Gebruiksaanwijzing /service van het product PG 15 van de fabrikant Goodman Mfg
Ga naar pagina of 28
Goodman Manufacturing Company , L.P . 5151 San Felipe, Suite 500, Houston, TX 77056 www .goodmanmfg.com © 2006 - 2009, 2012 Goodman Manufacturing Company , L.P . IO-324H 1 1/12 This Forced Air Central Unit Design Complies With Requirements Embodied in The American National S tandard / National S tandard of Canada Shown Below .
2 INDEX REPLACEMENT PARTS ............................................................................................................................... ........................ 4 O RDERING P ARTS .....................................................
3 MAINTENANCE .................................................................................................................................................................. 1 7 F IL TER R EPLACEMENT OR C LEANING ...................................
4 REPLACEMENT PARTS O RDERING P ARTS When reporting shortages or damages, or ordering repair parts, give the complete unit model and serial numbers as stamped on the unit’s nameplate. Replacement parts for this appliance are available through your contractor or local distributor .
5 CA RBON M ONOXIDE POISON ING HA ZA RD B10259-216 Carbo n monox ide produc ing devic es (suc h as an auto mobile, s pace heater , gas wat er heat er, etc.
6 Rooftop Installation • The unit may be installed directly on wood floors or on Class A, Class B, or Class C roof covering material. • T o avoid possible personal injury , a safe, flat surface for service personnel should be provided.
7 RIGGING DET AILS IMPORT ANT NOTE: If using bottom discharge with roof curb, ductwork should be attached to the curb prior to installing the unit. Ductwork dimensions are shown in roof curb installation instructions. Refer to the Roof Curb Installation Instructions for proper curb installation.
8 8. The unit must be connected to the building piping by one of the following methods: • Rigid metallic pipe and fittings • Semirigid metallic tubing and metallic fittings (Aluminum alloy tubing .
9 cooling. Units which will have economizers may use thermostats with two or three stages of cooling. All units can use single stage or multi-stage thermostats. Refer to figures later in this section for wiring. The units are designed for operation on 60 hertz current and at voltages as shown on the rating plate.
10 U NIT V OLTAGE The unit transformer is factory connected for 230V operation. If the unit is to operate on 208V , reconnect the transformer primary lead as shown on the unit wiring diagram. The induced draft blower on some models is equipped with a low speed 230V lead (blue) and a low speed 208V lead (black).
11 All ductwork exposed to the outdoors must include a weatherproof barrier and adequate insulation. A duct system should be inst alled in accordance with Standards of the National Board of Fire Underwriters for the Installation of Air Conditioning, W arm Air Heating and V entilating Systems.
12 NORMAL SEQUENCES OF OPERA TION H EATING This unit is equipped with an ignition control that automatically lights the main burner . DO NOT attempt to light the main burners by any other method. 1. Thermostat calls for low or high stage heating. 2. Induced draft blower energizes for 15-second pre-purge.
13 If the power to the unit is interrupted during the heating cycle, it may cause the secondary limit to trip. Once the blower compartment temperature drops below the limit reset temperature, the limit will automatically reset. Secondary Contro l Limit Back of Unit Secondary Limit Control Pre-Operation Checks 1.
14 With a properly designed system, the proper amount of temperature rise will normally be obtained when the unit is operated at rated input with the recommended blower speed. If the correct amount of temperature rise is not obtained, it may be necessary to change the blower speed.
15 space. It is the installing contractors responsibility to ensure the proper refrigerant sub-cooling at the condenser is adjusted for each application. As the outdoor ambient temperature rises the sub-cooling decreases and as the outdoor ambient temperature lowers, the sub-cooling increases.
16 A BNORMAL O PERATION - H EATING I NTERNAL C ONTROL F AILURE If the integrated ignition control in this unit encounters an internal fault, it will go into a “hard” lockout and turn off the diagnostic LED. If diagnostic LED indicates an internal fault, check power supply to unit for proper voltage, check all fuses, circuit breakers and wiring.
