www .GEAppliances.com 49-7406 11-00 JR Operating Instructions Auto Changeover . . . . . . . . . .10 Day/Time Setting Mode . . . . .6 Default Mode . . . . . . . . . . . . . . .4 Fan Control . . . . . . . . . . . . . . .10 Hold and Temporary Override . .
2 Using your thermostat. The digital programmable series of thermostats offers an economical remote control solution for single-stage heat/cool and multi-stage heat pump applications. System selections include heat, cool, off or auto mode, as well as fan on or fan auto selections.
T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions 3 www .GEAppliances.com KEY FUNCTION ▲ • Increases data (time, temperature, etc.). • Press with ▼ to enter span setting mode. ▼ • Decreases data (time, temperature, etc.
4 T emperature Scale Selection ■ The temperature scale can be selected by the C/F dip switch inside the unit. Please refer to Figure 3 in the Installation Instructions for identification of the correct switch. ■ If C/F switch is set at “F,” the temperature scale after reset is Fahrenheit.
T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions 5 www .GEAppliances.com T ime Format ■ Time is displayed in AM/PM format. ■ AM/PM format is <AM|PM>hh:mm where the leading zero of the hour will be suppressed.
6 Using your thermostat. Hold and T emporary Override ■ Hold is the permanent bypass of program temperature setpoints. Manual release is required to return to active program mode. ■ Press HOLD/RETURN in NORMAL mode for hold. The current setpoint temperature will be used.
7 www .GEAppliances.com Programming Mode The RAK163P1 and RAK147P1 are capable of programming in either 5+2 or 7 day formats. The table below is the default program for both the heating and cooling programs. If nothing is changed, these will be the times and temperatures that are active.
8 Using your thermostat. Press PROGRAM from the NORMAL mode. The program time- hour will be flashing and the MORNING time period will be active. Press ▲ or ▼ to adjust time. To change programming days press DA Y/TIME button. The order of the day programming is: ■ Weekday Program (i.
T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions 9 www .GEAppliances.com Press PROGRAM again. The next program time period will be displayed. The order of the time periods within one day are: 1. Morning 2. Day 3.
10 Fan Control ■ If FAN AUTO is selected, the fan will cycle On/Off with the system. If FAN ON is selected, the Fan will be on all the time. Using your thermostat. LCD Backlight ■ LCD backlight is activated when any key is pressed. Any subsequent key press or switch change will extend the period.
Open the cover on the thermostat and insert a small coin or flat-bladed screwdriver in the slot on the top of the thermostat and twist 1/4 turn. Grasp the base from the side and remove from the thermostat.
12 Installation Instructions MOUNTING AND WIRING (CONT .) Connect the wires from the existing system to the thermostat terminals according to the wiring diagrams in Table 1 and Table 2. Push any excess wire back into the wall and seal the hole with putty or a caulking material to prevent drafts from affecting the ambient temperature of the sensor.
DIP SWITCH SWITCH SELECTION FUNCTION 1 ON DC V oltage: 24 VDC OFF AC V oltage: 24 V AC 2O N ° C OFF °F 3 ON Keypad locked OFF Keypad unlocked 4 ON Backlight Override. Backlight does not operate if this switch is on. OFF Backlight is operating. Anytime a button is pressed, the backlight display will turn on.
THERMOSTAT COVERED RAK163P1, RAK147P1 Power Requirements 18–30 V AC or VDC electronic thermostat for 5-wire 1H/1C systems (RAK163P1) and 6-wire 2H/1C systems (RAK147P1) T emperature Measurement Rang.
15 T roubleshooting tips… www .GEAppliances.com Save time and money! Review the chart on this page first and you may not need to call for service. Problem Possible Causes What T o Do No display/faint display Supply voltage not correct. • Using a voltmeter, check the supply voltage to the thermostat.
16 Notes. T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions.
General Electric Company Warranty Registration Department P.O. Box 32150 Louisville, KY 40232-2150 Please place in envelope and mail to: ✁ Cut here 17 Consumer Product Ownership Registration Important Mail Today! General Electric Company Louisville, Kentucky www.
18 T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions Notes..
19 Notes. T roubleshooting T ips Operating Instructions Safety Instructions Installation Instructions.
20 Thermostat W arranty . For The Period Of: GE Will Replace: One Y ear Full Replacement of the thermostat which fails due to a defect in materials or workmanship. From the date of the original purchase ■ Service trips to your location. ■ Improper installation.
Een belangrijk punt na aankoop van elk apparaat GE RAK147P1. RAL163P1 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen GE RAK147P1. RAL163P1 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens GE RAK147P1. RAL163P1 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding GE RAK147P1. RAL163P1 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over GE RAK147P1. RAL163P1 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van GE RAK147P1. RAL163P1 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de GE RAK147P1. RAL163P1 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met GE RAK147P1. RAL163P1 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.