Gebruiksaanwijzing /service van het product P300 van de fabrikant Giant
Ga naar pagina of 16
Series P 300 Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Contents: Installation Instructions: page 2 Pump Specifications: pages 3-7, 10 Exploded View: page 8 Parts L.
2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connections, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
3 NOTES: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
4 Specifications Model P316 U.S. (Metric) 1450 RPM Ratings (Continuous) .................................... 4.4 GPM @ 3000 PSI ..... (16.7 LPM @ 200 bar) Ratings (Intermittent) .................................... 4.4 GPM @ 3500 PSI ..... (16.7 LPM @ 240 bar) 1750 RPM Ratings (Continuous) .
5 Specifications Model P317 NOTES: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
NPSHR (FT -HEAD) 50 68 86 104 122 140 158 176 194 212 230 0 F 69.0 66.0 62.3 59.0 56.8 52.5 49.2 46.0 43.0 39.3 36.0 33.0 30.0 26.2 1 7 3 0 R P M 6 . 2 2 G P M 1 4 2 0 R P M 5 1 G P M P318 NPSHR Chart P318 HORSEPOWER REQUIREMENTS RPM GPM 750 PSI 1000 PSI 1500 PSI 1750 PSI 2000 PSI 810 3.
P319 HORSEPOWER R EQUIREMENTS RPM GPM 1500 PSI 2000 PSI 2500 PSI 3000 PSI* 3000 4.2 4.3 5.8 7.2 8.7 3200 4.5 4.7 6.2 7.8 9.3 3450 4.8 5.0 6.6 8.3 9.9 7 Specifications Model P319 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.
8 Exploded View - P300 Series.
9 P300 SERIES PAR TS LIST ITEM PART NO. DESCRIPTION QTY. 1 08326 Crankcase 1 2 06773 Dipstick Assembly 1 3 08410B Crankcase Cover, Short 1 3 08410-LG Crankcase Cover, Extended 1 3 A 07190 Oil Drain Pl.
P340 HORSEPOWER R EQUIREMENTS RPM GPM 1500 PSI 2000 PSI 2500 PSI 3000 PSI 3500 PSI 4000 PSI* 745 1.5 1.6 2.1 2.6 3.1 3.6 4.1 1025 2.0 2.1 2.8 3.4 4.1 4.8 5.5 1340 2.7 2.8 3.7 4.7 5.6 6.5 7.4 1450 2.9 3.0 4.0 5.0 6.0 7.0 8.0 1750 3.5 3.6 4.8 6.0 7.2 8.
11 Position Item# Description T or que Amount 3 B 08410/07190 Oil Drain Plug w/ Gasket 222 in.-lbs. 6 07188/1196 Screw 43 in.-lbs 1 0 7225 Screw with Lock W asher 85 in.-lbs. 1 6 C 08456 or 08450 T ension Screw , Plunger 220 in.-lbs. 3 4 08363 Hex Head Cap Screw , V alve Casing 222 in.
PUMP SYSTEM MALFUNCTION 12 PUM P SYST EM M A L FUNC TION S MALFUN CTION CAU SE REM EDY The Pressu re and/ or t he Deliver y Dro p s W orn pac k ing se als Re pl ac e pac k ing se als Brok en valve spr.
13 REPAIR INSTRUCTIONS - P300 SERIES NOTE: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.e., the elastomers) from cutting and scoring.
14 11. Inspect o-rings (#21 and 22) and replace as necessary. 9. Remove the pressure rings (#24) and grooved seals (#23) from the valve casing (#26). Inspect parts for wear and replace if necessary. For P318 only, the spacers (#23A) can now be removed.
15 Reassembly sequence of the P300 Series pump REPAIR INSTRUCTIONS - P300 SERIES 14. If the oil seals (#19) were removed, replace them with the primary seal lip (grooved side) towards the crankcase and the dust lip (tapered end) towards the valve casing (#26).
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-serve car wash applications, the discharge manifolds will never fail, period.
Een belangrijk punt na aankoop van elk apparaat Giant P300 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Giant P300 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Giant P300 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Giant P300 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Giant P300 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Giant P300 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Giant P300 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Giant P300 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.