Gebruiksaanwijzing /service van het product 52 Series van de fabrikant Frymaster
Ga naar pagina of 39
PARTS LIST INCLUDED & DOMESTIC Dean, a member of the Commercial Food Equipm ent Service Association, recommends using CFESA Certified Technicians. Price: $8.
i Please read all sections of this manual and retain for future reference. Installation, maintenance, and repairs s hould be performed by your Dean Factory Authorized Service Center. CAUTION Do not store or use gasoline or other flammabl e vapors and liquids in the vicinity of this or any other cooking appliance.
ii SUPER RUNNER 52 SER IES GAS FRYERS TABLE OF CONTENTS Page # 1. INTRODUCTION 1-1 2. IMPORTANT INFORMATION 2-1 3. INSTALLATION INSTRUCTIONS 3-1 4. DAILY OPERATION 4-1 5.
1-1 SUPER RUNNER 52 SERIES GAS FRYERS CHAPTER 1: INTRODUCTION 1.1 Ordering Parts Customers may order parts directly from their local Authorized Parts Distributor. F or this address and phone number, contact your main tenance and repair center or call the factory.
1-2 1.3 Safety Information Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual, you will find notations en closed in double-bordered boxes similar to the ones below. CAUTION boxes contain information about actions or conditions that may cause or result in a malfunction of your system .
2-1 SUPER RUNNER 52 SERIES GAS FRYERS CHAPTER 2: IMPORTANT INFORMATION 2.1 General Dean Super Runner 52 Series gas fryers are energy- efficient, gas-fired units , design-certified by the CSA International (AGA/CGA), NSF International and m anufactured to their bas ic performance and application specifications.
2-2 2.4 Pre-Installation A. General : Only a licensed plumber should install any gas-fired equipment. 1. A manual gas shut-off valve must be installed in the gas supply line ahead of the fryers for safety and ease of future service. 2. Dean Super Runner Series gas fryers operate on millivolt, and do not require an externa l electric power supply.
2-3 2.6 Air Supply and Ventilation (cont.) C. A commercial, heavy-duty fryer must ven t its combustion wastes to the ou tside of the building. A deep-fat fryer must be installed under a powered exhaust hood, or an exhaust fan must be provided in the wall above the unit, as exhaust gas temperat ures are approximately 800-1000°F (427-538°C) .
2-4 2.7 Receiving and Unpacking Equipment (cont.) C. Move the fryer to th e location of in stallation and install legs and/or cas ters as described in Chapter 3.2. D. Remove all plastic skin from sides, front, and doors of the unit. Failure to do this will melt the plastic and make it very difficult to remove later.
3-1 SUPER RUNNER 52 SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3.1 Installing the Fryer A. Initial Installation: If installed with legs, do not push against the fryer’s side to adjust its position. Use a pallet or lift jack to lift the fryer slightly and pl ace it where it is to be installed.
3-2 3.2 Leg and Caster Installation (cont.) B. Leg and Rigid Caster Installation 1. Remove unit from pallet. 2. Carefully raise unit with forklift, pallet jack, or other steady means.
3-3 3.3 Leveling the Fryer (cont.) Rigid Casters (Only) 1. Install the rigid casters on the fryer rear channel only. Legs must be installed on the front channel. 2. There are no level adjustm ents for the rigid casters. B. If the floor is uneven or has a decided slope , place the fryer on a smooth platform.
3-4 3.3 Leveling the Fryer (cont.) NOTE: The installation must be inspected after it is complete to ensure it meets the inte nt of these instructions. The on-site supervisor and/ or operator(s) should be informed that the appliance is installed with restraints.
3-5 3.4 Gas Connections (cont.) The gas supply (service) line must be the same size or greater than the fryer inlet line. Super Runner 52-Series gas fryers are equipped with a 3/4" (19 mm) male ISO 7.1 inlet. The gas supply line m ust be sized to accommodate all gas-fired e quipment connected to that gas supply .
3-6 3.4 Gas Connections (cont.) Regulating Gas Pressure The fryer and shut-off valve must be disconnected from the gas suppl y during any pressu re testing of the system. External gas regulators are not nor mally required on this fryer. A safety control valve protects the fryer against pressure fluc tuations.
3-7 3.4 Gas Connections (cont.) D. Orifices : The fryer can be configured to operate on any available gas. The correct safety control valve, appropriate gas orifices, and pilot burner are in stalled at the factory.
3-8 3.4 Gas Connections (cont.) F. After hook up, bleed the gas line of air to ensure that the pilot light will ignite quickly and evenly. CAUTION Qualified personnel MUST perform any adaptation, modi fication, or gas conversion, if required. Failure to use qualified pe rsonnel will void the Dean warranty.
3-9 3.6 Gas Inputs (cont.) C. Adjustments for different gases are as follows: Gases and Gas Supply Pressure* G20 20 mbar G25 25 mbar G31 37 mbar Injector Diameter 2.
3-10 3.7 Gas Conversion: Procedures (cont.) When converting from G20 (20 mbar) to G25 (25 m ba r), or vice-versa, or G31 (37 mbar) to G31 (50 mbar), the following procedures apply: ♦ Check pilot-adjustment a nd adjust as necessary. ♦ Other adjustments are not necess ary.
3-11 3.7 Gas Conversion: Procedures (cont.) Vessel Assem bly Gas Valve Manifold Support Bracket Gas Burner See De tail A Pressure Test Spigot Orif ice Temperature Control Gas Manifold Assem bly 1/2—3/4 Reducer Bushi ng Burner Gas Manifold Burner/Orifi ce Location Detail A Orif ice 1.
