Gebruiksaanwijzing /service van het product 005262-0 van de fabrikant Generac
Ga naar pagina of 56
ST ANDBY GENERA T OR O WNER'S MANU AL This manual should remain with the unit. A ne w standar d of reliability Serial Number QT 2.4L 45kW Model: 005262-0 — CAUTION — ONL Y QU ALIFIED ELECTRICIANS OR CONTRA CT ORS SHOULD A TTEMPT INST ALLA TION! Cover044 Re v .
Standby Generator Sets T able of Contents SECTION P AGE SAFETY RULES ................................................ 1-1 INTRODUCTION ..................................................... 1-3 Read this Manual Thoroughly ..............................
Study these SAFETY RULES carefully before install- ing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , efficiently and reli- ably only if it is properly installed, operated and maintained.
• Before performing any maintenance on the gen- erator , disconnect its battery cables to prevent accidental start -up. Disconnect the cable from the battery post indicated by a NEGA TIVE, NEG or (–) first. Reconnect that cable last. • Never use the generator or any of its parts as a step.
1-3 I NTRODUCTION Thank you for purchasing this model of the standby generator set product line. Every effort was expended to make sure that the information and instructions in this manual were both accurate and current at the time the manual was written.
I DENTI F ICA TION R EC ORD D A T A LA BE L Every generator set has a DA T A LABEL that contains important information pertinent to the generator . The data label, which can be found attached to the g.
E QUIPM ENT DE SCRI PTION This equipment is a revolving field, alternating cur - rent generator set. It is powered by a gaseous fueled engine operating at 1800 rpm for 4-pole direct drive units, 3600 rpm for 2-pole direct drive units and 2300 - 3000 rpm for quiet drive gear units.
ENGI N E P RO TE CTIVE DEVICE S The standby generator may be required to operate for long periods of time without an operator on hand to monitor such engine conditions as coolant tempera- ture, oil pressure or rpm.
F U E L SYST E M FUE L RE QUIRE MEN T S The standby generator may be equipped with one of the following fuel systems: • Natural gas fuel system • Propane vapor (PV) fuel system The Manual Drawing .
SP ECIF ICA TIONS GEN ERA T OR T ype ............................................................................. Synchronous Rotor Insulation ................................................................... Class H Stator Insulation .............
COLD WEA THER KIT F or cold climates, optional cold weather kit (part number 0F6148) is recommended. The kit includes: • Battery W armer • 4” Junction Box with hardware • 6 qt. pack 5W -30 synthetic oil (engine) R EC ON F IGU R I NG TH E F U EL SY STEM NOTE: All models are configured for natural gas or LP vapor from the factory .
GEN ER A T OR A C LEAD C ONN ECTIONS See “V oltage Codes”. This generator may be rated at any one of three voltages, either single -phase or three -phase. The electrical wires in the unit ’s AC con- nection (lower) panel should be installed according to the number of leads and the voltage/phase required for the application.
I NST ALL A TION Refer to the separate “Installation Guide QT Product Line” supplied with the unit. P R EP ARA TION B EFOR E S T ART -U P The instructions in this section assume that the standby generator has been properly installed, ser - viced, tested, adjusted and otherwise prepared for use by a competent, qualified installation contractor .
S T ART -U P CH ECKLIS T Before working on the generator , ensure the fol- lowing: • The AUTO/OFF/MANU AL switch is in the OFF position. • The 120V AC supply to the battery charger is switched OFF . P REP AR A TION FOR S T ART -UP • Ensure that the 120V AC circuit breaker to the bat - tery charger is open.
GEN ER A T OR C ONTROL AND OP ER A TION Refer to the appropriate control panel operator’s manual for this unit. OP ER A TI NG U N IT WITH MAN U AL TR ANSF ER SWIT CH If the generator was installed in conjunction with a transfer switch capable of manual operation only , the following procedure applies.
MAI NTENANCE P ER FOR M ED B Y AUTHOR IZED SERVICE F A CILITI ES Before working on the generator , ensure the fol- lowing: • The AUTO/OFF/MANU AL switch is in the OFF position. • The 15A fuse has been removed from the con- trol box. • The 120V AC supply to the battery charger is switched OFF .
Figure 10.1 - Oil Dipstick and Oil Fill Cap Oil Fill Cap Oil Dipstick B A TTE R Y FL UID Check battery electrolyte fluid based on the Maintenance Schedule. Fluid should cover separa- tors in all battery cells. If fluid level is low , add dis - tilled water to cover tops of separators.
