Gebruiksaanwijzing /service van het product EXT-DVI-16416 van de fabrikant Gefen
Ga naar pagina of 51
www.gefen.com.
ASKING FOR ASSIST ANCE T echnical Support : T elephone (818) 772-9100 (800) 545-6900 Fax (818) 772-9120 T echnical Support Hours: 8:00 AM to 5:00 PM Monday thru Friday PST Write T o: Gefen, LLC c/o Customer Service 20600 Nordhoff St Chatsworth, CA 9131 1 www .
CONTENTS 1 Introduction 2 Operation Notes 3 Features 4 Panel Layout 5 Panel Descriptions 6 Connecting And Operating The 16x16 DVI Matrix 7 Front Panel Display 9 RMT -16416IR Remote Description 10 RMT .
1 Congratulations on your purchase of the 16x16 DVI Matrix. Y our complete satisfaction is very important to us. Gefen Gefen delivers innovative computer and electronic solutions that harness integration, extension, distribution and conversion technologies.
2 READ THESE NOTES BEFORE INST ALLING OR OPERA TING THE 16X16 DVI MA TRIX • The 16x16 DVI Matrix will not pass HDCP content. • There is no internal scaling in the 16x16 DVI Matrix. All of the attached monitors must be able to display the resolutions output by the source devices.
3 Features • Increases productivity by providing access to 16 displays from any 16 computers. • Web-based control switching • Maintains beautiful, sharp resolutions up to 1920x1200. • Serial RS-232 port for remote control via a computer or control automation device.
4 Front Panel Back Panel 4 3 P ANEL LA YOUT 5 2 1 7 8 6 9 10 11 12.
5 P ANEL DESCRIPTIONS 1 Main LCD Display This 2 line 16 character display will display status information and is also used to manage the display/source routes. 2 Control Buttons These buttons are used to navigate the functions of the 16x16 DVI Matrix.
6 How to Connect the 16x16 DVI Matrix 1. Connect up to 16 DVI source devices to the DVI inputs on the rear panel of the 16x16 DVI Matrix using DVI cables. 2. Connect up to 16 DVI capable display to the DVI outputs on the rear panel of the 16x16 DVI Matrix using DVI cables.
7 FRONT P ANEL DISPLA Y MAIN DISPLA Y The Main Display of the 16x16 DVI Matrix is a 16 character 2 line display . This display will show the standby screen and will also be used to aid in performing routing commands. After the Matrix has been turned on, the following screen will be displayed: This screen will display the company and product name.
8 FRONT P ANEL DISPLA Y ROUTING T o route sources to a display: Starting at the standby screen, press the SELECT button. The display selection screen will now be displayed: On this screen use the ◄ or ► buttons to select the desired display that will have a source routed to it in the next step.
9 1 2 1 LED Button Press Indicator This LED will activate momentarily upon each button press. This visual indicator is to inform the user that a command has been sent by the IR remote control. 2 Display and Source Selection Buttons These buttons will be used to send display and source selections to the 16x16 DVI Matrix.
10 IR Code Dip Switches Empty Battery Slot T o use the RMT -16416IR remote, remove the battery cover on the back of the remote to reveal the battery compartment. Insert the included battery into the open battery slot. The positive (+) side should be facing up.
11 Remote Channel 1: Default 1 2 Remote Channel 2: 1 2 Remote Channel 3: 1 2 Remote Channel 4: 1 2 Left: Picture of the opened rear battery compartment of the RMT -16416IR remote showing the exposed DIP Switch bank between the battery chambers.
12 Invoking Standby Mode T o place the 16x16 DVI Matrix into Stand-by mode, simultaneously press and hold the SELECT and CANCEL buttons for 5 seconds, then release.
13 EDID MANAGEMENT FEA TURE EDID. What is it and what is it used for? Under normal circumstances, a source device (digital and analog) will require information about a connected device/display to assess what resolutions and features are available.
14 RS-232 SERIAL CONTROL INTERF ACE What features are available via the RS-232 serial communications port? The GefenPRO 16x16 DVI Matrix can accept commands through the RS-232 serial communications port located on the rear panel. The current RS-232 control features are: • Switching/routing of inputs to outputs without the IR remote control.
15 RS-232 SERIAL CONTROL COMMANDS RS-232 Features RS-232 remote functions are used to control of this product’s features. Features include input to output routing, EDID storage, EDID management, etc.
