Technical manual System board D1859 (Econel 50) English reliabilit y 2.
Are there ... ... any technical problems or ot her questions y ou need clarified? Please contact: ● your sales partner ● your sales outlet ● our hotline for customers who have purchased the system board as a single delivery unit: +49(0) 180 3777 005 The latest information and updates (e.
Intel, Pentium and Celeron are register ed trademarks of Intel Corporation, USA. Microsoft, MS, MS-DOS and Windows are regist ered trademarks of Microsoft Corporation. PS/2 and OS/2 Warp are registered trademarks of International Business Machines, Inc.
.
D1859 (Econel 50) Contents System board D1859 ............................................................................................................. ............. 1 Notational conventions ........................................................
.
D1859 (Econel 50) 1 System board D1859 Your sy stem board is available in different c onfiguration levels. Depending on the configuration chosen, some of the hardware components descri bed may not be available on y our system board.
Important notes 2 D1859 (Econel 50) Important notes With the system board installed y ou must open t he system to access the system board. How to dismantle and reassemble the system is descr ibed in the operating manual accompany ing the system. Connecting cables for peripherals must be adequately shielded to avoid interference.
List of features List of features Onboard features D1859-A Chipset Intel 925 Board size ATX VGA Audio / 8-channel / S/PDIF 5.1 / - / Buzzer / int. Speaker Support - / LAN 1 Gbit / 100 Mbit / 10 Mbit / / LAN ASF / AOL / WOL / Boot / - / / Serial ATA / ATA / RAID / / FireWire TM - USB 2.
List of features 4 D1859 (Econel 50) Internal ports (continued) D1859-A S/PDIF 5.1 (digital Audio)* OUT / IN - / - Audio Input - Front panel Audio (headphone, microphone, AC97) - IEEE 1394 connector* (FireWire TM )- USB Ports* (2.
Brief instructions on installing system board Brief instructions on installing system board If you have purchased a separate sy stem board, you c an install the system board in y our system in accordance with the following brief instructions.
Brief instructions on installing system board 6 D1859 (Econel 50) ► Should no suitable connection field be provided in the case, then you must install the connection field (1) provided. Ensure the plate is aligned properly so that the connections are suitable for the system board later.
D1859 (Econel 50) 7 Interfaces and connectors PCI 2 PCI 3 PCI 5 PCI 4 PCI Ex pr ess x1 PCI Ex pr ess x8 PCI 1 slot 1 slot 3 slot 4 slot 2 Chan nel B Channel A 1 2 3 4 5 6 7 8 16 14 13 12 11 10 9 BI O .
External ports 8 D1859 (Econel 50) External ports 13 4 5 2 6 7 8 1 PS/2 mouse port 5 VGA port 2 Parallel port/printer 6 S erial interface COM1 3 LAN connector (10/100/1000 Mbit/s) 7 USB1 connector 4 USB0 connector 8 PS/2 keyboard board LAN connector The system board is optionally equipped with t he Broadcom BCM5751 LAN controller.
Internal ports and connectors D1859 (Econel 50) 9 Internal ports and connectors The positions of the internal por ts and connectors are shown on the Cover.
Pin assignment of internal ports 10 D1859 (Econel 50) Pin assignment of internal ports The pin assignment of some internal connecti ons is shown in English in the following. i Some of the following connectors may be optional! Front panel Watch the poling of the LEDs.
Pin assignment of internal ports D1859 (Econel 50) 11 IDE/ATA interface 1 2 Pin Signal Pin Signal 1 Reset drive (low asserted) 2 GND 3 Data 7 (high asserted) 4 Data 8 (high asserted) 5 Data 6 (high as.
Pin assignment of internal ports 12 D1859 (Econel 50) USB - dual channel 1 2 11 12 Pin Signal Pin Signal 1 Key 2 Chipcardreader on or not connected 3 VCC 1 or 3 4 VCC 2 or 4 5 Data negative 1 or 3 6 D.
Pin assignment of internal ports D1859 (Econel 50) 13 Floppy interface 1 Pin Signal Pin Signal 1 GND 18 Step DIR (low asserted) 2 FDHDIN (low asserted) 19 GND 3 GND 20 Step Pulse (low asserted) 4 not .
Pin assignment of internal ports 14 D1859 (Econel 50) LCD display 2 1 Pin Signal Pin Signal 1 SMB CLK 8 LAN Link Icon 2 GND 9 Harddisk Action Icon 3 SMB DATA 10 BMC Alert Icon 4 GND 11 Message Icon 5 .
Pin assignment of internal ports D1859 (Econel 50) 15 Pow er supply BTX (ATX compatible) 1 13 Pin Signal Pin Signal 1 +3.3 V (P3V3P) 13 +3.3 V (P3V3P) 2 +3.
Pin assignment of internal ports 16 D1859 (Econel 50) Pow er supply control (System monitoring) 1 Pin Signal 1 Pow er Guard Control 2 PS FAN Control 4 PS FAN Sense.
17 D1859 (Econel 50) Jumper settings The positions of the jumpers are shown on page "Cover". Setting via control-panel plug connector A C 1 2 1 2 B 1 2 Pin pair A inserted = Skipping system .