CHANGI NG ENGIN E OI L Refer to maintenance performed by authorized service facilities for engine oil and filter change frequencies. Drain the oil while the engine is still warm from run- ning . This means warm up the engine, shut it down and drain immediately as follows: 1.
M ISCELLAN EOUS MAINTENANCE CLEAN ING TH E GEN ER A T OR Keep the generator as clean and as dry as possible. Dirt and moisture that accumulates on internal gen- erator windings have an adverse effect on insulation resistance. P eriodically clean generator exterior surfaces.
SERVICE S CH EDU LE 30 KW - 1 5 0 KW ST ANDBY GAS ENGIN E DR IVEN GEN ER A T OR SET S The following is a recommended maintenance schedule for standby gas engine driven generator sets from 30kW to 150 kW in size. The established intervals in the schedule are the maximum recommended when the unit is used in an average service application.
Maintenance Level 1 Level 2 Level 3 Level 4 Level5 T asks Recom- T ask Required T ask Required T ask T ask Required T ask mended Comp. to be done Comp.
Maintenance Level 1 Level 2 Level 3 Level 4 Level5 T asks Recom- T ask Required T ask Required T ask T ask Required T ask mended Comp. to be done Comp.
Maintenance Level 1 Level 2 Level 3 Level 4 Level5 T asks Recom- T ask Required T ask Required T ask T ask Required T ask mended Comp. to be done Comp.
TROU B LESHOO TING GU I DE P ROB LEM CAUSE C OR R ECTION Engine won’t crank. 1. 15 amp fuse blown. 1. Replace fuse. 2. Loose or corroded or defectiv e 2. Tighten, clean or replace batter y cables. batter y cables as necessary . 3. Defectiv e star ter contactor .
Standby Generator Sets Notes.
Standby Generator Sets Notes.
Standby Generator Sets Notes.
.
1 0F3137 1 PAN CB CO NN BOX 2 0F3188 1 STAND RH CO NTR O L 3 0F3189 1 STAND L H CON TROL 4 0 23 484 N 1 BU SHI NG SNAP SB-2 .5-3 1 5 *** 0F6366B 1 / 2 XFMR DUAL 12 0V/16V (F OR 1 20/240V & 277 /48.
.
5) UL CIRCUIT BREAKE R (QJ-2P) A 0F8137 1 COVER QJ 2P FRM CB B 065469 1 DECAL, DA NGE R HIGH V OLTAGE C 0E799 4 - CB 0225 A 2 40V 2P S QJ 22 D 0F 8136 1 COVER QJ 2P CB DI SH E 036261 4 RI VET POP .
.
1 0G00 56 1 RTR-23 9 0--35K D1 CPL 0F96 77 1 RTR-23 9 0--45K D1 CPL 2 0G 0057 1 STR -2390 --35AD1 CPL 0F96 64 1 S TR 39 0 45 K 2P 1P H DI RE CT 0G00 58 1 S TR- 2 39 0-- 3 5 KD 1 CP L 0G01 84 1 S TR 39.
.
1.) C2 UN ITS A 0F98 32 1 S HIELD CO NN BO X C 2 0F98 32G GS0 R 1 SHIE LD C ONT ROL S TA ND C 2 B 0C24 5 4 3 S CRE W THF M6- 1 X 16 N WA Z/ JS 2.) C3 UN ITS A 0F9 8 32B 1 S HIE LD CO NT ROL S T AND C 3 0F98 32K GS 0R 1 S HIE LD C ONT ROL S TAND C 3 B 0C245 4 3 SCRE W THF M6- 1 X 16 N WA Z/ JS 3.
.
COM P O NE NTS I N C LU DE D IN 0F 969 6E 1 0F18 23A 1 ENCL HSB CO NT RO L PANE L 2 0F30 78 1 COVER CO NTR OL PANE L 3 0F2 6 06 1 HIN G E C ONT INUOUS H-P A NEL 4 036261 6 RI VET POP .
.