16 RS-232 SERIAL CONTROL COMMANDS S Command The S command routes a single input to all 16 DVI outputs. Syntax: s param1 Parameters: param1 Input [0 - 16] Notes : Setting param1 to a value of 0 will place the matrix in one-to-one mode . This means that Input1 will be routed to Output1, Input2 will be routed to Output2, and so on.
17 RS-232 SERIAL CONTROL COMMANDS F Command The F command returns the state of pin 14 of the DVI inputs. Syntax: f Parameters: None Notes: “High” is returned if +5V is enabled on the DVI input. “Low” is returned if +5V is disabled on the DVI input.
18 RS-232 SERIAL CONTROL COMMANDS EDID Management Function Description #EDIDDSTOLO Read downstream EDID and stores into a Local EDID #EDIDDSTOBA Read downstream EDID and stores in EDID Bank #EDIDBA TO.
19 RS-232 SERIAL CONTROL COMMANDS #EDIDDSTOBA Function The #EDIDDSTOBA function reads the downstream EDID and stores it to a speci fi ed EDID bank. Syntax: #EDIDDSTOBA param1 param2 Parameters: param.
20 RS-232 SERIAL CONTROL COMMANDS #EDIDDETOLO Function The #EDIDDETOLO function stores the Default EDID in any Local EDID. Syntax : #EDIDDETOLO param1 param2 param3.
21 RS-232 SERIAL CONTROL COMMANDS #PRDSEDID Function The #PRDSEDID function reads the downstream EDID and sends it to the serial port. Syntax: #PRDSEDID param1 Parameters: param1 A downstream display [1 - 16] #PRLOEDID Function The #PRLOEDID function reads the local EDID of a speci fi ed input and spools it to the serial port.
22 RS-232 SERIAL CONTROL COMMANDS #PREDIDST Function The #PREDIDST function prints a table that contains details relating to the Local EDID source and the display name. Syntax: #PREDIDST Parameters : None #LOCKEDID Function The #LOCKEDID function secures the Local EDID and disables the automatic loading after power-up.
23 RS-232 SERIAL CONTROL COMMANDS IP Con fi guration Function Description #SIP ADD Speci fi es a new IP address #SNETMASK Speci fi es a new net mask #SGA TEWA Y Speci fi es the new gateway #SPORT .
24 RS-232 SERIAL CONTROL COMMANDS #SNETMASK Function The #SNETMASK function speci fi es a new net mask. Syntax: #SNETMASK param1 param2 param3 param4 Parameters: param1 IP address [0 - 255] param2 IP address [0 - 255] param3 IP address [0 - 255] param4 IP address [0 - 255] Notes: A reboot is required after using this function.
25 RS-232 SERIAL CONTROL COMMANDS #SPORT Function Speci fi es a new port. Syntax: #SPORT param1 Parameters: param1 Port [0 - 255] Notes: A reboot is required after using this function. #PRWEBADD Function Prints the current IP con fi guration on the screen.
26 RS-232 SERIAL CONTROL COMMANDS General Functions Function Description #F ADEF AUL T Reset Matrix to default settings #RMTIRADD Set the remote IR channel #MASKOUT Blanks selected outputs #ACTIVEBOLO.
27 RS-232 SERIAL CONTROL COMMANDS #MASKOUT Function The #MASKOUT function allows blanking of selected outputs. Syntax: #MASKOUT param1 param2 Parameters: param1 Output [1 - 16] param2 Masking state [0 - 1] V alue Meaning 0 Unmask 1 Mask Notes: The current masking state will be lost if the unit is rebooted or power is lost.
28 RS-232 SERIAL CONTROL COMMANDS #STBYMODE Function The #STBYMODE places the Matrix in stand-by mode. Stand-by mode reduces power consumption. Syntax: #STBYMODE param1 Parameters: param1 State [0 - 1] V alue Meaning 0 Disable stand-by mode 1 Enable stand-by mode #LOCKPOWER Function The #LOCKPOWER enables/disables the power lock state.
29 IP CONTROL - MAIN P AGE The 16x16 DVI Matrix supports IP based control via an IP Control. T o access this feature an IP address, subnet, gateway , and port need to be set on the 16x16 DVI Matrix ( Default IP: 192.168.0.70 Subnet: 255.255.255.0 Gateway: 192.
30 IP CONTROL - MANAGE EDID MANAGE EDID The Manage EDID page is used to see the status of the EDID saved in the LOCAL storage location for each input. This section has additional tabs for advanced EDID functions.
