INST ALLA TION AND OPERA TING INSTRUCTIONS FOR VENT -FREE OR VENTED INST ALLA TIONS GOLDEN BLOUNT “TEXAS FLAME II” GAS LOGS N A TURAL GAS OR L.P . 18“ - 24“ & 30“ SIZE SETS The Golden Blount vent-free gas log sets comply with the National Saf ety Standards and are tested and design cer tified b y CSA to ANSI Z21.
IMPOR T ANT! Read all instructions carefully bef ore starting installation. F ailur e to follo w these instructions may result in pr operty damage, personal injury or possible loss of life SAFETY AND GENERAL INFORMA TION • Use correct gas type for y our appliance.
CAUTION SET SIZE FIREPLA CE WIDTH DEPTH OPENING HEIGHT FRONT BA CK 18" 24" 18" 14" 20" 24" 30" 21 1/2" 16" 21" 30" 36" 30" 16" 21" NO TE! CARBON MONO XIDE POISONING MA Y LEAD T O DEA TH.
BURNER SYSTEM INST ALLA TION Model GB-TFII-18 GB-TFII-18 GB-TFII-24/30 GB-TFII-24/30 Gas T ype Natural L. P . Natural L. P . Max Input 30,000btu/hr 30,000btu/hr 38,000btu/hr 35,000btu/hr Min Input 19,000btu/hr 26,000btu/hr 22,700but/hr 28,500btu/hr Gas Inlet Pressure Maximum 10.
PLA CEMENT OF LOGS - 18” SETS Front ember log sits under front ember burner tube as shown. Bottom back log is to be placed on back of grate and against burner support brackets as illustrated. Notches in bottom log will go over grate bar . Bottom front log is to be placed on front of grate and against front uprights as illustrated.
PLA CEMENT OF LOGS - 24” & 30” SETS 6 Front ember log sits under front ember burner tube as shown. Bottom back log is to be placed on back of grate and against burner support brackets as illustrated. Notches in bottom log will go over grate bar .
FOR Y OUR SAFETY READ BEFORE LIGHTING W ARNING: If y ou do not f ollow these instructions exactly , a fire or e xplosion ma y result causing proper ty damage, personal injur y or loss of lif e. A. This appliance is equipped with a push-button piezo ignition de vice which automatically lights the pilot.
LIGHTING INSTR UCTIONS “MILLIV OL T V AL VE” 1. ST OP! Read the saf ety inf or mation pre viously listed abov e. 2. Mak e sure manual shutoff v alve is fully open. 3. Set roc ker s witch to OFF position. 4. Press in and tur n control knob clockwise to the OFF position.
TO TURN OFF GAS TO APPLIANCE “MILLIV OL T V AL VE” CONT . SHUTTING OFF HEA TER 1. T ur n control knob cloc kwise to the OFF position. 2. Set roc ker s witch to OFF position Shutting off burner s only (pilot sta ys lit) Y ou ma y shut off burner and keep the pilot lit b y doing one of the f ollowing.
ITEM QU ANTITY DESCRIPTION 1 1 TF-II-18 T OP LEFT LOG 2 1 TF-II-18 T OP RIGHT LOG 3 1 TF-II-18 BO TT OM BACK LOG 4 1 TF-II-18 BO TT OM FRONT LOG 5 1 TF-II-18 FRONT EMBER LOG 6 1 TF-II-24/30 MIDDLE LEF.
TROUBLESHOOTING REFERENCE SYMPT OM POSSIBLE CA USES CORRECTIVE A CTION 1. Pilot will not light with A. Main shutoff valv e closed. 1. Make sure that the shutoff valv e Piezo ignitor located on the pipe supplying gas to the fireplace is open. B. Air in the gas line.
Een belangrijk punt na aankoop van elk apparaat Golden Blount 18" - 24" & 30" (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Golden Blount 18" - 24" & 30" heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Golden Blount 18" - 24" & 30" vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Golden Blount 18" - 24" & 30" leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Golden Blount 18" - 24" & 30" krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Golden Blount 18" - 24" & 30" bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Golden Blount 18" - 24" & 30" kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Golden Blount 18" - 24" & 30" . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.