User manual Digital Energy GT Series Rack-mount Uninterruptible Power Supply 1000-1500-3000 VA UL-version GE Consumer a nd Industrial – P ower Qualit y Digita l Energy ™ 701 E. 22 nd Street Suite 300 Telepho ne 800-637-1 738 Lombard, IL 60148 USA Website www.
OPM_GTU_19 X_1K0_3K0_X US_V014 1 GT-UL Series: User manua l 1.2 (US) Digital Energ y ™ GT Serie s g USER MANUAL Digital Energy™ GT Series Rack-mount Uninterr uptible Power Supply 1000 - 1500 - 300.
OPM_GTU_19 X_1K0_3K0_X US_V014 2 GT-UL Series: User manua l 1.2 (US) Digital Energ y ™ GT Serie s g CONTENTS 1 IMPORTANT SAFETY INST RUCTIONS ..................................... ......... 3 1.1 Save t hese inst ructi ons 1.2 General 1.3 Installatio n 1.
OPM_GTU_19 X_1K0_3K0_X US_V014 3 GT-UL Series: User manua l 1.2 (US) Digital Energ y ™ GT Serie s g 1.1 Save these inst ructions This manual contain s important instr uctions for the Digital Energy™ GT Series-UL UPS that should be f ollowed du ring installa tion and ma intenance of th e UPS and the batteries.
OPM_GTU_19 X_1K0_3K0_X US_V014 4 GT-UL Series: User manua l 1.2 (US) Digital Energ y ™ GT Serie s g 1.4 Batteries • NOTE : Servicing of batterie s should be performe d or supervised b y personne l knowledgeable of batter ies and the r equired pre caution s.
OPM_GTU_19 X_1K0_3K0_X US_V014 5 GT-UL Series: User manua l 1.2 (US) Digital Energ y ™ GT Serie s g 1.6 FCCIS Interference Statements 1kVA MODEL Federal Com munication s Commission Interferen ce Statemen t This equipment has been tested and found to comply with the limits for a Class B digi tal device, pursuant to P art 15 of the FCC Ru les.
OPM_GTU_19 X_1K0_3K0_X US_V014 6 GT-UL Series: User manua l 1.2 (US) Digital Energ y ™ GT Serie s g 2.1 Package contents The packi ng box cont ains a Digital Energy™ GT Series-UL UPS , an RS232 data cable, a CD ROM, two mounting brackets with screws and this manual .
OPM_GTU_19 X_1K0_3K0_X US_V014 7 GT-UL Series: User manua l 1.2 (US) Digital Energ y ™ GT Serie s g 2.4 Installation The unit should be insta lled by servic e personne l.
OPM_GTU_19 X_1K0_3K0_X US_V014 8 GT-UL Series: User manua l 1.2 (US) Digital Energ y ™ GT Serie s g 2.4.3 Connecting an e xternal battery pack 1. Befo re installation, check whether the nomin al voltage of batt ery pack is suitable for the UPS. The voltage s mentioned on the batt ery connectors should mat ch.
OPM_GTU_19 X_1K0_3K0_X US_V014 9 GT-UL Series: User manua l 1.2 (US) Digital Energ y ™ GT Serie s g 2.4.6 Connecting to the utility pow er supply 1000/1500V A: Use a suitable power cord, and plu g it into the inpu t socket (see f ig. 2.6) 2200/3000V A: The UPS is equipped wit h a fixed input power cor d.
OPM_GTU_19 X_1K0_3K0_X US_V014 10 GT-UL Series: User manual 1.2 (US) Digital Energ y ™ GT Serie s g 3.1 Operation Panel 1 Switch ‘I/TEST’ - Switches on the UPS - In ‘ ON-LINE’ mode i t start.
OPM_GTU_19 X_1K0_3K0_X US_V014 11 GT-UL Series: User manual 1.2 (US) Digital Energ y ™ GT Serie s g 3.2 Start-up 3.2.1 Start-u p, utility power avail able 1 Pu sh the ‘I /TEST’-butt on (1) and hold for 3 seconds until a short beep is heard. The bypass LED will short ly light up.
OPM_GTU_19 X_1K0_3K0_X US_V014 12 GT-UL Series: User manual 1.2 (US) Digital Energ y ™ GT Serie s g 3.3.4 Silencing the buzzer When the UPS is in ‘ON BATTERY’ mode the b uzzer can be tu rned on or off by pressing the ‘I/TEST’- button (1). 3.
OPM_GTU_19 X_1K0_3K0_X US_V014 13 GT-UL Series: User manual 1.2 (US) Digital Energ y ™ GT Serie s g 3.4.4 Bypass operation If the UPS is unab le to deliver the demanded output power due to ove rload or over-temp eratur e, the load is switched directly to the ut ility supp ly.
OPM_GTU_19 X_1K0_3K0_X US_V014 14 GT-UL Series: User manual 1.2 (US) Digital Energ y ™ GT Serie s g 4.1 Description The GT Series UPS is equipped with a communication s interface, providing RS 232 and dry contact prot ocols in one sub- D 9-pin female connector lo cated at the rear of the un it.
OPM_GTU_19 X_1K0_3K0_X US_V014 15 GT-UL Series: User manual 1.2 (US) Digital Energ y ™ GT Serie s g 4.2 RS232 The RS-232 co mmunicatio n port provi des the following functi ons: 1 - Monit oring char.
OPM_GTU_19 X_1K0_3K0_X US_V014 16 GT-UL Series: User manual 1.2 (US) Digital Energ y ™ GT Serie s g 4.4 SNMP Plug-i n Card (optional) SNMP (Simple Net work Managem ent Protoco l) is the most po pular protoc ol in the network. Via NMS (Network Manage ment Station) yo u can detect the statu s of all facilities in the networ k.
OPM_GTU_19 X_1K0_3K0_X US_V014 17 GT-UL Series: User manual 1.2 (US) Digital Energ y ™ GT Serie s g Apart from t he SNMP-opt ion described in 4.4 the fo llowing options are po ssible: 5.1 Extended Runtime Extended runt ime can be obt ained by co nnecting a sep arate batter y extension module to the UPS.
OPM_GTU_19 X_1K0_3K0_X US_V014 18 GT-UL Series: User manual 1.2 (US) Digital Energ y ™ GT Serie s g 6.3.2 Battery replacement procedure) 1.5kVA 1 Remove fro nt panel 2 Unscrew two bo lts of the 3 ba.
OPM_GTU_19 X_1K0_3K0_X US_V014 19 GT-UL Series: User manual 1.2 (US) Digital Energ y ™ GT Serie s g Whenever a malfunc tion occ urs, fi rst c heck exter nal fac tors (e. g. connec tions, temperature , humidity or load) to det ermine whether the problem is cau sed by the unit itself or by its environment .
OPM_GTU_19 X_1K0_3K0_X US_V014 20 GT-UL Series: User manual 1.2 (US) Digital Energ y ™ GT Serie s g GT Model 1000R UL 1500R UL 2200R UL 3000R UL Capacity 1kVA/800W 1.5kVA/1200W 2.kKVA/1600W 3kVA/2400W Rated Voltage 100V, 110V, 1 20V Voltage Rang e 80V~138V (ful l load); 65V~ 80V (70% load) Frequency 50Hz / 60Hz (± 4.
Een belangrijk punt na aankoop van elk apparaat GE Power Supply (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen GE Power Supply heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens GE Power Supply vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding GE Power Supply leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over GE Power Supply krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van GE Power Supply bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de GE Power Supply kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met GE Power Supply . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.