SE RVIS KVM Multi Platform USB Emulation Server Intelligent Switch for Multi Platform For I A and UNIX servers FS - 1004MU FS - 1008MU User ’s Manual FUJITSU COMPONENT LIMITED 050209.
1 1) This product and document are the c opyright of Fujitsu Component Limited. Any unauthorized reprinting, copying, republishing, or modifications to this product or document is prohibited by la w. 2) The details of this product and document are subject to revision without notice.
2 Table of Contents 1 INTRODUCTION ............................................................................................................................................3 1.1. CONVENTIONS .........................................................
3 1 Introduct ion Thank you for your purchase of this KVM Switch ( from here on, simply referred to as the "switch device"). This switch device is usab le with PC/ AT compatible computers and Sun workstations (hereafter referred to as "hosts" ) under multi - platform configur ations.
4 1.3. Safety Instructions Read the “Safety Instructions” before use to ensure proper use of this product. Safety Instructions contained in this section are written for the us er to avoid any damage to property or injury to self; please read the following carefull y.
5 may fail to function properly depending on the software used. l The PS/2 keyboard and mouse connectors are the same shape. Be sure the colors match to connect them correctl y . If they are forced in or connected inc orrectl y , the switch device may not only fun c tion improperly but also may malfunction.
6 1.5. Safety Precautions and Limited Warranty Information: Fujitsu’s Products are not designed for use in medical or life support appliances, devices, or systems where malfunction of a Product can reasonably be expected to result in a personal i njury.
7 2. Features l By connecting several hosts ( PC/ AT compatible computers or Sun workstations ) to this switch device, you can save a lot of space by using only one common master console rather than the s ituation of a console (monito r, keyboard and mouse) for each host that was previously required .
8 3. Component Names and Their Functions 3.1 Console P anel 1) 4) 3) 2) 5) 8 Port Console Panel 1) 4) 3) 2) 5) 4 Port Console Panel 1) POWER LED L ights up when the host is ON. And, flashes when internal power is low by disconnect an AC cord or blow an internal fuse.
9 3.2 Rear Panel 6) 7) 1 3 ) 5) 9) 8) 10 ) 11 ) 12 ) 8 Port Rea r Panel 14 ) 7) 5) 9) 8) 13 ) 10 ) 12 ) 11 ) 4 Port Rear Panel 6) Power cable connector Connect to a 100 to 240V AC electric outlet.
10 3.3 DI P Switch Settings The factory default settings are as follows: 1 2 3 4 5 6 7 8 ON OFF (*Note: the indicates the switch position) DIP Switch Functions SW Function ON state / OFF state 1 Hot K.
11.
12 4. Installation Procedure (Rack Setup) 1. Remove the four flathead screws from the left and right sides of the switch device's console panel. 2. Remove the console panel from the switch device, and attach t he rack mount bracket (small) to it .
13 5. Setup 5.1. Getting started Set the DIP switches to match your chosen environment. Then confirm that the power cable for each host is plugged into an electric outlet and that the power is off.
14 3) After each host and switch device have been connected, connect the keyboard, mouse, and monitor to the [CONSOLE] connector s on the switch device . 4) Attach switch device's AC power cable and then plug it into an electric outlet. 5) After confirming that the connections have been made correctl y , start up the attached host s .
15 4) After each host and switching device have been connected, connect the keyboard, mouse, and monitor to the [CONSOLE] connector s on the ( master ) switch device . 5) Attach sw itch device's AC power cable and then plug it into an electric outlet.
16 6. Operation (Host selection) At the beginning, fir st powered up host is selected automaticall y . And if some hosts powered up at the same time, a host which connected lower port No. is selected. Also, when the power to a host is turned off while it is selected, the status is preserved.
17 6.2.1. Hot Key Mode A Press Ctrl, Alt, Shift on ce or press the Scroll Lock key twice to go into the H ot Key Mode and the following OSD screen is displayed. Example OSD Screen (probably different to actual screen) a) Screen Details 1.) Center - left of screen (black background) shows the state of the (master) switch device ports.
