C US ® Made in the USA by: Goodman Manufacturing Compan y , L. P. IO-230F 2550 North Loop West, Suite 400 - Houston, Texas 77092 08/04 ww w .goodmanmfg.
2 IO-230F 08/04 INDEX INTRODUCTION .................................................................... 2 REPLACEMENT P AR TS ........................................................ 2 SAFETY INSTRUCTIONS ..............................................
3 IO-230F 08/04 WARNING THIS PRODUCT IS F ACT OR Y SHIPPED FOR USE W ITH A 208-230/1/60 ELECTRICAL PO WER SUPPL Y . THIS AIR HANDLER MUST NOT BE RECONFIGURED T O OPERA TE W ITH ANY OTHER PO WER SUPPL Y . WARNING WHEN INST ALLING OR SER VICING THIS EQUIPMENT , SAFETY CLOTHING , INCLUDING HAND AND EYE PROTECTION, IS STRONGL Y ADVISED.
4 IO-230F 08/04 When matched with a Goodman or Amana brand condenser or heat pump, an ARI certified rating is available for many combinations. The AEPT models are equipped with an ECM TM moto r . An ECM TM motor is more efficient than a standard PSC motor and offers features such as soft-start, controlled off-delays, and constant CFM.
5 IO-230F 08/04 maximum heat and allow the system to reach steady state conditions. Insert two thermometers, one in the return air and one in the supply air. The temperature rise is the supply air temperature minus the room air temperature. Use HKR specification sheets to determine the HKR available for a given air handle r.
6 IO-230F 08/04 Wire Sizing W ire size is important to the operation of your equipment. Use the following check list when selecting the appropriate wire size for your unit. • Wire size must carry the Minimum Circuit Ampacity (MCA). Refer to the NEC (USA) or CSA (Canada) for wire sizing.
7 IO-230F 08/04 Piping Size For the correct tubing size, follow the specification for the condenser/heat pump. WARNING THIS COIL IS SHIPPED UNDER PRESSURE.
8 IO-230F 08/04 To increase the superheat (measured at the condenser base valve), turn the stem clockwise (in). Similarl y , to decrease the superheat, turn the stem counterclockwise (out).
9 IO-230F 08/04 To complete the conversion, slide the evaporator coil into t he chass i s and a tt ach t he t h r ee ( 3 ) access pane l s . (Figure 7). CONVERSION TO HORIZONT AL The “B” series product is not suitable for horizontal application and must not be used for this type of installation.
10 IO-230F 08/04 IMPOR T ANT NOTE: THE EV APORA T OR COIL IS COA TED WITH OILS THA T MA Y DISSOL VE STYROFOAM AND CER T AIN TYPES OF PLASTICS. THEREFORE, A REMOV AL PUMP OR FLOA T SWITCH MUST NOT CONT AIN ANY OF THESE MA TERIALS.
11 IO-230F 08/04 Humidity Control When using a Humidistat (normally closed), cut jumper PJ6 on the control board. The Humidistat will only affect cooling airflow by adjusting the Airflow to 85%. Two Stage Heating When using staged electric heat, cut jumper PJ4 on the control board.
12 IO-230F 08/04 C W2 O Y R YO C G R E W2 TYPICAL H/P ROOM THERMOSTAT HEAT PUMP AR/ARUF/ARPF/ARPT 18-60 10 KW & BELOW (OPTIONAL) OUTDOOR THERMOSTAT CLOSE ON TEMPERATURE FALL RED GREEN WHITE BLUE AR UNIT R Y O W BL #18 GA. 5 WIRE #18 GA. 7 WIRE SEE NOTE #3 R G BR W BL R E D Y E L L O W O R A N G E W H I T E B L U E #18 GA.
13 IO-230F 08/04 Quality Makes the Difference! All of our systems are designed and manufactured with the same high quality standards regardless of size or efficienc y . We have designed these units to significantly reduce the most frequent causes of product failure.
Een belangrijk punt na aankoop van elk apparaat Goodman Mfg AEPT (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Goodman Mfg AEPT heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Goodman Mfg AEPT vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Goodman Mfg AEPT leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Goodman Mfg AEPT krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Goodman Mfg AEPT bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Goodman Mfg AEPT kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Goodman Mfg AEPT . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.