GE Monogram ® Installation Instr uctions 36" Downdraft Gas Cooktops Models ZGU365.
CAUTION 2 Before you begin—Read these instr uctions completely and carefully . IMPORT ANT: Save these instr uctions for local inspector’s use. IMPORT ANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES. NOTE TO INST ALLER: Be sure to leave these instr uctions with the Consumer .
3 Models Available ZGU365 36" gas downdraft cooktops Design Infor mation G a s D owndraf t Co ok top These models are shipped for natural gas operation. They can be converted to liquid propane. (Order JXLP56 conversion kit.) These gas downdraft cooktops are equipped with an vent system which can be retracted when not in use.
4 Design Infor mation G a s D owndraf t Co ok top Advance Planning Clearances • The downdraft system with blower , motor and ductwork will occupy the cabinet below the cooktop.
5 Cut the Opening Cabinetr y/Ductwork G a s D owndraf t Co ok to p Measure carefully when cutting countertop. Make sure sides of opening are parallel and rear and front cuts are exactly perpendicular to sides. • The Monogram gas downdraft cooktop is designed to fit in a 36" or larger base cabinet.
6 Ductwork G a s D owndraf t Co ok top V enting Options • The downdraft vent is shipped with the discharge outlet pointing straight down and can be changed to the left or right side. • The blower outlet is sized for 3-1/2" x 10" and can be transitioned to 6" round.
7 Ductwork G a s D owndraf t Co ok top Duct Fittings T otal Equivalent Quantity Equivalent Duct Piece Dimensions Length* Used Length 1 ft. 6" round, (per foot straight length) 1 ft. 3 -1 ⁄ 4" x 10" (per foot straight length) 6" 90 ° elbow 15 ft.
8 Gas and Electrical Supply G a s D owndraf t Co ok top Gas supply: These cooktops are designed to operate on natural gas at 4" of water column pressure or on LP gas at 10" of water column pressure. – These cooktops are shipped from the factor y set for natural gas.
9 Installation G a s D owndraf t Co ok top Remove Packaging • Remove the shipping materials and the carton, set carton aside. The carton can be used as a pad when changing or adjusting vent direction. • Remove the plastic ties on both ends at the top of the vent.
10 Installation G a s D owndraf t Co ok top • Install the supplied pressure regulator and nipple in the gas line as close to the cooktop inlet as possible. Allowances for ventilation ducting may be necessar y . –Make sure the regulator is installed in the right direction.
11 Installation G a s D owndraf t Co ok to p Note: If the cooktop is installed into a 36" base cabinet, the pressure regulator MUST BE installed to the bottom of the cooktop before the cooktop is placed into the cabinet. • Remove packaging from the cooktop.
12 Installation G a s D owndraf t Coo k top 5 Electrical Connections Step • Connect the 3-pin plastic plug from the blower/motor assembly to the 3-pin plastic socket on the underside of the vent, next to the conduit. • Slide the metal cover over the connection and secure with screws.
13 Installation G a s D owndraf t Co ok top T o raise the vent, tur n the VENT knob to RAISE/LOWER. • Hold the knob until the vent begins to raise. – The vent will automatically stop when it is fully extended. • T ip filter into the opening and pull straight down so that the filter rests on slides.
14 JXRB57 Kit For Indoor Remote Blower Locations Tools and Materials required: • Pencil • Measuring tape • Drill with appropriate bits • Nut driver • Junction box • Wire nuts • Safety glasses • 3-1/4" x 10" to 6" round transition.
15 JXRB57 Kit For Indoor Remote Blower Locations • Remove the 4 nuts holding the blower to the mounting plate. One nut is hidden inside the outlet. Remove blower . • Remove the blower mounting plate. • Remove 2 screws along the bottom of the blower box which are visible once blower plate is removed.
16 4 Connect Electrical Step 3 Connect Ductwork Step JXRB57 Kit For Indoor Remote Blower Locations Duct Adapter Outlet Cover Downdraft • The downdraft plenum can discharge from either the right or left side. Select the side that provides the best alignment to ductwork extending to the blower assembly below .
17 JXBC57 Kit For Outdoor Remote Blower Locations Materials Required (not supplied) • Approved liquid tight service connections for use between the wire compartment on the base and inside the structure. • 7 wire nuts or other approved connectors. • Six 5/16" dia.
18 JXBC57 Kit For Outdoor Remote Blower Locations 2 Mark Mounting Location Step • The base is designed to be mounted to studs on 16" centers. Use the dimensions shown to deter mine the location of the ducting and wiring through the wall.
19 JXBC57 Kit For Outdoor Remote Blower Locations 3 (continued) Step • Remove the 4 nuts holding the blower to the mounting plate. One nut is hidden inside the outlet. Remove blower . • Remove the blower mounting plate. • Remove 2 screws along the bottom of the blower box which are visible once blower plate is removed.
20 JXBC57 Kit For Outdoor Remote Blower Locations 5 Connect Electrical Step • Use electrical cable and connectors that conform to local codes (14 gauge min. is recommended). Use a length to reach between the vent and the blower/motor location. • Attach the wire box removed from the blower conduit to the end of new wiaring.
21 Notes.
22 Notes.
23 Notes.
NOTE: While performing installations described in this book, safety glasses or goggles should be worn. T o obtain specific information concerning any Monogram product or service, call GE Answer Center ® consumer information service at 800.626.2000—any time, day or night.
Een belangrijk punt na aankoop van elk apparaat GE Monogram ZGU365 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen GE Monogram ZGU365 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens GE Monogram ZGU365 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding GE Monogram ZGU365 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over GE Monogram ZGU365 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van GE Monogram ZGU365 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de GE Monogram ZGU365 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met GE Monogram ZGU365 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.