Gebruiksaanwijzing /service van het product SP05A10 van de fabrikant Friedrich
Ga naar pagina of 28
SERVICE Manual CONTENTS AIR CONDITIONER 1 1. Precautions 1 2. Product Specifications 1 3. Installation and Operating Instructions 1 4. Disassembly and Reassembly 1 5. T roubleshooting 1 6. Exploded Views and Parts List 1 7. Block Diagram 1 8. PCB Diagram 1 9.
1. Precautions FRIEDRICH AIR CONDITIONING CO. 1-1 1. Precautions 1. W arning: Prior to repair , disconnect the power cord fr om the circuit br eaker . 2. Use proper parts: Use only exact replacement parts. (Also, we r ecommend replacing parts rather than r epairing them.
2.Product Specifications 2-1 T able Item Unit of Measure SP05A10 REMARK T ype WINDOW Dimension: (Width × Height × Depth) mm 424 × 310 × 326 V olt age V olt 1 15 Phase - SINGLE Frequency Hz 60 Operation Current A 4.6 Power Consumption W 500 Refrigerant T ype FREON R22 Refrigerant Change g 300 Capacity BTU/h 5400 EER BTU/h.
MEMO 2-3 FRIEDRICH AIR CONDITIONING CO. DB98_04511A(2)-1 2/18/03 4:09 PM Page 2-4.
2-2 Dimensions 2-2-1 Main Unit 2-2-2 Remote Control 2-2 Dimensions 2-2-1 Main Unit 2-2-2 Remote Control 2-2 Dimensions 2-2-1 Main Unit 2-2-2 Remote Control 2-2 Dimensions 2-2-1 Main Unit 2-2-2 Remote Control 424 310 310 Front view Side view (Unit : mm) 2-4 FRIEDRICH AIR CONDITIONING CO.
FRIEDRICH AIR CONDITIONING CO. 3-1 3. Installation and Operating Instructions 3-1 Installation 3-1-1 Selecting Area for Installation 1. Make sure that you install the unit in an ar ea providing good ventilation. The air conditioner must not be blocked by any obstacle affecting the air flow near the air inlet and air outlet.
3-2 Function Description 3-2-1 Cooling operation mode The compressor is turned on and of f according to the ambient temperatur e and set temperature. 1) Compressor on and of f control • Compressor o.
FRIEDRICH AIR CONDITIONING CO. 3-3 3-2-4 Sleep operation mode 1) Enable to sleep operation only when cooling operation. 2) First, 7-SEG LED DISPLA Y "SLEEP" while 15 second, Second, 7-SEG LE.
MEMO 3-4 FRIEDRICH AIR CONDITIONING CO. DB98_04511A(2)-1 2/18/03 4:09 PM Page 2.
FRIEDRICH AIR CONDITIONING CO. 4-1 4. Disassembly and Reassembly 4-1 Compressor Replacement Flow Chart Locate cause of defect Release refrigerant Disconnect electrical wiring from compressor Cut refri.
4-2 FRIEDRICH AIR CONDITIONING CO. 4-2 Checking the oil 4-2-1 Oil quality 4-2-2 Replacing and refilling the refrigerant oil 1. Change the compr essor - DO NOT r echarge the oil as the compr essor itself is already char ged. 2. Change the condenser ...
4-3.Disassembly and Reassembl y Procedure(SP05A10) Stop operating the air conditioner , and pull out the pow er cord before repair . No. Part Name Procedures Remarks 1 Ass’y Grille 1.Pull the Grille air inlet and Guard air filter out. 2.Remove the screw on the p anel front.
Disassembly and Reassembly Procedure(SP05A10) No. Part Name Procedures Remarks 4 CASE EV AP UP & ASSY EV AP 1.T ake the case evap up forward carefully . (tear all the seal on it before ) 2.Pull the frame up upward. 5 Blower 1.Remove all screws on the evaporator .
FRIEDRICH AIR CONDITIONING CO. 5-1 5. T roubleshooting 5-1 Basic Checkpoints for T roubleshooting Check the basic checkpoints first to determine whether it is machine tr ouble or a problem in the operation method. When it is not r elated to the basic checkpoints, perform checking in accordance with the pr ocedures of tr oubleshooting by symptom.
