Frymaster, a member of the Co mmercial Food Eq uipment Service Asso ciation, recomm ends using CFESA Certified Tec hnicians. 24-Hour Service Hotline 1-800-551-8633 Price: $10.
Please read all sections of this manual and retain for future reference. NOTICE This appliance is intended for professional use only and is to be operated by qualified personnel only. A Frymaster and Dean Factory Authorized Service Center (FASC) or other qualified professional should perform installation, maintenance, and repairs.
DANGER Adequate means must be provided to limit the movement of this appliance without depending upon the gas line connection. Single fryers equipped with legs must be stabilized by installing anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains.
YSCFHC18G Cool Zone Gas Fryers INSTALLATION & OPERATION MANUAL TABLE OF CONTENTS Page # 1. INTRODUCTION 1-1 2. IMPORTANT INFORMATION 2-1 3. INSTALLATION INSTRUCTIONS 3-1 4.
YSCFHC18G HIGH EFFI CIENCY COOL ZONE SERIES GAS FRYERS CHAPTER 1: INTRODUCTION 1-1 1.1 After Purchase In order to improve service, have the following chart filled in by the Frymaster authorized service technician who installed this equipment. Authorized Service Technician/ASA Address Telephone/Fax Model Number Serial Number Gas Type 1.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 1: INTRODUCTION 1-2 1.3 Service Information Call the Frymaster Service Hotline, 1-800-551-8633, for the location of your nearest factory authorized service center (ASA).
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 1: INTRODUCTION 1-3 1.5 Safety Information (cont.) DANGER DANGER boxes contain information about actions or conditions, which may cau se or result in injury to personnel , may cause dam age to your system, and/or cause your system to malfunction.
YSCFHC18G HIGH EFFI CIENCY COOL ZONE SERIES GAS FRYERS CHAPTER 2: IMPORTANT INFORMATION 2-1 2.1 Receiving and Unpacking Equipment A. Check that the container is uprigh t. Use an outward prying m otion - no hammering - to remove the carton. Unpack the fryer carefully and rem ove all accessories from the carton.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 2: IMPORTANT INFORMATION 2-2 2.3 Principles of Operation The incoming gas flows through ori fices and is mixed with air in the burners to create the correct ratio for proper combustion. The mixture is ignited at the front end of each heat tube by the pilot light.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 2: IMPORTANT INFORMATION 2-3 2.5 Pre-Installation (cont.) DANGER This appliance must be installed with su fficient ventilation to prevent the occurrence of unacceptable concentrations of substan ces harmful to the health of personnel in the room in which it is installed.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 2: IMPORTANT INFORMATION 2-4 2.6 Air Supply and Ventilation DANGER Do not connect this appliance to the gas supply before reviewing each step in this section.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 2: IMPORTANT INFORMATION 2-5 2.8 Restraining the Fryer DANGER No structural material on the fryer shoul d be altered or removed to accommodate placement of the fryer under a hood. Questi ons? Call the Frymaster Dean Service Hotline at 1-800-551-8633.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 2: IMPORTANT INFORMATION 2-6 DANGER Hot oil can cause severe burns. Avoid contact . Under all circumstances, oil must be removed from the fryer before attempting to move it to avoid oil spills, falls and severe burns.
