o n e r — D i g i t a l C o n t r o l 1. Pre ss P OW E R to t urn o n ai r co nd it io ner . NOTE : Whe n th e u nit is tu rn ed on, it w ill di sp lay th e previous se tti ngs f or th e Mo d e, F an Spee d and t emp e ra t ure.
13 13 T o o pe ra te a ir c on di ti on er w it h r em ot e co nt r ol NOTE: R emote con t rol may vary in a ppe arance. NOTE : T wo AA A b a tt er ies ( inc lud ed) po w er the remote c o nt rol. R eplac e batte ries a ft er 6 mo nt hs of use, or w hen th e re m ot e c ont rol st arts to l ose po wer .
14 A i r C o n d i t i o n e r C a r e Y our n e w air c o nd iti oner is desig ned to gi ve you many yea rs o f dep endab le service . Th i s sect io n tells you how t o cl ean and ca re for you r air con d it ioner properl y . Call your lo cal auth orized d ealer for an annual checku p .
15 1 5 A ir c on di ti on e r po we r s up pl y c or d tr ip s ( Re se t b ut to n p op s o ut ) � Disturbances in your e lectrical current can trip (Reset button will pop out) the power supply cord. Press and rele ase RESET (listen for click; Reset button will latch and remain in) to resume operation.
Friedrich A ir Conditioning Company P.O. Box 1540 San Antonio, TX 78295 21 0. 35 7.4 400 ww w.f rie dri ch. co m ROOM AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR ANY PA R T: If any part supplied by F.
Een belangrijk punt na aankoop van elk apparaat Friedrich CP18C30 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Friedrich CP18C30 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Friedrich CP18C30 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Friedrich CP18C30 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Friedrich CP18C30 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Friedrich CP18C30 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Friedrich CP18C30 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Friedrich CP18C30 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.