18 D1859 (Econel 50) Add-on modules / Upgrading ! Exit energy-saving mode, switch off the sy stem and remove the power plug from the mains outlet, before carrying out any of the procedures described in this chapter! Even when you have run dow n the device, parts of the device (e.
Add-on modules / Upgrading D1859 (Econel 50) 19 a ► Insert the new processor in the socket so that the marking of the processor is aligned with the marking on the socket (a). 1 2 3 ► Fold down the frame (1). ► Press the lever downward (2) until it is hooked in again (3).
Add-on modules / Upgrading 20 D1859 (Econel 50) Mounting heat sink i Use only the heat sink supplied with y our system! Be sure to use heat conducting material bet ween the processor and the heat sink. If a heat conducting pad (rubber-like foil) is al ready applied to the heat sink, then use it.
Add-on modules / Upgrading D1859 (Econel 50) 21 Upgrading main memory Technical data Technology: DDR2 400 / DDR2 533 unbuffered DIMM modules 184-Pin; 1.
Add-on modules / Upgrading 22 D1859 (Econel 50) Installing a memory module 2 2 ► Push the holders on each side of the memory slot outwards. ► Insert the memory module into the location (1). ► At the same time flip the lateral holders upw ards until the memory module snaps in place (2).
Add-on modules / Upgrading D1859 (Econel 50) 23 Adding PCI Express cards The PCI Express x8 slot is intended for graphi cs cards, and the PCI Express x1 slot for PCI Express x1 cards. Adding PCI cards Technical data: 32 bit / 33 MHz PCI slots 3.3 V supply voltage (PCI 2.
Add-on modules / Upgrading 24 D1859 (Econel 50) Multifunctional expansion cards or expansion cards w ith integrated PCI-PCI bridge: These expansion cards require up to four PCI interrupts: INT A, INT B, INT C, INT D. How many and which of these interrupts are used is specifi ed in the documentation provided with the card.
Add-on modules / Upgrading D1859 (Econel 50) 25 Replacing the lithium battery In order to permanently save the sy stem informati on, a lithium battery is installed to provide the CMOS-memory with a current. A corresponding erro r message notifies the user w hen the charge is too low or the battery is empty .
Add-on modules / Upgrading 26 D1859 (Econel 50) BIOS update When should a BIOS update be carried out? Fujitsu Siemens Computers makes new BIOS ver sions available to ensure compatibility to new operating systems, new softw are or new hardware. In addition, new BIOS functions can also be integrated.
Add-on modules / Upgrading D1859 (Econel 50) 27 BIOS Recovery - Recovering Sy stem BIOS i All BIOS settings are reset to the default values. ► Open the casing as described in the operating manual. ► On the system board set the jumper to the appropriate setting to restore the system BIOS (see chapter "Jumper settings").
Add-on modules / Upgrading 28 D1859 (Econel 50) Microcode Update What is a microcode update? As there are no drivers for processors, Intel offer s the possibility from the P6 family ( Pentium Pro) on to update the command set (microcode) of the processor.
Annex D1859 (Econel 50) 29 Annex System board Revision and BIOS Version System board Rev ision The revision status of the system board exactl y identifies w hich system board y ou have.
Annex 30 D1859 (Econel 50) Electrical Properties Loadability for connections and fuses i Make sure that the connected devices do not overload the connections.
Error messages D1859 (Econel 50) 31 Error messages This chapter contains error me ssages generated by the system board. Available CPUs do not support the same bus frequency - System halted! Memory typ.
Error messages 32 D1859 (Econel 50) DMA test failed EISA CMOS not writable Extended RAM Failed at offset: nnnn Extended RAM Failed at address line: nnnn Failing Bits: nnnn Fail-Safe Timer NMI failed M.
Error messages D1859 (Econel 50) 33 Keyboard error nn nn Stuck Key Release the key on the key board ( nn is the hexadecimal code for the key). Missing or invalid NVRAM token Switch the device off and on again. If the message is still displayed, please contact y our sales outlet or customer service centre.
Error messages 34 D1859 (Econel 50) System Management Configuration changed or Problem occurred A system fan or sy stem sensor has failed. Check the hardware operation. System timer error Switch the device off and on again. If the message is still displayed, please contact y our sales outlet or customer service centre.
35 D1859 (Econel 50) Glossary The technical terms and abbreviations given below represent only a selection of the full list of common technical terms and abbreviations. Not all technical terms and abbreviations listed here are valid for the described system board.
Inf orma tion on this doc umen t On Ap ril 1, 2009 , Fuj itsu be came the so le owner o f Fuj itsu Si emens Comp u- ters. This new subsi diar y of Fujitsu h as b een renam ed Fuj itsu T echnol og y So- lution s.
Een belangrijk punt na aankoop van elk apparaat Fujitsu RELIABILITY D1859 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Fujitsu RELIABILITY D1859 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Fujitsu RELIABILITY D1859 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Fujitsu RELIABILITY D1859 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Fujitsu RELIABILITY D1859 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Fujitsu RELIABILITY D1859 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Fujitsu RELIABILITY D1859 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Fujitsu RELIABILITY D1859 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.