YSCFHC18G HIGH EFFI CIENCY COOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3-1 3.1 Installing the Fryer Qualified, licensed, authorized installat ion or s ervice personnel only (as defined in Section 1.6) should perform the following: 1.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3-2 3.2 Leg and Caster Installation (cont.) 2. When positioning the fryer, gently lower it into position to prevent undue strain to the legs and internal mounting hardware.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3-3 3.3 Leveling the Fryer (cont.) • Legs (Only) 1. Adjust leg height with an adjustable or 1 1 / 16 -inch (27-mm) open-end wrench by turning the hex bullet on the bottom of the leg.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3-4 3.3 Leveling the Fryer (cont.) ANSI Z83.11/11a-(Latest Edition) requires a fry er be restrained to prevent tipping when installed in order to avoid the splashing of ho t liquid.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3-5 3.4 Gas Connections (cont.) DANGER "Dry-firing" your unit will cause damage to the frypot and can cause a fire. Before firing the unit, always ensure that melted shortening, cook ing oil, or water is in the frypot.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3-6 3.4 Gas Connections (cont.) A. Manifold Pressure: Your local service technician shoul d check the manifold pressure with a man ome ter . 1. Check the rating plate for manifold gas pressu res.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3-7 3.4 Gas Connections (cont.) 2. For an appliance equipped with casters, the installation shall be ma de with a connector that complies with the Standard for C onnectors for Movable Gas Appliances, ANSI Z21.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3-8 3.6 Gas Conversion: Procedures DANGER This appliance was configured at the factory for a specific type of gas. Converting from one gas type to another requires th e installation of specific gas-conversion components.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3-9 3.7 Electrical Connections DANGER This fryer is equipped with a three-pr ong (grounding) plug for protection against electrical shock and must be plugged directly into a pr operly grounded, three-prong receptacle.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3-10 3.8 Safety Switches (cont.) B. Other Fryer/Filter Switches 1. Drain Valve Microswitch: The computer will display DRAIN OPEN when the drain valve is opened.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3-11 3.8 Safety Switches (cont.) C. Filtering: Drain Valve and Oil Return Handles 1. Drain Valve Handle: RED HANDLE. Push the red handle (located in the fryer cabinet) to the right to open the drain valve when filtering.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3-12 3.9 Initial Cleaning Before Startup New units are wiped clean with solv ents at the fact ory to remove any visible signs of dirt, oil, and grease remaining from the m anufacturing process.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3-13 3.10 Final Preparation (cont.) NOTE: If the float s witch is blocked in "down posi tion" w ith solid shortening, the fryer w ill not heat.
YSCFHC18G HIGH EFFI CIENCY COOL ZONE SERIES GAS FRYERS CHAPTER 4: DAILY OPERATION 4-1 4.1 General Use 1. At opening, always check that the powe r switch and the computer are OFF. 2. For consistent quality product, convenience, and long-term sa vings, use a high-quality liquid shortening.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 4: DAILY OPERATION 4-2 2. KFC-1 Cooking Computer: Turn the computer ON and ensure at least on e LED is lit above a product button (1-9). Select a cooking progr am as described in the KF C-1 SMS Cooking Computer User Guide.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 4: DAILY OPERATION 4-3 4.3 Filtering DANGER When filtering, never leave the filter unattended. The filter ed oil is at or near 350°F (177°C). Ensure all hoses are connected properly and drain handles are in their proper position prior to operating any switches or valves.
YSCFHC18G HIGH EFFI CIENCY COOL ZONE SERIES GAS FRYERS CHAPTER 5: FILTRATION 5-1 5.1 General WARNING The on-site supervisor is responsible for ensuring that operators are made a ware of the inherent hazards of operating a hot oil filtering system, particularly the aspects of oil filtration, draining, and cleaning procedures.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 5: FILTRATION 5-2 5.2 Filter Preparation (cont.) 1. Put on protective gear/gloves. Pull the f ilter pa n o ut of the filter cabinet. R emove cover. 2. Remove crumb screen. If crumbs are present in the crumb screen, empty the screen into a fireproof container.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 5: FILTRATION 5-3 5. Remove the filter scre en from the bottom of the pan. 6. Thoroughly clean the pan and all pan components as described for the crumb screen (Step 2 ). 7. Inspect the pickup tube a nd ensure vent hole is open and free of shortening/debris.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 5: FILTRATION 5-4 9. Reinstall the hold-down ring. Ensure filter paper is properly aligned under the hold-down ring. Press the filter paper into place with the hold-down ring, ensuring the paper laps against the walls of the filter pan.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 5: FILTRATION 5-5 DANGER Al wa y s e ns u r e t h at t h e o ve r - the-top oil return faucet is located over the frypot or an appropriate container before activating the o ver-the-top oil return system.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 5: FILTRATION 5-6 5.3 Filter Operations (cont.) 2. Remove the support grid from the frypot using the clean-out rod. Stir the oil with the L-shaped Teflon brush to suspend debris prior to draining.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 5: FILTRATION 5-7 Use the L-shaped brush to loosen debris as oil drains from the frypot. 5.3 Filter Operations (cont.) 4. Use the L-shaped brush to scrub the frypot, and to assist in sediment removal.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 5: FILTRATION 5-8 5.3 Filter Operations (cont.) 6. Close the red drain valve by pushing the handle to the right until it stops. The fryer will not operate unless the computer senses a closed drain microsw itch circuit.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 5: FILTRATION 5-9 9. Repeat Steps 1 and 2 in Secti on 5.2. Remove crumb screen and empty debris into a fireproof container. If possible, wash all filter pan com ponents in hot, soapy water.