1 0F 95 17 1 W ELDM ENT FRAM E 2.4L C2 2 0528 60 4 NUT FL ANGE D HE X M1 2-1 .75 3 0522 51 5 DAMPE NER V I BRATIO N 40 B LUE 4 052 257 5 SPA CER .49 X .62 X 1.87 PWDR/ZNC 5 0522 52 5 DAMPE NER V I BRATIO N 6 0522 59 5 WASHE R FL AT M 12 7 0528 91 5 SCREW HHC M 12- 1.
.
1 0F34 08B 1 BAT TERY TR AY C1 CPL 2 0F 3 4 11 1 STRAP BA T TE RY RET AI NM ENT 3 0255 07 REF W ASHE R S HAKEP ROO F EXT 7/1 6 ST L 4 0526 47 RE F SCREW SH C M 10-1.
.
1 0G0158 1 E NGINE 2 .4L HY UNDAI 2 0221 31 3 W ASHE R FL AT 3/8- M1 0 ZI NC 3 0F9585 1 EXHAUST A DAPTE R 2.4L M ACH 4 0465 25 3 NU T HE X M 10- 1. 25 G8 YE L CH R 5 05 2212 1 (REF) SCREW HH C M10- 1.
.
1 0F9529 1 WELDMENT RADIATOR SUPPORT 2.4L 2 0F2608 1 RADIATOR 598 X 568 X 49 CPL RH 3 0F5263 1 V-BELT 31/6 4" X 57-3/ 8" 40 4 6 5 2 6 5 W A S H E R L O C K M 1 0 5 0599 81 4 SCREW HH C M 10- 1.5 X 30 G 10.9 6 0222 2 2 2 SCREW HH C 5/ 16- 2 4 X 1- 1/ 2 G5 7 0F5050 1 SHIELD RAD IATOR C5 8 04 2568 8 S CREW HH C M6-1.
.
1 0E6 586 1 GASKET BOSCH 32 & 40 2 0E0519 A 1 ADA PTER CARBUR ETOR W/PVC CONN 3 0C 8127 1 ELE MENT AIR CLE ANE R 4 0526 19 4 SCREW HH C M 5-0. 8 X 2 0 G 8.8 5 022 127 1 NU T HEX 1/4 -20 STEE L 6 0629 74 1 STUD TH 1/4- 20 X 4- 1/ 2 G2 ZNC 7 0G01 90 1 PLAT E , AI R CLE A NE R TO P 2.
.
1 0269 1 5 2 NIPP LE CLO SE 3/ 4 X 1. 37 5 2 075580 1 FLANGE FUEL I NLET 3 0F6390B 1 REGU LATOR AS SY 2. 4L 4 0392 5 3 2 SCREW HH C M8- 1. 2 5 X 20 G 8.8 5 0221 45 2 WASHE R F LAT 5/ 16-M 8 Z IN C 60 2 2 1 2 9 2 W A S H E R L O C K M 8 - 5 / 1 6 7 0457 71 2 NUT HEX M 8-1.
.
1 0G0045 (XX) 1 REA R WRA P C2 CPL 2 0C 24 5 4 54 SCREW THF M6-1 X 16 N WA Z/ JS 3 0F5849 (XX ) 2 DOOR C2 4 087233 2 RI V ET POP .1875 X .450 SS 5 0E325 7 4 SCRE W T H-F RM M6 W/CA P SHK PRF W 6 0F585.
.
1 0F 97 94 1 MUFFLE R 7" X 9" X 1 8-1/ 2" 2" I N/O UT 2 0G01 13 1 EXHAUS T EL BOW 2 1/4 O D 2 1/ 2OD 3 0F 9937 1 BR ACKE T MU FFLE R 4 0F2830 1 MUFFLER BRACKET STIFFE NER 5 0F2962 1 MUFFLER STRAP 6 0807 62 2 BOLT U 3/8- 16 X 2.
.
.
Standby Generator Sets W arranty Printed in U.S.A. GENERA C PO WER SYSTEMS ST ANDARD LIMITED W ARRANTY FOR HOME ST ANDBY/LIGHT COMMERCIAL PRODUCT 45kW AND BELO W For a period of two (2) y ears from the date of sale, or start-up by A uthorized/Cer tified Generac P ow er Systems Dealer , or branch thereof , Generac P ow er Systems, Inc.
Een belangrijk punt na aankoop van elk apparaat Generac 005262-0 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Generac 005262-0 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Generac 005262-0 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Generac 005262-0 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Generac 005262-0 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Generac 005262-0 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Generac 005262-0 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Generac 005262-0 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.