Gebruiksaanwijzing /service van het product V(E van de fabrikant Friedrich
Ga naar pagina of 44
VPSERVMN (4-05) MODELS V(E,H)A09K25*** V(E,H)A09K34*** V(E,H)A09K50*** V(E,H)A12K25*** V(E,H)A12K34*** V(E,H)A12K50*** V(E,H)A18K25*** V(E,H)A18K34*** V(E,H)A18K25*** V(E,H)A24K25*** V(E,H)A24K34*** V.
2 T able of Contents Intro ducti on ...................................................................... 3 V er t- I - Pak Mo del Numb er Identi fi catio n Guide .............. 4 Ser ial Numb er Ident ifi cati on Guide ............................
3 Introduction This service manual is designed to be used in conjunction with the installation manuals provided with each air conditioning system component. Air conditioning systems consist of BOTH an evaporator (indoor section) and a condenser (outdoor section) in one closed system, and a room thermostat.
4 PRODUCT LINE R = RAC P = PT AC E = EAC V = VP AK H = SPLIT SERIAL NUMBER Decade Manufactured J = 9 K = Not Used L = 0 MONTH MANUF ACTURED A = Jan D = Apr G = Jul K = Oct B = Feb E = May H = Aug L = .
5 VEA/ VHA9K -2 4K VEA09K VEA12K VEA18K VEA24K VHA09K VHA12K VHA18K VHA24K COOLING DA TA Cooling Btu/h 95 00 /9 30 0 1 1 80 0 /1150 0 18000/17800 24000 9500/9300 1 1800/1 1500 18000/17800 23500 Cooling Power (W) 8 80 10 93 20 70 25 26 90 5 1 1 2 4 20 70 24 74 EE R 10.
6 Mode l V(E,H)A 09 V(E,H)A 1 2 V(E,H)A 18 V(E,H)A24 Vo l t ag e ( V ) 23 0 / 208 23 0 / 208 23 0 / 208 23 0 / 208 Refri gera nt R- 22 R-22 R -22 R -22 Chassi s Width 23. 125" 23. 125" 23. 1 25" 23. 125" Chas si s Dep th 23. 125" 23.
7 * Height includes 2" high duct collar and 5/8" isolators under unit. **Normal V alue Dry Coil on High Speed @ .3" ESP . MODELS V(E,H)A09 K25 V(E,H)A09 K34 V(E,H)A09 K50 V(E,H)A12 K25 V(E,H)A12 K34 V(E,H)A12 K50 V(E,H)A18 K25 V(E,H)A18 K34 V(E,H)A18 K50 Cooling Cap.
8 A good understanding of the basic operation of the refrigeration system is essential for the service technician. Without this understanding, accurate troubleshooting of refrigeration system problems will be more diffi cult and time consuming, if not (in some cases) entirely impossible.
9 Electrical Rating T ables NOTE: Use copper conductors ONL Y Wire sizes are per NEC . Check local codes for overseas applications Recommended branch circuit wire sizes* Nameplate maximum circuit brea.
10 Heat Anticipators Heat anticipators are small resistance heaters (wired in series with the "W" circuit) and built into most electromechanical thermostats. Their purpose is to prevent wide swings in room temperature during system operation in the HEA TING mode.
11 T ypical Electr ical & Thermostat Wir ing Diagrams VEA / VHA 24K L1 L2 QUICK DISCONNECT HERM BLUE YELLOW GREEN WHITE RED CAPACITOR BROWN GREEN BROWN COMP WIRE HARNESS COMPRESSOR RED BLUE BLACK .
12 T ypical Electrical & Thermostat Wiring Diagrams G & H Suffi x N OT E: THE DIAGRAM ABOVE ILLUSTRA TES THE TYPICAL THERMOST A T WIRING AND 208 VOL T TRANSFORMER WIRING. SEE THE UNIT CONTROL P ANEL FOR THE ACTUAL UNIT WIRING DIAGRAM AND SCHEMA TIC.
13 T ypical Electrical & Thermostat Wiring Diagrams A – E Suffi x FOR 208 VOL T MODELS ONL Y : MOVE THE WHITE WIRE AS SHOWN BELOW ..
14 Indoor Blower - Air fl ow The cur rent V er t- I - Pak 9, 1 2, & 18 use a dual shaft, per manent split capaci tor , single speed motor to dr ive indoor blower and outdoor fan.
15 Checking External St atic Press ure The air f low through t he unit can be determine d by measuring the ex ternal static pres sure of the system, and consult ing the blower per formanc e data for the spec ifi c VER T - I- P A K. 1 . Set up to measure external st atic pressure at the supply and return air .