YSCFHC18G HIGH EFFI CIENCY COOL ZONE SERIES GAS FRYERS CHAPTER 6: PREVENTATIVE MAINTENANCE 6-1 Well-maintained equipment operates more efficiently and lasts longer.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 6: PREVENTATIVE MAINTENANCE 6-2 6.3 Periodic/Annual This appliance should be inspecte d and adjusted period ically by qualified serv ice personnel as part of a regular kitchen maintenance program.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 6: PREVENTATIVE MAINTENANCE 6-3 6.3 Periodic/ Annual (cont.) Check filtration system integrity as follows: • With the filter pan empty, place each oil return handle in the OPEN position, one at a time.
YSCFHC18G HIGH EFFI CIENCY COOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7-1 7.1 Introduction This section provides an easy reference guide to some of the common problems that m ay occur during the operation of this equipment.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7-2 7.2 Fryer Troubleshooting For FAST-equipped fryers, consult the FAST cont roller manual. These steps apply to the KFC-1 SMS computer only. 7.2.1 Computer fails to turn ON when ON/OFF button is pressed.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7-3 7.2 Fryer Troubleshooting (cont.) 7.2.4 Frypot temperature differs from the computer setpoint temperature.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7-4 7.2 Fryer Troubleshooting (cont.) Frypot Front High-Limit Probe Temperature Probe No: Ensure the probe tip is ⅛ " from the top of the burner tubes (see illustration).
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7-5 7.2 Fryer Troubleshooting (cont.) 7.2.5 DRAIN OPEN message remains after closing drain valve. 1. KFC-1 SMS computer was turned OFF while draining frypot. 2. Close drain valve.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7-6 Fryer Troubleshooting (cont.) 7.2.7 Main burner malfunctions. A. Main burner will not ignite; no gas is present at main burner. 1. Check that float switch is not stuck in the "down" position.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7-7 7.3 Filtration System Troubleshooting Pump won' t start. • Return valve not fully opened . • Tripped circuit breaker . • Incorrect or no li ne voltage. • Failed or misadjus ted return microswitc h .
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7-8 7.4 Wiring Diagrams.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7-9 Fast-Equipped Control and Filter Circuit.
YSCFHC18G HIGH EFFICIENCY C OOL ZONE SERIES GAS FRYERS CHAPTER 7: TROUBLESHOOTING 7-10 KFC-1 Equipped Control and Filter Circuit.
Frymaster, L.L.C., 8700 Line Avenue, Shreveport, Louisiana 7110 6 TEL 1-318-865-1711 FAX (Parts) 1-31 8-688 -2200 FAX (Call Center) 1-318 -2 19-7135 Price: $10.
Een belangrijk punt na aankoop van elk apparaat Frymaster COOL ZONE SERIES *8196329* (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Frymaster COOL ZONE SERIES *8196329* heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Frymaster COOL ZONE SERIES *8196329* vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Frymaster COOL ZONE SERIES *8196329* leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Frymaster COOL ZONE SERIES *8196329* krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Frymaster COOL ZONE SERIES *8196329* bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Frymaster COOL ZONE SERIES *8196329* kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Frymaster COOL ZONE SERIES *8196329* . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.