31 IP CONTROL - MANAGE EDID SET INPUT T O DEF AUL T EDID Pressing the “SET INPUT T O DEF AUL T EDID” button will display additional options. The following page will open. On this page the user can select which LOCAL memory locations will be overwritten with a built-in EDID stored in the 16x16 DVI Matrix.
32 IP CONTROL - MANAGE EDID COPY EDID Pressing the “COPY EDID” button will display additional options. The following page will open. On this page, the user can select an EDID from either the LOCAL memory locations (Input) or from a display that is currently attached to any output, and copy that EDID to any other LOCAL memory location.
33 IP CONTROL - MASKING MASKING The Masking page is used to hide an output from displaying any video. From this page, all outputs can be set to “Active” or “Mask”. When an output is set to “Active”, it will function normally . When an output is set to “Mask”, it will not output any video.
34 IP CONTROL - IP CONFIGURA TION IP CONFIGURA TION The IP Con fi guration page is used to set the IP settings that will be used to access the unit using IP Control. The following items can be con fi gured from this menu. • IP Address (Default: 192.
35 IP CONTROL - BACKUP/REST ORE & POWER MANAGEMENT BACKUP/RESTORE The Backup/Restore page is used to backup and restore complete setup con fi gurations. NOTE: This feature will be implemented in a future release. POWER MANAGEMENT The Power Management page is used to set optional +5V power on an input to power speci fi c optional devices.
36 Switching and Masking without the Web Interface The Gefen 16x16 DVI Matrix uses HTML form attributes to communicate to the box. It uses the ‘method’ attribute with the ‘get’ value to send a command. The Matrix has a set of values that sends a valid command to perform switching and masking.
37 Switching T able Input / Output Port V alue 10 21 32 43 54 65 76 87 98 10 9 11 A 12 B 13 C 14 D 15 E 16 F Examples Single Output http://192.168.0.70/cgibin.shtml?a=s&o=0&i=0 Assigns Input 1 to Output 1. http://192.168.0.70/cgibin.shtml?a=s&o=a&i=2 Assigns Input 3 to Output 1 1.
38 Masking When masking output ports, there are two states: Active and Masked. Multiple ports or all ports can be masked with a single command. It is possible to com- bine masking and activating multiple ports using a single command. Below is the syntax for the MASK command.
39 Masking Command Masking Command V alue Activate 0 Mask 1 Examples http://192.168.0.70/cgibin.shtml?a=m&o0=1 * Masks Output 1. If the masking command value is set to 0, Output 1 will be re- enabled. http://192.168.0.70/cgibin.shtml?a=m&o5=0&oA=1&o3=1&oF=0 Masks Output 1 1 and 4 while activating Output 6 and Output 16.
40 FIRMW ARE UPDA TE FIRMW ARE UPDA TE PROCEDURE T o Begin the update procedure the unit’s Boot Loader must be activated. T o activate the Boot Loader please follow the procedure below: If the unit is already powered on, the following RS-232 command can be used to activate the Boot Loader: 1.
41 FIRMW ARE UPDA TE Follow the on-screen instructions to complete the fi rmware update process: 1. Press [1] on the computer keyboard to begin downloading program to the temporary memory . 2. A message will appear in Hyperterminal: Waiting for the fi le to be sent .
42 W ARNING MESSAGES Fan Failure The 16x16 DVI Matrix uses an internal fan to maintain a stable operating temperature in various environments. In the case that the fan fails to start, an alert will ap.
43 Critical Malfunctions T emperature Failure If the measured system temperature exceeds 85° C, the following message will be displayed on the LCM: Power Failure If the power reading exceeds the tole.
44 Video Ampli fi er Bandwidth ................................................... 165 MHz per channel Single Link Range ........................................................... .....................1920x1200 Input Video Signal ...................
45 Gefen warrants the equipment it manufactures to be free from defects in material and workmanship. If equipment fails because of such defects and Gefen is noti fi ed within two (2) years from the d.
46 lwIP is licensed under the BSD licence: Copyright (c) 2001-2004 Swedish Institute of Computer Science. All rights reserved. Redistribution and use in source and binary forms, with or without modi fi cation, are permitted provided that the following conditions are met: 1.
.
Pb.
Een belangrijk punt na aankoop van elk apparaat Gefen EXT-DVI-16416 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Gefen EXT-DVI-16416 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Gefen EXT-DVI-16416 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Gefen EXT-DVI-16416 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Gefen EXT-DVI-16416 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Gefen EXT-DVI-16416 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Gefen EXT-DVI-16416 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Gefen EXT-DVI-16416 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.