16 Ductwork Preparation Pull the fl ex duct tight. Extra fl ex duct slack can greatly increase static pressure Explanation of charts Chart A is the nominal dry coil VERT -I-P AK CFMs.
17 Method Of Charging The acceptable method for charging the V ert-I-Pak system is the Weighed in Charge Method. The weighed in charge method is applicable to all units.
18 Overcharged Refrigerant Systems Compressor amps will be near normal or higher . Noncondensables can also cause these symptoms. T o confi rm, remove some of the charge, if conditions improve, system may be overcharged. If conditions don’t improve, Noncondensables are indicated.
19 All units are e quipped with c apillar y tube metering devices. Checking for restricted capillary tubes. 1. Connect pressure gauges to unit. 2. Start the unit in the cooling mode. If after a few minutes of operation the pressures are normal, the check valve and the cooling capillary are not restricted.
20 Touch Test in Heating/Cooling Cycle The only defi nite indications t hat the slide is in the mid- po - sition is if all three tubes on the suc tion side of the valve are hot af ter a few minutes of running time. NOTE: A condit ion other than those illustrated above, and on page 1 9, indic ate that the rev ersing valve is not shifting properly .
21 WARNING DANGER OF BODIL Y INJUR Y OR DEA TH FROM ELECTRICAL SHOCK When working on high voltage equipment - turn the electrical power off before attaching test leads. Use test leads with alligator type clips - clip to terminals, turn power on, take reading - turn power off before removing leads.
22 Single Phase Resistance T est Remov e t he leads from the c ompressor ter minals and set the ohmmeter on the lowest scale ( R x 1 ). T ouch the leads of the ohmmeter from ter minals co mmon to star t ( " C " to "S " ). N ext, touch the leads of the ohmmeter from terminals c ommon to run ( " C " to "R " ).
23 F r om the supply line on a t ypical 23 0 volt circuit, a 1 15 v o lt potential exists from the " R " terminal to ground through a possible shor t in t he capacitor .
24 Emergency Heat Switch ( D efrost Thermost at) Continuit y C h eck Electric Heat Switch Operation (Heat Pumps Only) The electric heat switch is a dual function control and is shown on the wiring diagram as a defrost thermostat. It may be adjusted using a screwdriver .
25 VEA09K00 RT A ................... 80 0 0 491 0 ................... 28 VE A0 9 K00 RTB ................. 80 0 0 491 0 ................... 28 VE A0 9 K00 RTE ................. 80 0 0 491 0 ................... 28 VE A0 9 K00 RTG ................. 80 0 0 49 22 .
26 VE A 18K50 RTG ................. 8 0 0 0 492 0 ................... 32 VEA 1 8K50R TH .................. 8 0 0 0 4920 ................... 32 VE A 24K0 0RTH ................. 801 1050 0 .................... 37 VE A 24K 10RTH ................. 801 0 88 0 0 .
27 (A - D Suffi x only).
28 (A - D Suffi x only).
29 (A - D Suffi x only).
30.
31.
32.
33.
34.
35.
36.
37.
38.
39 9 - 1 8 ELECTRICAL TROUBL ESHOOTING CHART — COOLING Line V oltage available at fan speed switch (on models so equipped) NO COOLING Insure that Fuses are good and/or that Circuit Breakers are On C.
40 2- TON ELECTRIC AL TROUBLESHOOTING CHART — Cooling Line V oltage available at fan speed switch (on models so equipped) NO COOLING Insure that Fuses are good and/or that Circuit Breakers are On Co.
41 REFRIGERANT SYSTEM DIAGNOSIS COOLING TROUBLESHOOTING CHART — COOLING TROUBLESHOOTING CHART — HEA TING REFRIGERANT SYSTEM DIAGNOSIS HEA TING Low Suction Pressure High Suction Pressure Low Head P.
42 Replace Reversing V alve NO NO YES YES ELECTRICAL TROUBLESHOOTING CHART HEA T PUMP Reversing V alve Stuck YES Replace Solenoid Coil Is the Solenoid Coil Good? Is Line V oltage Present at Solenoid V alve? Is Selector Switch set for Heat? SYSTEM COOLS WHEN HEA TING IS DESIRED.
43.
VPSERVMN (4-05) Use Factory Certifi ed Parts. FRIEDRICH AIR CONDITIONING CO. P ost Office Box 1540 · San Antonio, T exas 78295-1540 4200 N. P an Am Expressway · San Antonio, T exas 78218-5212 (210) 357-4400 · F AX (210) 357-4480 www .friedrich.com Printed in the U.
Een belangrijk punt na aankoop van elk apparaat Friedrich V(E (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Friedrich V(E heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Friedrich V(E vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Friedrich V(E leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Friedrich V(E krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Friedrich V(E bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Friedrich V(E kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Friedrich V(E . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.