18 8.) If a cascade - connected master channel or any slave channel is selected, while the <Shift> key is pressed the OSD screen switches from “ 3 - character master/14 - character slave ” mode back to “ 14 - character master/5 - character slave ” mode.
19 [ Switching Via Mouse ] The mouse may also be used to control the OSD (instead of the keyboard): 1). Scroll the mouse up & down to select a host (channel) on the left side of the OSD. 2). If a cascade - connected channel is selected, the state of the selected slave device is shown on the right side of the OSD.
20 C) Setting/Changing Host Names 1). Select the host name to be set/changed using the cursor keys, exactly as if switching. 2). Press the < T ab> ke y. 3). The selected name turns yello w, with a single black on yellow characte r. 4). Use the keyboard to enter the desired name, then press the <Enter> key to confirm it.
21 6.2.2. Hot Key Mode B Press the <Ctrl> key twice to go into the H ot Key Mode and the following OSD screen appear in the upper - left of the screen. a) Screen Details 1). Selected host name is shown in the OSD in the upper left of the screen.
22 6.4. EDID Setting Mode After pressing the <Ctrl>+<Alt>+<Shift> keys or double pressing the <Scroll Lock> to activate the Hot Key Mode A, pressing the <N> key changes the display to switch to the Customer Mode: The top line accesses the ED ID Setting Mode.
23 We recommend a noninterlaced video signal for the on screen displa y . (Howeve r, it is possible to display an interlaced signal with a resolution of 1152 x 86 4, 1280 x 1024, or 1600 x 1200. However at resolution s lower than this and the display may extend beyond the edges of the screen.
24 7. Specifications Item Specification Product ID ( Model) FS - 1004MU (KVM switch) FS - 1008MU (KVM Switch) Number of Connected Host Devices Max. 4 (more if connections are cascaded) Max.
25 8. Optional Accessories ( Sold separately) l KVM Special Cables Item Product ID Remark Combined Keyboard + Mouse + Monitor Cable (1.8m) NC14000 - B602 NC14000 - B102 NC14000 - B202 PS/2 cable (this cable may be used for cascade connections) USB cable Sun cable Combined Keyboard + Mouse + Monitor Cable (3.
26 9. Troubleshooting Symptom Cause Action The AC cord is not connected to the electric outlet or to the switch device . Connect the AC cord. The AC power is off. Turn on the AC powe r. The PO WER LED is flashi ng. The internal power fuse has blown. Contact the place of purchase or the support cente r.
27 n Ke y layout diagram 1 (ASCII keyboard for PC/AT compatible machines) (1) When connecting to a PC/AT compatible machine (2) When connecting to a Sun workstation Ctrl ^ - * .
28 n Ke y la yout diagram 2 (ASCII keyboard for Sun ) (1) When connecting to a Sun workstation (2) When connecting to a PC/AT compatible machine + - - + Caps Lock Tab .
29 n Appendix: Host name record sheets Record a list of the names of the hosts that attached to your switch device. Master Unit NO. NAME 1 2 3 4 5 6 7 8 Slave Unit Port.1 NO. NAME 1 2 3 4 5 6 7 8 Slave Unit Port.5 NO. NAME 1 2 3 4 5 6 7 8 Slave Unit Port.
30 Declaration of Conformity Model Number : FS - 1004MU, FS - 1008MU Trade Name : KVM Switch Responsible party : FUJITSU CO M PONENT AMERICA, INC. Address : 250 East Car ibbean Drive, Sunnyvale,CA94089 T elephone number : (408) 745 - 4900 This device complies with Part 15 of the FCC Rules.
31 This manual is made of recycled pape r..
Een belangrijk punt na aankoop van elk apparaat Fujitsu FS-1004MU (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Fujitsu FS-1004MU heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Fujitsu FS-1004MU vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Fujitsu FS-1004MU leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Fujitsu FS-1004MU krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Fujitsu FS-1004MU bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Fujitsu FS-1004MU kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Fujitsu FS-1004MU . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.