3-12 3.8 Gas Conversion Kits (cont.) SR52G Propane to Natural Gas Components QTY REF DESCRIPTION 1 TJ024 Pilot orifice 5 14-0067-1 Burner orifice, #39 (diameter: 2.
4-1 SUPER RUNNER 52 SERIES GAS FRYERS CHAPTER 4: DAILY OPERATION 4.1 Initial Startup New units are wiped clean with solvents at the factory to remove any visible signs of dirt, oil, grease, etc., remaining from the manufacturing process, then coated lightly with oil.
4-2 4.2.1 Pilot Lighting Pro cedures, Domestic (non-CE) WARNING When checking for burner ignition or perf ormance, do not get too close to the burners. Slow ignition can cause possi ble flashback, incr easing the potential for facial and body burns. Light or re-light the pilot as follows: 1.
4-3 4.2.2 Pilot Lighting Procedures, CE Ensure that the following steps are done in sequence before lighting or re-lighting the pilot: 1. Turn off the manual shut-off valve on the incoming service line. 2. Turn the operating thermostat "OFF".
4-4 4.3 Boil-Out Procedure 1. Empty fry vessel and pour in cleanin g solution concentrate. Add water to the lower OIL LEVEL line scribed on the vessel back. 2. Set the operating thermostat-dial/temperature controller to 219°F (104°C), just above that of boiling water.
4-5 4.4 Final Preparation WARNING NEVER set a complete block of solid shortening on top of heating tubes. To do so will damage the heating tubes and fry vessel, and void the w arranty. 1. When using a liquid shortening (cooking oil), fill the fryer to the lower OIL LEVEL line scribed into the back of the fryer vessel.
4-6 4.6 Opening: Beginning the Work Da y At the beginning of each work day, always check the fryer to ensure: 1. The combination or main gas valve is "OFF". 2. Fry vessel is filled with liquid oil to the bottom OIL LEVEL line sc ribed into the r ear wall of the fry vessel tank.
4-7 4.7 Filtering Basics (cont.) Basic rules of filtering are: e The shortening should be filtered at least dail y o r even more frequently if cooking is heavy. Filtering ensures long shortening life, better tasting food and minimizes flavors being transferred from batch to batch.
5-1 SUPER RUNNER 52 SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5.1 General All food service equipment works better and lasts l onger when maintained pr operly and kept clean. Cooking equipment is no exception. The fryer shoul d be kept clean during the working day and thoroughly cleaned at each day’s end.
5-2 5.1.4 Stainless Steel Care WARNING DO NOT let water splash into the tank of h o t oil. It will splatte r and can cause severe burns. All stainless steel fryer cabinet pa rts should be wiped regularly with hot, soapy water during the day, and with a liquid cleanser designed for stainless steel at the en d of each day.
6-1 SUPER RUNNER 52 SERIES GAS FRYERS CHAPTER 6: TROUBLESHOOTING 6.1 General CAUTION This appliance may have more than one po wer supply connection point. Disconnect all power cords before servicing. The problems and possible solutions covere d are those most commonly encountered.
6-2 6.2 Pilot Burner Malfunction (cont.) C. Pilot flame of proper size, but is unstable. Flame wavers and does not envelop the thermocouple completely at all tim es. 1. Check for drafts that might be caused by air conditioning equipment or m ake-up air apparatus.
6-3 6.3 Main Burner Malfunction (cont.) D. Fryer will not reach the temperatur e setting and/or runs erratically. 1. Incorrect location of sensor probe or defective temperature sensor. 2. Loose wiring/wire connection E. Fryer shortening temperature ca nnot be controlled; fryer runs at high-lim it temperature.
6-4 6.4 Millivolt Wiring Diagrams 6.4.1 All Units (Except Australia) Combination Gas Valve High-Limit Operating Thermostat Whit e Red Black Red Red Black Thermopile 6.
7-1 SUPER RUNNER 52 SERIES GAS FRYERS CHAPTER 7: PARTS LIST 7.1 Super Runner 52 Primary Components 1 4 - 0 0 0 1 - 1 1 4 - 0 0 0 1 - 2 1 4 - 0 0 0 1 - 2 1 4 - 0 0 0 1 - 3 26 21 8 9 3 4 7 16 34 17 15 2.
7-2 7.1 Super Runner 52 Primary Components (cont.) ITEM PART # COMPONENT 1 50076-1 Vessel Weld Assembly M/S (823-3530 SM50) * 50076-2 Vessel Weld Assembly S/S (823-3329 SM50) 2 823-3618 Gas Manifold (Weld Assembly) 3 810-2048 Orifice For Natural Gas [#39 (2.
7-3 7.2 Super Runner 52 Gas Valves and Related Components, Domestic, CE and Australia 1a 2 3 5 6 7 4 16 15 14 12 9 8 13 10 11 1b.
7-4 7.2 Super Runner 52 Gas Valves and Related Components, Domestic, CE and Australia (cont.) ITEM PART # COMPONENT 1a 810-2036 Gas Valve, Millivolt, Natural Gas (Domestic Only) * 807-3549 Gas Valve, .
Dean, 8700 Line Avenue, Shreveport, Louisiana 71135 TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 (Tech Support) 1-318-219-7135 Price: $6.00 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1-800-551-8633.
Een belangrijk punt na aankoop van elk apparaat Frymaster 52 Series (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Frymaster 52 Series heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Frymaster 52 Series vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Frymaster 52 Series leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Frymaster 52 Series krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Frymaster 52 Series bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Frymaster 52 Series kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Frymaster 52 Series . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.