1 Heat Recovery V entilators INST ALLA TION, OPERA TION AND MAINTENANCE MANUAL HRV -150 • HRV -150D HRV -200 • HRV -200D • HRV -300D Y our ventilation system should be installed in conformance w.
2 T ABLE OF CONTENTS TECHNICAL DA T A HRV(D) Series .................................................................................................. 3 HRV Series .......................................................................................
3 HRV Series HRV 150D & HRV 200D Introducing the NEW Heat Recovery V entilators (HRV). As with previous designs, incoming fresh outdoor air is filtered before it is heated by the stale outgoing air through a aluminum heat recovery core.
4 Dimensions A B CD E 5 TH port for recirculation defrost type models only 0 0.2 0.4 0.6 0.8 1 1.2 0 50 100 150 200 250 300 40 08 0 SHR(D) 1505R SHR(D) 1505R SHR(D) 2005R 120 160 Airflow (cfm) Airflow.
5 Introducing the NEW Heat Recovery V entilators (HRV). As with previous designs, incoming fresh outdoor air is filtered before it is heated by the stale outgoing air through a aluminum heat recovery core.
6 Dimensions A B C D E 0 0.2 0.4 0.6 0.8 1 1.2 0 50 100 150 200 250 300 40 08 0 SHR 1504 SHR 1504 SHR 2004 120 160 Airflow (cfm) Airflow (L/s) Static Pressure (in WC) Static Pressure (Pa) 200 240 19 0.
7 Introducing the NEW Heat Recovery V entilators (HRV). As with previous designs, incoming fresh outdoor air is filtered before it is heated by the stale outgoing air . The HRV then distributes the preheated fresh filtered air throughout the home by direct ductwork installed specifically for the HRV or thr ough the ductwork of a forced-air system.
8 Dimensions 22.20" 5 64mm 17.36" 4 41mm 2.20" 56mm 2.20" 56mm 50.87" 1292mm 5 TH port for recirculation defrost type models only 0 0.2 0.4 0.6 0.8 1 1.2 0.00 50.00 100.00 150.00 200.00 250.00 300.00 40.00 0.00 80.00 S HR3005R 120.
9 OPERA TION Winter: Humidity control is very important during the winter months. This is when problems will be most apparent since condensation on the windows will often occur . The colder the outside temperature, the greater the risk of condensation in the home.
10 15-min T imer - RT -15M - The 15-minute remote timer is typically installed in areas where contaminated such as moisture and odors, are produced. Simply push the button and the HRV will activate to high speed for 15 minutes.
11 OPERA TION (CONT'D) OPTIONAL DIGIT AL CONTROL Note: All controls are low voltage. 18 to 24 gauge wire is recommended. FIL TER LIGHT RESET & MODE FAN SPEED SELECTOR Pr ess to reset the filter mainte- nance reminder light.
12 • Install the unit close to the outside wall on which the supply and exhaust hoods will be mounted. • Have a nearby power supply 120 V olts, 60Hz. • Have the possibility of mounting the unit to suppor ting beams. • Mount the unit as level as possible in or der to allow pr oper condensate drainage.
13 3 Push the hood into the opening. Attach the hood to the outside wall with mounting screws. Repeat the installation procedure for both the Supply and Exhaust hood. 2 Pull the insulated flexible duct through the opening until it is well extended and straight.
14 PRACTICAL TIPS INST ALLING DUCTS TO / FROM INSIDE • Building Codes and Combustion Appliance Installation Codes do not allow location of return air grilles or any opening such as a “breathing tee” in an enclosed room with spillage susceptible combustion appliances.
15 • For new construction, the rigid ducts are run in the walls. • Choose the location for your Supply and Exhaust grilles. The Supply grilles should be located in every habitable room and the Exhaust Grilles should be located in the wet rooms.
16 Bedrooms Fresh Air Exhaust Air Central Control - optional Fresh air to living room Exhaust Bathroom 460 mm 1800 mm HRV Ducting Fifth Port Units All HRV(D)’ s have a fifth duct port on top of the unit. This duct port is for both defrost and the recirculation mode.
17 Bedrooms Fr esh Air Exhaust Air Furnace thermostat Exhaust Bathroom 460 mm HRV Central Control - optional Return Air HRV Connection 1800 mm INST ALLA TION EXAMPLES (CONT'D) Example diagram onl.
18 INST ALLA TION EXAMPLES (CONT'D) DIRECT CONNECTION of both the HRV SUPPL Y AIR STREAM and EXHAUST AIR STREAM to the FURNACE COLD AIR RETURN Simplified Installation Option 1 (Return/Return Meth.
19 INST ALLA TION EXAMPLES (CONT'D) DIRECT CONNECTION of both the HRV SUPPL Y AIR STREAM & EXHAUST AIR STREAM to the FURNACE COLD AIR RETURN & SUPPL Y AIR SIDE Simplified Installation Opt.
20 AIR FLOW BALANCING CAUTION • If the unit’ s airflows are not properly balanced... - The unit may not operate at it’ s maximum efficiency. - Heat recovery core damage may occur . - The unit’ s use could cause negative or positive pressure in your home causing cold air to enter or other combustible equipment to backdraft.
21 AIR FLOW BALANCING (CONT'D) 1 For this flow measuring station, cut the duct and place the flow measuring station between each station. Make sure that the flow measuring station’ s air direction arrow points in the direction of the airflow. Secure the flow measuring station with duct tape.
22 MAINTENANCE The filters (2) need to be checked and cleaned every three months or when they appear dirty . Wash in warm sudsy water (mild detergent) or use a soft brush vacuum. The filters should be replaced when they can no longer be cleaned properly .
23 TROUBLESHOOTING Solutions Causes Problem Dehumidistat control is set too low Dehumidistat control is set too high Sudden change in temperature Storing too much wood for heating Dryer vent exhaust i.
24 ELECTRICAL CONNECTIONS Low V oltage Control Wiring Connections * Please see instruction on individual controls for proper wiring and set up of control selected.
25 ELECTRICAL CONNECTIONS (CONT'D) - + C ustom defrost m ode jumper selection 3 position mode selection switch Accessor y Control Contact (Open & Closes contact when HR V/ERV is ON/OFF) Diagn.
26.
27.
The product is manufactured by Fantech, Inc. Fantech reserves the right to modify , at any time and without notice, any or all of this product's features, designs, components and specifications. Item #: 402950 Rev . 1 Rev Date: 11022006 United States 1712 Northgate Blvd.
Een belangrijk punt na aankoop van elk apparaat Amana HRV-150D (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Amana HRV-150D heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Amana HRV-150D vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Amana HRV-150D leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Amana HRV-150D krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Amana HRV-150D bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Amana HRV-150D kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Amana HRV-150D . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.