Copyright © 2009 Goodman Manufacturing Company, L.P. RT6322008r3 August 2009 This manual is to be used by qualified, professionally trained HV AC technicians only . Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person.
PRODUCT IDENTIFICA TION 2 The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. WARNING WARNING HIGH VOLTAGE! Disconnect ALL power before servicing or installing this unit.
PRODUCT IDENTIFICA TION 3 GPC1524M41A* GPC1530M41A* GPC1536M41A* GPC1542M41A* GPC1548M41A* The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
4 PRODUCT DESIGN GPC Package Cooling Units are designed for outdoor instal- lations only in either residential or light commercial applica- tions and are available in 2, 2-1/2, 3, 3-1/2 and 4 ton sizes. They are designed for 208/230 volt single phase applications.
PRODUCT DESIGN 5 Roo f Cur b Rooftop Installation - Multi-positional (M) NOTE: To ensure proper condensate drainage, unit must be installed in a level position.
6 PRODUCT DESIGN HKR ELECTRICAL DA T A All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration.
PRODUCT DIMENSIONS 7 BLOWE R ACCE SS P ANEL ? ? 2 3 4 51 47 SUP PL Y 1 3/8 A RET URN POWE R WI R E ENT RANCE 4 1/8 2 1/8 6 ½ 16 16 5 ½ B B CONTROL WI R E ENT RANCE CONDENS A TE DRAI N CONNECTIO N 3 .
P ACKAGE COOLING SPECIFICA TIONS 8 All wires and overcurrent protection devices are sized for use with electric heaters only and without refrigeration.
ACCESSORIES 9 P a rt Nu m b e r D es c ri p t io n O T 18- 60 A O ut door Ther mosta t Kit w/Lo c kout S tat O T /EHR 18- 60 Eme r genc y Heat R el ay Ki t HKR Electric Heat Ki t P G C101/10 2/103 Roo.
10 BLOWER PERFORMANCE DA T A Dry Coil Data GPC15[24-48]M41A* NOTES: • Data shown is Dry Coil. Wet Coil Pressure Drop is approximate. 0.1" H 2 O, for 2 row indoor coil; 0.2” H 2 O, for 3 row indoor coil; and 0.3” H 2 O, for 4 row indoor coil.
BLOWER PERFORMANCE DA T A 11 30 40 50 6 0 70 80 90 110 1 20 100 13 0 14 0 150 100 90 80 70 60 50 40 30 20 10 OUT PU T B TU/ H R x 10 00 BT U OUTPUT vs TEMPER AT URE RISE CHART TEMPERAT URE RISE 600 CF M 700 900 1000 1100 1200 140 0 160 0 1800 2000 220 0 240 0 C FM FORMULA S BTU OUTPUT = CFM x 1.
12 COOLING PERFORMANCE DA T A GPC1524M41* MOD E L : G PC 1524M41 EX PAN DE D P ER F O R M A N C E D ATA C OOL ING OP ER AT I ON De sign S ubco oli n g, 7 °F @ the li quid a cc e s s fitt i ng conn e c t i o n AHR I 95 t e st c onditions. D e s i gn S upe rhe at 5 ° F @ t h e c om p re ss or s u cti o n acc ess f it t ing co n n ec t i o n .
13 COOLING PERFORMANCE DA T A GPC1524M41* MOD E L : G PC 1524M41 EX PAN DE D P ER F O R MANC E D ATA C OOL I NG OP ER AT ION De sign S ubco oli n g, 7 °F @ the liq ui d a c c ess fi tt in g c onne c tio n AHR I 95 t e s t c onditi ons . D e s i gn S uperhe at 5 ° F @ t he c omp re ss or s ucti o n acc ess f it tin g co n n ec ti o n .
14 COOLING PERFORMANCE DA T A GPC1530M41* MOD E L : G PC 1530M41 EX PA N DE D P ER F OR M A N C E D ATA C OOL ING OP E R ATI ON De sign S ubco oli n g, 7 °F @ the l i qui d a c c e ss fitt i ng conn e c ti o n AHR I 95 t e st c ondi tions . D e s i gn S upe rhe at 5 ° F @ t he comp re ss or s ucti o n acc ess f it ting co n n ec t i o n .
