© 2007 - 2012 Goodman Manufacturing Compa ny , L.P . 5151 San Felipe, Suite 500, Houston, TX 77056 www .goodmanmfg.com - or - www .amana-hac.com P/N: IO-431 Date: May 2012 ASPF AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.
2 Important Safety Instructions The following symbols and labels are used throughout this manual to indicate immediate or potential safety hazards. It is the owner’s and installer’s responsibility to read and com- ply with all safety information and instructions accompanying these symbols.
3 IMPORTANT: To register your Goodman ® brand unit, go to www.goodmanmfg.com and click on “Warranty Registration”. Complete registration as prompted. To register your Amana ® brand unit, go to www.amana- hac.com and click “Warranty Registraion”.
4 Return Ductwork DO NOT TERMINATE THE RETURN DUCTWORK IN AN AREA THAT CAN INTRODUCE TOXIC, OR OBJECTION- ABLE FUMES/ODORS INTO THE DUCTWORK. The return ductwork is to be introduced into the air handler bottom (upflow configuration). Return Air Filters Each installation must include a return air filter.
5 H I G H V O LTA G E ! Fail ure to do so may cause prop ert y dama ge , pe r s o n a l i n ju r y or dea t h . Dis connec t ALL pow er befor e s ervi cing.
6 Low Voltage Connections Several combinations of low voltage schemes are available, depending on the presence of a heat kit and whether the heat kit is single-stage or multi-staging. The low voltage con- nections are determined by whether the outdoor unit is a con- denser or heat pump.
7 Downflow Conversion Conversion to downflow MUST be performed in an area that allows access to all sides prior to placing the air handler in its final location. To prevent the evaporator coil pan from “sweat- ing” the DPI accessory insulation kit is to be used when per- forming this conversion.
8 ASPF Model Insulation Kit 1830 DPI H36-42 3137 / 42 60 DPIH48-6 1 Table 8 The following describes converting to “Horizontal Left-Hand”. Conversion MUST be performed in an area that allows ac- cess to all sides prior to placing the air handler in its final location ( See Figure 6 ).
9 Use of a condensate removal pump is permitted when nec- essary. This condensate pump should have provisions for shutting off the control voltage should a blocked drain occur.
10 ASPF Thermostat Connections NOTES: 1) OUTDOOR THERMOSTAT (OT-1) SHOULD BE THE FIRST TO CLOSE AND THE LAST TO OPEN. 2) JUMPER W1 AND W2 TOGETHER IF OT-2 IS NOT USED.
11 HIGH VOL T AGE ! DIS CO NNE CT A LL POW ER BE FO RE SERV ICI NG. MUL TIPLE PO WE R S OURC ES MA Y B E P RES EN T . F AILUR E T O DO SO MA Y C AU SE PR OPERT Y DA MAGE , P ER SON AL I NJU R Y OR DE A TH . WA R N I N G Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
12 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T AGE ! DIS CO NNE CT A LL POW ER BE FO RE SERV ICI NG. MUL TIPLE PO WE R S OURC ES MA Y B E P RES EN T . F AILUR E T O DO SO MA Y C AU SE PR OPERT Y DA MAGE , P ER SON AL I NJU R Y OR DE A TH .
13 HIGH VOL T AGE ! DIS CO NNE CT A LL POW ER BE FO RE SERV ICI NG. MUL TIPLE PO WE R S OURC ES MA Y B E P RES EN T . F AILUR E T O DO SO MA Y C AU SE PR OPERT Y DA MAGE , P ER SON AL I NJU R Y OR DE A TH . WA R N I N G Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
14 THIS P AGE LEFT INTENTIONALL Y BLANK.
15 SPLIT SYSTEMS AIR CONDITIONING AND HEA T PUMP HOMEOWNER’S ROUTINE MAINTENANCE RECOMMENDA TIONS We strongly recommend a bi-annual maintenance checkup be performed before the heating and cooling seasons begin by a qualified servicer .
16 © 2007 - 2012 Goodman Manufacturing Company , L.P . 5151 San Felipe, Suite 500, Houston, TX 77056 www .goodmanmfg.com - or - www .amana-hac.com NOTE: SPECIFICATIONS AND PERFORMANCE DATA LISTED HEREIN ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Een belangrijk punt na aankoop van elk apparaat Goodman Mfg ASPF Air Handlers (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Goodman Mfg ASPF Air Handlers heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Goodman Mfg ASPF Air Handlers vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Goodman Mfg ASPF Air Handlers leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Goodman Mfg ASPF Air Handlers krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Goodman Mfg ASPF Air Handlers bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Goodman Mfg ASPF Air Handlers kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Goodman Mfg ASPF Air Handlers . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.