5-2 FRIEDRICH AIR CONDITIONING CO. 5-2 T roubleshooting by Symptom 5-2-1 No power 1) Check points (1) Is the voltage of the power sour ce normal ? (the rating voltage ± 10% range.) (2) Is the electric wir e in good contact ?(CN 71, R Y 71) (3) Is the output voltage of the IC01(KA 7812) normal ?(DC 1 1.
FRIEDRICH AIR CONDITIONING CO. 5-3 T roubleshooting 5-2-2 When the Touch Key pad and Led Display 1) Check points (1) Is the voltage of the power sour ce normal ? (the rating voltage ± 10% range.
5-4 FRIEDRICH AIR CONDITIONING CO. T roubleshooting 5-2-3 When the remocon is not operated 1) Check points (1) Is the voltage of the power sour ce normal ? (the rating voltage ± 10% range.
FRIEDRICH AIR CONDITIONING CO. 5-5 T roubleshooting 5-2-4 When the compressor is not operated 1) Check points (1) Is the voltage of the power sour ce normal ? (the rating voltage ± 10% range.
FRIEDRICH AIR CONDITIONING CO. 5-7 T roubleshooting 5-2- 5 When the fan motor does not operated 1) Check points (1) Is the voltage of the power sour ce normal ? (the rating voltage ± 10% range.
FRIEDRICH AIR CONDITIONING CO. 6-1 6. Exploded V iew and Parts List 6-1 Main unit DB98_04511A(2)-2 2/18/03 4:12 PM Page 6-1 EXPLODED VIEW SP05A10 4 6 7 8 9 10 11 13 12 14 16 17 18 19 20 32 22 23 24.
Exploded View and Parts List ■ Part List No Description Code No. Specification Q'TY SP05A10 1 ASSY PANEL FRONT DB92-00393B ASSY,TOP,SEA 1 1-1 PANEL FRONT DB64-00680A HIPS,T2 1 1-2 BLADE V DB66-00367A HIPS,T2.0 4 1-3 LINK BLADE DB66-00368A PP,L82,T1.
FRIEDRICH AIR CONDITIONING CO. 7-1 7. Block Diagram 7-1 Refrigerating Cycle Block Diagram PINCH PIPE (SERVICE VALVE) SUCTION LINE ACCUMULATOR/COMPRESSOR EVAPORATOR CAPILLARY TUBE CONDENSER DISCHARGE L.
7-2 FRIEDRICH AIR CONDITIONING CO. Block Diagram 7-2-2 Micom pin assignment KS88C4716 GRID5 SEG-DA T A(d) SEG-DA T A(e) SEG-DA T A(f) SEG-DA T A(g) SEG-DA T A(h) SEG-DA T A(a) EEPROM CLK EEPROM IN EEP.
Back Side Front Side MAIN PCB:DB93-00874U 8. PCB DIGRAM 8-1 ASSY MAIN PCB FRIEDRICH AIR CONDITIONING C0. 8-1.
PCB PARTS ■ Part List DB93-00874U NO. DESCRIPTION SPECIFICATION Q'TY REMARK 1 DIODE BRIDGE DE06S 1 BD01 2 VARISTOR 10D 471 1 VA71 3 IC DRIVE ULN2003AD 2 IC04,IC06 4 IC KA7533OZ 1 IC03 5 IC-VOLT.
FRIEDRICH AIR CONDITIONING CO. 9-1 9. Wiring Diagram DB98_04511A(2)-2 2/18/03 4:12 PM Page 10-3 SENSOR THERMISTOR CN41 CN12 +12V F701 250V AC 3.15A RY72 RY74 RY71 P/GRAY (LIVE) P/GRAY (NEUTRAL) GRN CA.
10 Schematic Diagrams 10-1 MAIN PCB.
FRIEDRICH AIR CONDITIONING CO. Post Office Box 1540 l San Antonio, T exas 78295-1540 4200 N. Pan Am Expressway l San Antonio, T exas 78218-5212 (210) 357-4400 l F AX (210) 357-4480 www .
Een belangrijk punt na aankoop van elk apparaat Friedrich SP05A10 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Friedrich SP05A10 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Friedrich SP05A10 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Friedrich SP05A10 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Friedrich SP05A10 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Friedrich SP05A10 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Friedrich SP05A10 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Friedrich SP05A10 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.