15 COOLING PERFORMANCE DA T A GPC1530M41* MOD E L : G PC 1530M41 E XP A ND ED PE RF O R M A N CE DA T A C OOL IN G OP ERAT ION De s i gn S ubc ooli n g, 7 °F @ the l i quid a c c e s s fi tt i ng c onne c ti o n AH R I 9 5 t e st conditions . D e sign S uperhe a t 5 ° F @ t he comp re s s or s uct ion ac c es s f i t ti ng c onne c ti on.
16 COOLING PERFORMANCE DA T A GPC1536M41* MOD E L : G PC 1536M41 EX PAN DE D P ER F O R MANC E D ATA C OOL I NG OP ER AT ION Desi g n Su b co o l i n g , 7 ° F @ th e l iq u i d a cce ss fi t t in g co n nec t i o n AH R I 95 t est co n d i ti o n s.
17 COOLING PERFORMANCE DA T A GPC1536M41* MOD E L : G PC 1536M41 EX PAN DE D P ER F O R MANC E D ATA C OOL I NG OP ER AT ION De sign S ubco oli n g, 7 °F @ the liq ui d a c c ess fi tt in g c onne c tio n AHR I 95 t e s t c onditi ons . D e s i gn S uperhe at 5 ° F @ t he c omp re ss or s ucti o n acc ess f it tin g co n n ec ti o n .
18 COOLING PERFORMANCE DA T A GPC1542M41* MOD E L : G PC1542M41 E XP A ND ED PE RF ORM A N CE DA T A C OOL ING OP ER ATION Desi gn Su b coo l i n g , 7 ° F @ th e l iqu i d a cce ss fi tt ing co n n ec ti o n A H R I 95 t est con d i ti o n s. D e si g n S u p er h eat 5 ° F @ t h e com p r e ssor s uc ti on a cce s s f i t ti ng c onne c tion.
19 COOLING PERFORMANCE DA T A GPC1542M41* M O DEL : GP C1 5 4 2 M 4 1 E XP A ND ED PE RF ORM A N CE DA T A C OOL I NG OP ER AT ION Desi gn Su b coo l i n g , 7 ° F @ t he l iq ui d a cce ss f i t t ing co nn ec ti o n AH R I 95 t est co nd i t i o ns.
20 COOLING PERFORMANCE DA T A GPC1548M41* MOD E L : G PC 1548M41 EX PAN DE D P ER F O R MANC E D ATA C OOL I NG OP ER AT ION Desi g n Su b co o l i n g , 7 ° F @ th e l iq u i d a cce ss fi t t in g co n nec t i o n AH R I 95 t est co n d i ti o n s.
21 COOLING PERFORMANCE DA T A GPC1548M41* MOD E L : G P C 1548M41 E XP A ND ED P E RF O RM A N C E DA T A C OO LIN G OPE R A TIO N De sign Sub cooli n g, 7 °F @ the liq ui d a c ce s s fi tt i ng c onne c tio n AHR I 95 t e s t c ondi tions . D e s i gn S upe r he at 5 °F @ t he c omp re s s or s uc tion ac c e s s f i t ti ng c onne c ti on.
22 COOLING PERFORMANCE DA T A PERFORMANCE TEST All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoo r air cubic feet per minute (CFM) as listed in the Performance Data Sheets: If conditions vary from this, results will change as follows: 1.
WIRING DIAGRAMS 23 WARN I NG HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OURCES MA Y BE PR ESENT. F AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
24 WIRING DIAGRAMS Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. WARN I NG HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OURCES MA Y BE PR ESENT.
WIRING DIAGRAMS 25 WARN I NG HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT . MULTI PLE PO WER S OURCES MA Y BE PR ESENT. F AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
Een belangrijk punt na aankoop van elk apparaat Goodman GPC15 SEER (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Goodman GPC15 SEER heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Goodman GPC15 SEER vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Goodman GPC15 SEER leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Goodman GPC15 SEER krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Goodman GPC15 SEER bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Goodman GPC15 SEER kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Goodman GPC15 SEER . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.