17 NOTE: Some electronic thermostats also have a built-in compressor short cycle timer that may be longer than the three minute delay given above. If you are using an electronic thermostat and the compressor has not started after three minutes, wait an additional five minutes to allow the thermostat to complete its short cycle delay time.
18 M AIN B URNER F LAME (Q UALIFIED S ERVICER O NLY ) Flames should be stable, soft and blue (dust may cause orange tips but must not be yellow). The flames must extend directly outward from the burner without curling, floating or lifting off. Ch eck the bur ner flam es fo r: 1.
19 APPENDIX.
20 HEA TING TIMING CHART COOLING TIMING CHART Red Light Signal Refer to Abnormal Heating or Cooling Operation Sections of this Manual O ff Internal Control Failure 1 Flash External Lockout 2 Flashes P.
21 CO M BU STION AIR I N TAK E EXHAU ST FLU E HOOD CONTRO L WIR E E N T R AN CE POW E R WIRE ENTR ANC E 7 7/8 7 5/16 SUC TIO N/LI QU ID PRE SSURE PO RTS BEH I ND COMPRE SSOR A C CES S PANEL HEA T EX C.
22 *PG15*****41A* WIRI NG DIAGRAM HIGH VOL T AGE! D A LL . M. F . ISCONNECT P OWER BEFORE SERVICING UL TIPLE POWER SOURC ES MA Y BE P R ESENT AILURE TO DO SO MA Y CAUSE PR OPERTY DAMAGE , PERSONAL I NJ U R Y OR DE A TH Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
23 *PG15*****41A* WIRING DIAGRAM HIGH VOL T AGE! D A LL . M. F . ISCONNECT P OWER BEFORE SERVICING UL TIPLE POWER SOURC ES MA Y BE P R ESENT AILURE TO DO SO MA Y CAUSE PR OPERTY DAMAGE , PERSONAL I NJ U R Y OR DE A TH EC ON ECON OMI ZER 8. FO R ECO NOMI ZER, RE MOVE P LUG FR OM E C O NO MIZER H ARNESS .
24 HIGH VOL T AGE! D A LL . M. F . ISCONNECT P OWER BEFORE SERVICING UL TIPLE POWER SOURC ES MA Y BE P R ESENT AILURE TO DO SO MA Y CAUSE PR OPERTY DAMAGE , PERSONAL I NJ U R Y OR DE A TH Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
25 HIGH VOL T AGE! D A LL . M. F . ISCONNECT P OWER BEFORE SERVICING UL TIPLE POWER SOURC ES MA Y BE P R ESENT AILURE TO DO SO MA Y CAUSE PR OPERTY DAMAGE , PERSONAL I NJ U R Y OR DE A TH Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
26 - NOTE: Roof overhang should be no more than 36". 3" MI N 12" MIN 12" MIN 36" MIN (FOR SERVICE ) . 48" MIN MINIMUM CLEARANCES RECOMMENDED FIL TER SIZES UNI T 2 T on 2 1/2 T on 3 T on 3 1/2 / 4 T on 5 T on Min.
27 BLOWER PERFORMANCE DA T A X = Outside of T emperature Rise Range - Not Recommended. NOTE: The shaded area indicates ranges in excess of maximum external static pressure allowable when heating. For satisfactory operation, external static pressure should not exceed 0.
28 P ACKAGE UNITS - DUAL FUEL & GAS HOMEOWNER’S ROUTINE MAINTENANCE RECOMMENDA TIONS We strongly recommend a bi-annual maintenance checkup be performed by a qualified service agency before the heating and cooling seasons begin.
Een belangrijk punt na aankoop van elk apparaat Goodman Mfg PG 15 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Goodman Mfg PG 15 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Goodman Mfg PG 15 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Goodman Mfg PG 15 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Goodman Mfg PG 15 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Goodman Mfg PG 15 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Goodman Mfg PG 15 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Goodman Mfg PG 15 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.