Gebruiksaanwijzing /service van het product MS24Y3F van de fabrikant Friedrich
Ga naar pagina of 29
CONTENTS SPECIFICATIONS ................................ 1 OUTLINE AND DIMENSIONS ..................... 2 REFRIGERANT SYSTEM DIAGRAM .............. 4 ERROR CONTENTS ............................ 7 CIRCUIT DIAGRAM .............................. 5 PCB CIRCUIT DIAGRAM .
SPECIFICA TIONS TYPE INDOOR UNIT OUTDOOR UNIT COOLING CAP ACITY PO WER SOURCE FREQUENCY RUNNING CURRENT (Heat) INPUT W A TTS (Heat) E.E.R. (Heat) MOISTURE REMO V AL AIR CIRCULA TION-High ELECTRICAL DA.
OUTLINE AND DIMENSIONS INDOOR UNIT Unit : inch (mm) 39-1/8" (990) 19-3/4" (500) 4-23/32" (120) 35" (900) 25-7/8" (655) 20-7/8" (530) 7-27/32" (199) 2-3/4" (70) 7-7/8" (200) 6-7/8" (175) 7-7/8" (199) (rear view) 2 2006.
Unit : inch (mm) OUTDOOR UNIT 3"(77) 35-1/2" (900) 32-3/4" (830) 17-3/8" (440) 7/8" (21) 3/8" (9) 15-3/4" (400) 13" (330) 1-1/4" (31) 1/2" (12) 7-3/4" (196) 5-3/4" (147) 6-3/4" (170) 3-7/8" (99) 14-5/8" (370) 25-5/8" (650) Air Flow 3 2006.
REFRIGERANT SYSTEM DIAGRAM : COOL : HEAT Evaporator OUTDOOR UNIT Pressure Check Valve Condenser 4-way Valve High Pressure Switch Accumulator Muffler Compressor Expansion Valve Refrigerant Pipe 9.52mm (3/8") Charging Valve Charging Valve Refrigerant Pipe 15.
CIRCUIT DIAGRAM INDOOR UNIT TERMINAL STEP MO T OR ( LEFT / RIGHT ) STEP MO T OR (U P/D O W N) F A N M OTO R CAP A CITOR F A N M OTO R ROOM TEMPERA TURE THERMIST OR PIPE TEMPERA TURE THERMISTOR FM M M 1 2 31 2 3 Use T3.
OUTDOOR UNIT ORANGE YELLOW WHITE BLUE BRO WN RED BLUE YELLOW WHITE BLACK RED BLACK BLACK RED RED BLACK BRO WN BLUE BRO WN BLACK RED BRO WN BLACK BLACK WHITE BLACK BLACK WHITE WHITE GREEN BLACK WHITE B.
CONTROLLER PCB ASSY K01AL-050SHSE-C1 INDOOR PCB CIRCUIT DIAGRAM 7 2006.05.25.
POWER SUPPL Y PCB ASSY K04BA-0500HUE-P0 CONTROLLER PCB ASSY K04A W-0502HUE-C1 INVERTER ASSEMBL Y EZ-005FHUE OUTDOOR PCB CIRCUIT DIAGRAM 8 2006.05.25.
600/450V x 4 OUTDOOR UNIT CONTROLLER PCB ASSEMBL Y K04A W-0502HUE-C1 9 2006.05.25.
5V TM101 TM102 C1 12 0.015 <YE> C1 13 0.015 <YE> C1 1 1 3.3 <LE> L4 RCH4730-021PF07 C107 3.3 <LE> TM100 L2 N200500K1D7C CT1 CT -1B 5V D60 DAN217U C64 0.1 <F> R68 22K <1/10W> C65 0.1 <F> VR1 B2K + R61 3.74K <1/10W> (1%) C60 220/16V <PJ> R60 1.
ERROR CONTENTS (Indoor unit) Operation can be checked by lighting and flashing of the display section OPERATION, , and TIMER lamps. Perform judgment in accordance with the following.
ERROR CONTENTS (outdoor unit) 1. Make a TEST RUN in accordance with the in- stallation instruction sheet for the indoor unit. 2. OUTDOOR UNIT LEDS Error contents Communication error (Indoor unit - Out.
DISASSEMBLY ASSEMBLY INDOOR UNIT 13 2006.05.25 653-2 365-1 365-2 365-2 365-1 870-1 653-2 870-1 509 173 580 508 174 240 743.
14 2006.05.25 INDOOR UNIT 196-1 184-1 470 764 577 127 124 235 124 108 68 578 418 160 439 138 68 187.
15 2006.05.25 983 983 INDOOR UNIT.
416 417 385 771 488 472 473 443 8-1 16 2006.05.25 INDOOR UNIT.
17 2006.05.29 800 652-1 735 146 OPTIONAL P AR TS INDOOR UNIT.
18 2006.06.13 INDOOR UNIT 982.
684 558 555 554 520 521 505 505 505 321 320 361 69 69 69 69 502 505 506 500 407 408 503 876-2 876-1 361-2 361-2 361-2 361-3 361-3 361-3 361-2 19 2006.05.
1 6 3 4 5 2 20 2006.05.29 OUTDOOR UNIT.
17 18 10 13 11 9 15 14 8 OUTDOOR UNIT 2006.06.13 21.
22 23 31 20 29 12 28 12 19 24 26 27 25 30 22 2006.05.29 OUTDOOR UNIT.
37 38 33 34 36 35 23 2006.05.29 OUTDOOR UNIT.
PARTS LIST INDOOR UNIT Ref. Part No. Ord. Ref. Part No. Ord. No MS24Y3F Q'ty No MS24Y3F Q'ty 8-1 Air Filter 67220192 500 Protect Cover 67220242 34 Capacitor (Fan Motor) 67220218 502 SupportS.
OUTDOOR UNIT Ref. Part No. Ord. No MR24UY3F Q'ty 1 Top Panel Sub Assy 67201640 2 Front Panel 67201601 3 Fan Guard 67201602 4 Grip Side 67201603 5 Service Panel Sub Assy 67201688 6 Right Panel 672.
1 1 2 1 1 1 4 4 1 1 4 2 6 1 1 1 1 Q'ty INDOOR UNIT ACCESSORIES Name and Shape Part No. Application For positioning the indoor unit. For under ceiling type. For suspending the indoor unit from ceiling. For suspending the indoor unit on the wall. For fixing the wall bracket.
1 1 2 2 For remote control unit holder installation Use for air conditioner operation (AR-JW5) For remote control unit Use are remote control unit holder 9371190051 0600185534 9305642014 0700019098 Remote control unit holder Tapping screw Remote control unit Battery (penlight) Q'ty REMOTE CONTROL UNIT Name and Shape Part No.
0605G3090.
Een belangrijk punt na aankoop van elk apparaat Friedrich MS24Y3F (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Friedrich MS24Y3F heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Friedrich MS24Y3F vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Friedrich MS24Y3F leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Friedrich MS24Y3F krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Friedrich MS24Y3F bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Friedrich MS24Y3F kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Friedrich MS24Y3F . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.